These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

349 related articles for article (PubMed ID: 31651057)

  • 1. A micro-computed tomographic assessment of root canal preparation with conventional and different rotary files in primary teeth and young permanent teeth.
    Esentürk G; Akkas E; Cubukcu E; Nagas E; Uyanik O; Cehreli ZC
    Int J Paediatr Dent; 2020 Mar; 30(2):202-208. PubMed ID: 31651057
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rotary Mtwo system versus manual K-file instruments: efficacy in preparing primary and permanent molar root canals.
    Azar MR; Mokhtare M
    Indian J Dent Res; 2011; 22(2):363. PubMed ID: 21891918
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the Self-Adjusting File system (SAF) for the instrumentation of primary molar root canals: a micro-computed tomographic study.
    Kaya E; Elbay M; Yiğit D
    Eur J Paediatr Dent; 2017 Jun; 18(2):105-110. PubMed ID: 28598180
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Microcomputed Assessment of Transportation, Centering Ratio, Canal Area, and Volume Increase after Single-file Rotary and Reciprocating Glide Path Instrumentation in Curved Root Canals: A Laboratory Study.
    Aydın ZU; Keskin NB; Özyürek T; Geneci F; Ocak M; Çelik HH
    J Endod; 2019 Jun; 45(6):791-796. PubMed ID: 30935620
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT.
    Yadav DBU; Varma RB; Kumar JS; Kumaran P; Xavier AM; Venugopal M; Thankappan N
    J Contemp Dent Pract; 2024 Mar; 25(3):250-259. PubMed ID: 38690699
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Shaping ability of hand, rotary and reciprocating files in primary teeth: a micro-CT study in vitro.
    Barasuol JC; Alcalde MP; Bortoluzzi EA; Duarte MAH; Cardoso M; Bolan M
    Eur Arch Paediatr Dent; 2021 Apr; 22(2):195-201. PubMed ID: 32346833
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative evaluation of root canal preparations of maxillary first molars with self-adjusting file, reciproc single file, and revo-s rotary file: A micro-computed tomography study.
    Ahmetoglu F; Keles A; Simsek N; Ocak MS; Yologlu S
    Scanning; 2015; 37(3):218-25. PubMed ID: 25737430
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of finishing instrumentation using NiTi hand files on volume, surface area and uninstrumented surfaces in C-shaped root canal systems.
    Amoroso-Silva P; Alcalde MP; Hungaro Duarte MA; De-Deus G; Ordinola-Zapata R; Freire LG; Cavenago BC; De Moraes IG
    Int Endod J; 2017 Jun; 50(6):604-611. PubMed ID: 27194509
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A reconstructed computerized tomographic comparison of Ni-Ti rotary GT files versus traditional instruments in canals shaped by novice operators.
    Gluskin AH; Brown DC; Buchanan LS
    Int Endod J; 2001 Sep; 34(6):476-84. PubMed ID: 11556516
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical Preparation Showed Superior Shaping Ability than Manual Technique in Primary Molars - A Micro-Computed Tomography Study.
    Hidalgo LRDC; Silva LABD; Leoni GB; Mazzi-Chaves JF; Carvalho EEDS; Consolaro A; Sousa-Neto MD
    Braz Dent J; 2017; 28(4):453-460. PubMed ID: 29160397
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hard-tissue debris accumulation created by conventional rotary versus self-adjusting file instrumentation in mesial root canal systems of mandibular molars.
    Paqué F; Al-Jadaa A; Kfir A
    Int Endod J; 2012 May; 45(5):413-8. PubMed ID: 22188277
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of two pediatric rotary file systems and hand instrumentation in primary molar: An ex vivo cone-beam computed tomographic study.
    Waly AS; Yamany I; Abbas HM; A Alsairafi MA; F Bazzaz RM; Bogari DF; Alhazzazi TY
    Niger J Clin Pract; 2021 Oct; 24(10):1492-1498. PubMed ID: 34657015
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Micro-computed tomographic evaluation of two single rotary glide path systems.
    van der Vyver PJ; Paleker F; Vorster M; de Wet FA
    Int Endod J; 2019 Mar; 52(3):352-358. PubMed ID: 30132925
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative evaluation of volumetric changes between two pediatric rotary files (Kedo-S plus, Kedo-SG blue) and manual files (hand K-files) during canal preparation of primary mandibular molars: an
    Suresh B; Jeevanandan G; Ravindran V; Vishwanathaiah S; Syed AA; Mokhtari N; Jaafari AHH; Dawood T; Maganur PC
    J Clin Pediatr Dent; 2024 Mar; 48(2):57-63. PubMed ID: 38548633
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microbiological assessment of root canals following use of rotary and manual instruments in primary molars.
    Subramaniam P; Tabrez TA; Babu KL
    J Clin Pediatr Dent; 2013; 38(2):123-7. PubMed ID: 24683774
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preparation of oval-shaped root canals in mandibular molars using nickel-titanium rotary instruments: a micro-computed tomography study.
    Paqué F; Balmer M; Attin T; Peters OA
    J Endod; 2010 Apr; 36(4):703-7. PubMed ID: 20307747
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Root canal preparation of mandibular molars with 3 nickel-titanium rotary instruments: a micro-computed tomographic study.
    Zhao D; Shen Y; Peng B; Haapasalo M
    J Endod; 2014 Nov; 40(11):1860-4. PubMed ID: 25205262
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computed Tomographic Evaluation of K3 Rotary and Stainless Steel K File Instrumentation in Primary Teeth.
    Selvakumar H; Kavitha S; Thomas E; Anadhan V; Vijayakumar R
    J Clin Diagn Res; 2016 Jan; 10(1):ZC05-8. PubMed ID: 26894166
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cone-beam computed tomography evaluation of shaping ability of kedo-S square and fanta AF™ baby rotary files compared to manual K-files in root canal preparation of primary anterior teeth.
    El-Desouky SS; El Fahl BN; Kabbash IA; Hadwa SM
    Clin Oral Investig; 2024 May; 28(6):340. PubMed ID: 38801642
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of Different Glide Path Files on Apical Debris Extrusion in Curved Root Canals.
    Gunes B; Yesildal Yeter K
    J Endod; 2018 Jul; 44(7):1191-1194. PubMed ID: 29884338
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.