These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

294 related articles for article (PubMed ID: 31651311)

  • 1. Mild hyperthermia by MR-guided focused ultrasound in an ex vivo model of osteolytic bone tumour: optimization of the spatio-temporal control of the delivered temperature.
    Guillemin PC; Gui L; Lorton O; Zilli T; Crowe LA; Desgranges S; Montet X; Terraz S; Miralbell R; Salomir R; Boudabbous S
    J Transl Med; 2019 Oct; 17(1):350. PubMed ID: 31651311
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
    Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
    Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array.
    Salgaonkar VA; Prakash P; Rieke V; Ozhinsky E; Plata J; Kurhanewicz J; Hsu IC; Diederich CJ
    Med Phys; 2014 Mar; 41(3):033301. PubMed ID: 24593742
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reduction of peak acoustic pressure and shaping of heated region by use of multifoci sonications in MR-guided high-intensity focused ultrasound mediated mild hyperthermia.
    Partanen A; Tillander M; Yarmolenko PS; Wood BJ; Dreher MR; Kohler MO
    Med Phys; 2013 Jan; 40(1):013301. PubMed ID: 23298120
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High intensity focused ultrasound induced in vivo large volume hyperthermia under 3D MRI temperature control.
    Tillander M; Hokland S; Koskela J; Dam H; Andersen NP; Pedersen M; Tanderup K; Ylihautala M; Köhler M
    Med Phys; 2016 Mar; 43(3):1539-49. PubMed ID: 26936737
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation.
    Chu W; Staruch RM; Pichardo S; Tillander M; Köhler MO; Huang Y; Ylihautala M; McGuffin M; Czarnota G; Hynynen K
    Int J Radiat Oncol Biol Phys; 2016 Jul; 95(4):1259-67. PubMed ID: 27209510
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Magnetic resonance imaging for the exploitation of bubble-enhanced heating by high-intensity focused ultrasound: a feasibility study in ex vivo liver.
    Elbes D; Denost Q; Robert B; Köhler MO; Tanter M; Bruno Q
    Ultrasound Med Biol; 2014 May; 40(5):956-64. PubMed ID: 24462160
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.
    Bing C; Staruch RM; Tillander M; Köhler MO; Mougenot C; Ylihautala M; Laetsch TW; Chopra R
    Int J Hyperthermia; 2016 Sep; 32(6):673-87. PubMed ID: 27210733
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hybrid ultrasound-MR guided HIFU treatment method with 3D motion compensation.
    Celicanin Z; Manasseh G; Petrusca L; Scheffler K; Auboiroux V; Crowe LA; Hyacinthe JN; Natsuaki Y; Santini F; Becker CD; Terraz S; Bieri O; Salomir R
    Magn Reson Med; 2018 May; 79(5):2511-2523. PubMed ID: 28944490
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Breath-hold MR-HIFU hyperthermia: phantom and
    Bing C; Cheng B; Staruch RM; Nofiele J; Wodzak Staruch M; Szczepanski D; Farrow-Gillespie A; Yang A; Laetsch TW; Chopra R
    Int J Hyperthermia; 2019; 36(1):1084-1097. PubMed ID: 31707872
    [No Abstract]   [Full Text] [Related]  

  • 11. Magnetic resonance-guided shielding of prefocal acoustic obstacles in focused ultrasound therapy: application to intercostal ablation in liver.
    Salomir R; Petrusca L; Auboiroux V; Muller A; Vargas MI; Morel DR; Goget T; Breguet R; Terraz S; Hopple J; Montet X; Becker CD; Viallon M
    Invest Radiol; 2013 Jun; 48(6):366-80. PubMed ID: 23344514
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mild hyperthermia with magnetic resonance-guided high-intensity focused ultrasound for applications in drug delivery.
    Partanen A; Yarmolenko PS; Viitala A; Appanaboyina S; Haemmerich D; Ranjan A; Jacobs G; Woods D; Enholm J; Wood BJ; Dreher MR
    Int J Hyperthermia; 2012; 28(4):320-36. PubMed ID: 22621734
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Model predictive control for MR-HIFU-mediated, uniform hyperthermia.
    Sebeke L; Deenen DA; Maljaars E; Heijman E; de Jager B; Heemels WPMH; Grüll H
    Int J Hyperthermia; 2019; 36(1):1040-1050. PubMed ID: 31621435
    [No Abstract]   [Full Text] [Related]  

  • 14. Feasibility of ultrasound tomography-guided localized mild hyperthermia using a ring transducer: Ex vivo and in silico studies.
    Pattyn A; Kratkiewicz K; Alijabbari N; Carson PL; Littrup P; Fowlkes JB; Duric N; Mehrmohammadi M
    Med Phys; 2022 Sep; 49(9):6120-6136. PubMed ID: 35759729
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
    Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
    Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In vivo optimisation study for multi-baseline MR-based thermometry in the context of hyperthermia using MR-guided high intensity focused ultrasound for head and neck applications.
    Pichardo S; Köhler M; Lee J; Hynnyen K
    Int J Hyperthermia; 2014 Dec; 30(8):579-92. PubMed ID: 25430989
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simulating thermal effects of MR-guided focused ultrasound in cortical bone and its surrounding tissue.
    Hudson TJ; Looi T; Pichardo S; Amaral J; Temple M; Drake JM; Waspe AC
    Med Phys; 2018 Feb; 45(2):506-519. PubMed ID: 29193144
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Spatio-temporal quantitative thermography of pre-focal interactions between high intensity focused ultrasound and the rib cage.
    Petrusca L; Salomir R; Manasseh G; Becker CD; Terraz S
    Int J Hyperthermia; 2015 Jun; 31(4):421-32. PubMed ID: 25753370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Interleaved water and fat MR thermometry for monitoring high intensity focused ultrasound ablation of bone lesions.
    Lena B; Bartels LW; Ferrer CJ; Moonen CTW; Viergever MA; Bos C
    Magn Reson Med; 2021 Nov; 86(5):2647-2655. PubMed ID: 34061390
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Volumetric hyperthermia delivery using the ExAblate Body MR-guided focused ultrasound system.
    Kim K; Gupta P; Narsinh K; Diederich CJ; Ozhinsky E
    Int J Hyperthermia; 2024; 41(1):2349080. PubMed ID: 38705588
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.