These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
273 related articles for article (PubMed ID: 31658890)
1. Microfluidic Paper-Based Analytical Devices for Colorimetric Detection of Lactoferrin. Kudo H; Maejima K; Hiruta Y; Citterio D SLAS Technol; 2020 Feb; 25(1):47-57. PubMed ID: 31658890 [TBL] [Abstract][Full Text] [Related]
2. Distance-Based Tear Lactoferrin Assay on Microfluidic Paper Device Using Interfacial Interactions on Surface-Modified Cellulose. Yamada K; Henares TG; Suzuki K; Citterio D ACS Appl Mater Interfaces; 2015 Nov; 7(44):24864-75. PubMed ID: 26488371 [TBL] [Abstract][Full Text] [Related]
3. Technical aspects and challenges of colorimetric detection with microfluidic paper-based analytical devices (μPADs) - A review. Morbioli GG; Mazzu-Nascimento T; Stockton AM; Carrilho E Anal Chim Acta; 2017 Jun; 970():1-22. PubMed ID: 28433054 [TBL] [Abstract][Full Text] [Related]
4. Nanozyme-Catalyzed Colorimetric Detection of the Total Antioxidant Capacity in Body Fluids by Paper-Based Microfluidic Chips. Wu H; Chen J; Lin P; Su Y; Li H; Xiao W; Peng J ACS Appl Mater Interfaces; 2024 Jul; 16(30):39857-39866. PubMed ID: 39018518 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of cellophane as platform for colorimetric assays on microfluidic analytical devices. Shigemori H; Maejima K; Shibata H; Hiruta Y; Citterio D Mikrochim Acta; 2023 Jan; 190(2):48. PubMed ID: 36622479 [TBL] [Abstract][Full Text] [Related]
7. "Dip-and-read" paper-based analytical devices using distance-based detection with color screening. Yamada K; Citterio D; Henry CS Lab Chip; 2018 May; 18(10):1485-1493. PubMed ID: 29693672 [TBL] [Abstract][Full Text] [Related]
8. Smartphone-Based Point-of-Care Microfluidic Platform Fabricated with a ZnO Nanorod Template for Colorimetric Virus Detection. Xia Y; Chen Y; Tang Y; Cheng G; Yu X; He H; Cao G; Lu H; Liu Z; Zheng SY ACS Sens; 2019 Dec; 4(12):3298-3307. PubMed ID: 31769284 [TBL] [Abstract][Full Text] [Related]
9. Paper-Plastic Hybrid Microfluidic Device for Smartphone-Based Colorimetric Analysis of Urine. Jalal UM; Jin GJ; Shim JS Anal Chem; 2017 Dec; 89(24):13160-13166. PubMed ID: 29131592 [TBL] [Abstract][Full Text] [Related]
10. Quantitative biomarker assay with microfluidic paper-based analytical devices. Li X; Tian J; Shen W Anal Bioanal Chem; 2010 Jan; 396(1):495-501. PubMed ID: 19838826 [TBL] [Abstract][Full Text] [Related]
11. Unveiling the potential of the capillary-driven microfluidic paper-based device integrated with smartphone-based for simultaneously colorimetric salivary ethanol and △ Srisomwat C; Bawornnithichaiyakul N; Khonyoung S; Tiyapongpattana W; Butcha S; Youngvises N; Chailapakul O Talanta; 2024 Dec; 280():126770. PubMed ID: 39208678 [TBL] [Abstract][Full Text] [Related]
12. Paper-Based Microfluidic Analytical Device Patterned by Label Printer for Point-of-Care Blood Glucose and Hematocrit Detection Using 3D-Printed Smartphone Cassette. Cai ZX; Jiang MZ; Chuang YJ; Kuo JN Sensors (Basel); 2024 Jul; 24(15):. PubMed ID: 39123836 [TBL] [Abstract][Full Text] [Related]
13. Three-Dimensional Paper-Based Microfluidic Analysis Device for Simultaneous Detection of Multiple Biomarkers with a Smartphone. Baek SH; Park C; Jeon J; Park S Biosensors (Basel); 2020 Nov; 10(11):. PubMed ID: 33233440 [TBL] [Abstract][Full Text] [Related]
14. A novel combination of quick response code and microfluidic paper-based analytical devices for rapid and quantitative detection. Wang T; Xu G; Wu W; Wang X; Chen X; Zhou S; You F Biomed Microdevices; 2018 Sep; 20(3):79. PubMed ID: 30187186 [TBL] [Abstract][Full Text] [Related]
15. An aptamer-based paper microfluidic device for the colorimetric determination of cocaine. Wang L; Musile G; McCord BR Electrophoresis; 2018 Feb; 39(3):470-475. PubMed ID: 28834613 [TBL] [Abstract][Full Text] [Related]
16. An antibody-free microfluidic paper-based analytical device for the determination of tear fluid lactoferrin by fluorescence sensitization of Tb3+. Yamada K; Takaki S; Komuro N; Suzuki K; Citterio D Analyst; 2014 Apr; 139(7):1637-43. PubMed ID: 24482793 [TBL] [Abstract][Full Text] [Related]
17. A colorimetric assay system for dopamine using microfluidic paper-based analytical devices. Liu C; Gomez FA; Miao Y; Cui P; Lee W Talanta; 2019 Mar; 194():171-176. PubMed ID: 30609518 [TBL] [Abstract][Full Text] [Related]
18. Inkjet printed microfluidic paper-based analytical device (μPAD) for glucose colorimetric detection in artificial urine. Zhang H; Smith E; Zhang W; Zhou A Biomed Microdevices; 2019 Jun; 21(3):48. PubMed ID: 31183565 [TBL] [Abstract][Full Text] [Related]
19. Determination of norfloxacin residues in foods by exploiting the coffee-ring effect and paper-based microfluidics device coupling with smartphone-based detection. Trofimchuk E; Nilghaz A; Sun S; Lu X J Food Sci; 2020 Mar; 85(3):736-743. PubMed ID: 32017096 [TBL] [Abstract][Full Text] [Related]
20. 3D Multilayered paper- and thread/paper-based microfluidic devices for bioassays. Neris NM; Guevara RD; Gonzalez A; Gomez FA Electrophoresis; 2019 Jan; 40(2):296-303. PubMed ID: 30383293 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]