These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 31660265)

  • 1. Unfold: an integrated toolbox for overlap correction, non-linear modeling, and regression-based EEG analysis.
    Ehinger BV; Dimigen O
    PeerJ; 2019; 7():e7838. PubMed ID: 31660265
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Regression-based analysis of combined EEG and eye-tracking data: Theory and applications.
    Dimigen O; Ehinger BV
    J Vis; 2021 Jan; 21(1):3. PubMed ID: 33410892
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Decision Decoding ToolBOX (DDTBOX) - A Multivariate Pattern Analysis Toolbox for Event-Related Potentials.
    Bode S; Feuerriegel D; Bennett D; Alday PM
    Neuroinformatics; 2019 Jan; 17(1):27-42. PubMed ID: 29721680
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Recording human electrocorticographic (ECoG) signals for neuroscientific research and real-time functional cortical mapping.
    Hill NJ; Gupta D; Brunner P; Gunduz A; Adamo MA; Ritaccio A; Schalk G
    J Vis Exp; 2012 Jun; (64):. PubMed ID: 22782131
    [TBL] [Abstract][Full Text] [Related]  

  • 5. ERPLAB: an open-source toolbox for the analysis of event-related potentials.
    Lopez-Calderon J; Luck SJ
    Front Hum Neurosci; 2014; 8():213. PubMed ID: 24782741
    [TBL] [Abstract][Full Text] [Related]  

  • 6. EEG-Annotate: Automated identification and labeling of events in continuous signals with applications to EEG.
    Su KM; Hairston WD; Robbins K
    J Neurosci Methods; 2018 Jan; 293():359-374. PubMed ID: 29061343
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Regression-based estimation of ERP waveforms: I. The rERP framework.
    Smith NJ; Kutas M
    Psychophysiology; 2015 Feb; 52(2):157-68. PubMed ID: 25141770
    [TBL] [Abstract][Full Text] [Related]  

  • 8. WildLab: A naturalistic free viewing experiment reveals previously unknown electroencephalography signatures of face processing.
    Gert AL; Ehinger BV; Timm S; Kietzmann TC; König P
    Eur J Neurosci; 2022 Dec; 56(11):6022-6038. PubMed ID: 36113866
    [TBL] [Abstract][Full Text] [Related]  

  • 9. ERP Reliability Analysis (ERA) Toolbox: An open-source toolbox for analyzing the reliability of event-related brain potentials.
    Clayson PE; Miller GA
    Int J Psychophysiol; 2017 Jan; 111():68-79. PubMed ID: 27769878
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Source-Modeling Auditory Processes of EEG Data Using EEGLAB and Brainstorm.
    Stropahl M; Bauer AR; Debener S; Bleichner MG
    Front Neurosci; 2018; 12():309. PubMed ID: 29867321
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Local spatial analysis: an easy-to-use adaptive spatial EEG filter.
    Bufacchi RJ; Magri C; Novembre G; Iannetti GD
    J Neurophysiol; 2021 Feb; 125(2):509-521. PubMed ID: 33174497
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automated EEG mega-analysis II: Cognitive aspects of event related features.
    Bigdely-Shamlo N; Touryan J; Ojeda A; Kothe C; Mullen T; Robbins K
    Neuroimage; 2020 Feb; 207():116054. PubMed ID: 31491523
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Regression-based estimation of ERP waveforms: II. Nonlinear effects, overlap correction, and practical considerations.
    Smith NJ; Kutas M
    Psychophysiology; 2015 Feb; 52(2):169-81. PubMed ID: 25195691
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis and visualization of single-trial event-related potentials.
    Jung TP; Makeig S; Westerfield M; Townsend J; Courchesne E; Sejnowski TJ
    Hum Brain Mapp; 2001 Nov; 14(3):166-85. PubMed ID: 11559961
    [TBL] [Abstract][Full Text] [Related]  

  • 15. EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis.
    Delorme A; Makeig S
    J Neurosci Methods; 2004 Mar; 134(1):9-21. PubMed ID: 15102499
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The PhysIO Toolbox for Modeling Physiological Noise in fMRI Data.
    Kasper L; Bollmann S; Diaconescu AO; Hutton C; Heinzle J; Iglesias S; Hauser TU; Sebold M; Manjaly ZM; Pruessmann KP; Stephan KE
    J Neurosci Methods; 2017 Jan; 276():56-72. PubMed ID: 27832957
    [TBL] [Abstract][Full Text] [Related]  

  • 17. From ERPs to MVPA Using the Amsterdam Decoding and Modeling Toolbox (ADAM).
    Fahrenfort JJ; van Driel J; van Gaal S; Olivers CNL
    Front Neurosci; 2018; 12():368. PubMed ID: 30018529
    [TBL] [Abstract][Full Text] [Related]  

  • 18. TMSEEG: A MATLAB-Based Graphical User Interface for Processing Electrophysiological Signals during Transcranial Magnetic Stimulation.
    Atluri S; Frehlich M; Mei Y; Garcia Dominguez L; Rogasch NC; Wong W; Daskalakis ZJ; Farzan F
    Front Neural Circuits; 2016; 10():78. PubMed ID: 27774054
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biases in BCI experiments: Do we really need to balance stimulus properties across categories?
    La Fisca L; Vandenbulcke V; Wauthia E; Miceli A; Simoes Loureiro I; Ris L; Lefebvre L; Gosselin B; Pernet CR
    Front Comput Neurosci; 2022; 16():900571. PubMed ID: 36507305
    [TBL] [Abstract][Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 11.