1370 related articles for article (PubMed ID: 31661559)
1. Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.
Padilla-Cabal F; Alejandro Fragoso J; Franz Resch A; Georg D; Fuchs H
Med Phys; 2020 Jan; 47(1):223-233. PubMed ID: 31661559
[TBL] [Abstract][Full Text] [Related]
2. A pencil beam algorithm for magnetic resonance image-guided proton therapy.
Padilla-Cabal F; Georg D; Fuchs H
Med Phys; 2018 May; 45(5):2195-2204. PubMed ID: 29532490
[TBL] [Abstract][Full Text] [Related]
3. Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields.
Padilla-Cabal F; Kuess P; Georg D; Palmans H; Fetty L; Fuchs H
Med Phys; 2019 Jul; 46(7):3278-3284. PubMed ID: 31055847
[TBL] [Abstract][Full Text] [Related]
4. Technical Note: Experimental verification of magnetic field-induced beam deflection and Bragg peak displacement for MR-integrated proton therapy.
Schellhammer SM; Gantz S; Lühr A; Oborn BM; Bussmann M; Hoffmann AL
Med Phys; 2018 Jul; 45(7):3429-3434. PubMed ID: 29763970
[TBL] [Abstract][Full Text] [Related]
5. Dose- rather than fluence-averaged LET should be used as a single-parameter descriptor of proton beam quality for radiochromic film dosimetry.
Resch AF; Heyes PD; Fuchs H; Bassler N; Georg D; Palmans H
Med Phys; 2020 Jun; 47(5):2289-2299. PubMed ID: 32166764
[TBL] [Abstract][Full Text] [Related]
6. An initial systematic study of the linear energy transfer distributions of a proton beam under a transverse magnetic field.
Fujii Y; Ueda H; Umegaki K; Matsuura T
Med Phys; 2022 Mar; 49(3):1839-1852. PubMed ID: 35124798
[TBL] [Abstract][Full Text] [Related]
7. Dosimetric evaluation of a commercial proton spot scanning Monte-Carlo dose algorithm: comparisons against measurements and simulations.
Saini J; Maes D; Egan A; Bowen SR; St James S; Janson M; Wong T; Bloch C
Phys Med Biol; 2017 Sep; 62(19):7659-7681. PubMed ID: 28749373
[TBL] [Abstract][Full Text] [Related]
8. Commissioning a beam line for MR-guided particle therapy assisted by in silico methods.
Fuchs H; Padilla-Cabal F; Oborn BM; Georg D
Med Phys; 2023 Feb; 50(2):1019-1028. PubMed ID: 36504399
[TBL] [Abstract][Full Text] [Related]
9. Proton dosimetry in a magnetic field: Measurement and calculation of magnetic field correction factors for a plane-parallel ionization chamber.
Gebauer B; Baumann KS; Fuchs H; Georg D; Oborn BM; Looe HK; Lühr A
Med Phys; 2024 Mar; 51(3):2293-2305. PubMed ID: 37898105
[TBL] [Abstract][Full Text] [Related]
10. Development of an extended Macro Monte Carlo method for efficient and accurate dose calculation in magnetic fields.
Kueng R; Guyer G; Volken W; Frei D; Stabel F; Stampanoni MFM; Manser P; Fix MK
Med Phys; 2020 Dec; 47(12):6519-6530. PubMed ID: 33075168
[TBL] [Abstract][Full Text] [Related]
11. Magnetic field effects on particle beams and their implications for dose calculation in MR-guided particle therapy.
Fuchs H; Moser P; Gröschl M; Georg D
Med Phys; 2017 Mar; 44(3):1149-1156. PubMed ID: 28090633
[TBL] [Abstract][Full Text] [Related]
12. A linear relationship for the LET-dependence of Gafchromic EBT3 film in spot-scanning proton therapy.
Anderson SE; Grams MP; Wan Chan Tseung H; Furutani KM; Beltran CJ
Phys Med Biol; 2019 Mar; 64(5):055015. PubMed ID: 30673655
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of GATE-RTion (GATE/Geant4) Monte Carlo simulation settings for proton pencil beam scanning quality assurance.
Winterhalter C; Taylor M; Boersma D; Elia A; Guatelli S; Mackay R; Kirkby K; Maigne L; Ivanchenko V; Resch AF; Sarrut D; Sitch P; Vidal M; Grevillot L; Aitkenhead A
Med Phys; 2020 Nov; 47(11):5817-5828. PubMed ID: 32967037
[TBL] [Abstract][Full Text] [Related]
14. Proton beam deflection in MRI fields: Implications for MRI-guided proton therapy.
Oborn BM; Dowdell S; Metcalfe PE; Crozier S; Mohan R; Keall PJ
Med Phys; 2015 May; 42(5):2113-24. PubMed ID: 25979006
[TBL] [Abstract][Full Text] [Related]
15. Proton beam behavior in a parallel configured MRI-proton therapy hybrid: Effects of time-varying gradient magnetic fields.
Santos DM; Wachowicz K; Burke B; Fallone BG
Med Phys; 2019 Feb; 46(2):822-838. PubMed ID: 30488968
[TBL] [Abstract][Full Text] [Related]
16. Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy.
Testa M; Schümann J; Lu HM; Shin J; Faddegon B; Perl J; Paganetti H
Med Phys; 2013 Dec; 40(12):121719. PubMed ID: 24320505
[TBL] [Abstract][Full Text] [Related]
17. An analytical dose-averaged LET calculation algorithm considering the off-axis LET enhancement by secondary protons for spot-scanning proton therapy.
Hirayama S; Matsuura T; Ueda H; Fujii Y; Fujii T; Takao S; Miyamoto N; Shimizu S; Fujimoto R; Umegaki K; Shirato H
Med Phys; 2018 Jul; 45(7):3404-3416. PubMed ID: 29788552
[TBL] [Abstract][Full Text] [Related]
18. Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy.
Mirandola A; Molinelli S; Vilches Freixas G; Mairani A; Gallio E; Panizza D; Russo S; Ciocca M; Donetti M; Magro G; Giordanengo S; Orecchia R
Med Phys; 2015 Sep; 42(9):5287-300. PubMed ID: 26328978
[TBL] [Abstract][Full Text] [Related]
19. Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation.
Faddegon BA; Shin J; Castenada CM; Ramos-Méndez J; Daftari IK
Med Phys; 2015 Jul; 42(7):4199-210. PubMed ID: 26133619
[TBL] [Abstract][Full Text] [Related]
20. Development and validation of an optimal GATE model for proton pencil-beam scanning delivery.
Asadi A; Akhavanallaf A; Hosseini SA; Vosoughi N; Zaidi H
Z Med Phys; 2023 Nov; 33(4):591-600. PubMed ID: 36424313
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]