These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 31664269)

  • 1. Accuracy of Clasps Fabricated with Three Different CAD/CAM Technologies: Casting, Milling, and Selective Laser Sintering.
    Tasaka A; Kato Y; Odaka K; Matsunaga S; Goto TK; Abe S; Yamashita S
    Int J Prosthodont; 2019; 32(6):526-529. PubMed ID: 31664269
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fitness and retentive force of cobalt-chromium alloy clasps fabricated with repeated laser sintering and milling.
    Torii M; Nakata T; Takahashi K; Kawamura N; Shimpo H; Ohkubo C
    J Prosthodont Res; 2018 Jul; 62(3):342-346. PubMed ID: 29428170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clasp fabrication using one-process molding by repeated laser sintering and high-speed milling.
    Nakata T; Shimpo H; Ohkubo C
    J Prosthodont Res; 2017 Jul; 61(3):276-282. PubMed ID: 27825561
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Titanium clasp fabricated by selective laser melting, CNC milling, and conventional casting: a comparative in vitro study.
    Tan FB; Song JL; Wang C; Fan YB; Dai HW
    J Prosthodont Res; 2019 Jan; 63(1):58-65. PubMed ID: 30309743
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.
    Papadiochou S; Pissiotis AL
    J Prosthet Dent; 2018 Apr; 119(4):545-551. PubMed ID: 28967399
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering.
    Tasaka A; Shimizu T; Kato Y; Okano H; Ida Y; Higuchi S; Yamashita S
    J Prosthodont Res; 2020 Apr; 64(2):224-230. PubMed ID: 31466919
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of CAD-CAM-fabricated removable partial dentures.
    Arnold C; Hey J; Schweyen R; Setz JM
    J Prosthet Dent; 2018 Apr; 119(4):586-592. PubMed ID: 28709674
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems.
    Kim EH; Lee DH; Kwon SM; Kwon TY
    J Prosthet Dent; 2017 Mar; 117(3):393-399. PubMed ID: 27677219
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Laboratory efficiency of additive manufacturing for removable denture frameworks: A literature-based review.
    Suzuki Y; Shimizu S; Waki T; Shimpo H; Ohkubo C
    Dent Mater J; 2021 Mar; 40(2):265-271. PubMed ID: 33361665
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Selective Laser Sintering versus Selective Laser Melting and Computer Aided Design - Computer Aided Manufacturing in Double Crowns Retention.
    Goguta L; Lungeanu D; Negru R; Birdeanu M; Jivanescu A; Sinescu C
    J Prosthodont Res; 2021 Aug; 65(3):371-378. PubMed ID: 32981911
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of manufacturing techniques on the marginal and internal fit of cobalt-chromium implant-supported multiunit frameworks.
    Akçin ET; Güncü MB; Aktaş G; Aslan Y
    J Prosthet Dent; 2018 Nov; 120(5):715-720. PubMed ID: 30017153
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Obturator fabrication incorporating computer-aided design and 3-dimensional printing technology: A clinical report.
    Soltanzadeh P; Su JM; Habibabadi SR; Kattadiyil MT
    J Prosthet Dent; 2019 Apr; 121(4):694-697. PubMed ID: 30711293
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique.
    Neves FD; Prado CJ; Prudente MS; Carneiro TA; Zancopé K; Davi LR; Mendonça G; Cooper LF; Soares CJ
    J Prosthet Dent; 2014 Nov; 112(5):1134-40. PubMed ID: 24969409
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Influence of repeated firings on marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic restorations fabricated with different techniques.
    Önöral Ö; Ulusoy M; Seker E; Etikan İ
    J Prosthet Dent; 2018 Sep; 120(3):415-420. PubMed ID: 29627208
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the Marginal Fit of Cobalt-Chromium Metal-Ceramic Crowns Fabricated by CAD/CAM Techniques and Conventional Methods at Three Production Stages.
    Real-Voltas F; Romano-Cardozo E; Figueras-Alvarez O; Brufau-de Barbera M; Cabratosa-Termes J
    Int J Prosthodont; 2017; 30(3):304–305. PubMed ID: 28319213
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns.
    Tamac E; Toksavul S; Toman M
    J Prosthet Dent; 2014 Oct; 112(4):909-13. PubMed ID: 24819532
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of fabrication stages and cementation on the marginal fit of CAD-CAM monolithic zirconia crowns.
    Kale E; Yilmaz B; Seker E; Özcelik TB
    J Prosthet Dent; 2017 Dec; 118(6):736-741. PubMed ID: 28434679
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of marginal/internal fit of chrome-cobalt crowns: Direct laser metal sintering versus computer-aided design and computer-aided manufacturing.
    Gunsoy S; Ulusoy M
    Niger J Clin Pract; 2016; 19(5):636-44. PubMed ID: 27538553
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Corrosion resistance assessment of Co-Cr alloy frameworks fabricated by CAD/CAM milling, laser sintering, and casting methods.
    Tuna SH; Özçiçek Pekmez N; Kürkçüoğlu I
    J Prosthet Dent; 2015 Nov; 114(5):725-34. PubMed ID: 26187104
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of surface adaptation of complete denture bases fabricated using milling, material jetting, selective laser sintering, digital light processing, and conventional injection molding.
    Schubert O; Edelhoff D; Erdelt KJ; Nold E; Güth JF
    Int J Comput Dent; 2022 Jul; 25(2):151-159. PubMed ID: 35060369
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.