These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 31666550)

  • 1. Precision and safety of Multilevel Cervical Transpedicular Screw Fixation with 3D Patient-Specific Guides; A Cadaveric Study.
    Sallent A; Ramírez M; Catalá J; Rodríguez-Baeza A; Bagó J; de Albert M; Vélez R
    Sci Rep; 2019 Oct; 9(1):15686. PubMed ID: 31666550
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques.
    Ludwig SC; Kramer DL; Balderston RA; Vaccaro AR; Foley KF; Albert TJ
    Spine (Phila Pa 1976); 2000 Jul; 25(13):1655-67. PubMed ID: 10870141
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Generating patient-matched 3D-printed pedicle screw and laminectomy drill guides from Cone Beam CT images: Studies in ovine and porcine cadavers.
    Kanawati A; Constantinidis A; Williams Z; O'Brien R; Reynolds T
    Med Phys; 2022 Jul; 49(7):4642-4652. PubMed ID: 35445429
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Comparative study between 3D guide plate assisted and free-hand insertion of anterior cervical transpedicular screw].
    Li J; Zhao LJ; Zheng MZ; Gan KF; Chen YL; Feng ZX; Pan LX; Xu JX; Fan TD; Chen JY; Zhao FD
    Zhongguo Gu Shang; 2021 Jan; 34(1):45-50. PubMed ID: 33666019
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Application of a novel 3D drill template for cervical pedicle screw tunnel design: a cadaveric study.
    Yu Z; Zhang G; Chen X; Chen X; Wu C; Lin Y; Huang W; Lin H
    Eur Spine J; 2017 Sep; 26(9):2348-2356. PubMed ID: 28601990
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Paravertebral foramen screw fixation for posterior cervical spine fusion: biomechanical study and description of a novel technique.
    Maki S; Aramomi M; Matsuura Y; Furuya T; Ota M; Iijima Y; Saito J; Suzuki T; Mannoji C; Takahashi K; Yamazaki M; Koda M
    J Neurosurg Spine; 2017 Oct; 27(4):415-420. PubMed ID: 28498072
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of a patient-specific 3D printed drill guide for placement of cervical transpedicular screws.
    Hamilton-Bennett SE; Oxley B; Behr S
    Vet Surg; 2018 Feb; 47(2):236-242. PubMed ID: 29064584
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study.
    Luo J; Wu C; Huang Z; Pan Z; Li Z; Zhong J; Chen Y; Han Z; Cao K
    Arch Orthop Trauma Surg; 2017 Apr; 137(4):517-522. PubMed ID: 28236185
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of Patient-Specific, 3D-Printed Laminofacetal Based Trajectory-Guide for Pedicle Screw Placement in Subaxial Cervical and Thoracic Spine.
    Kashyap A; Karim A; Arora S; Singh K; Jha S; Maini L
    Neurol India; 2023; 71(2):260-266. PubMed ID: 37148049
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of 3D fluoro-navigated anterior transpedicular screws in the subaxial cervical spine: an experimental study on human specimens.
    Bredow J; Meyer C; Siedek F; Neiss WF; Löhrer L; Müller LP; Eysel P; Stein G
    Eur Spine J; 2017 Nov; 26(11):2934-2940. PubMed ID: 28752244
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computed tomography assessment of lateral pedicle wall perforation by free-hand subaxial cervical pedicle screw placement.
    Wang Y; Xie J; Yang Z; Zhao Z; Zhang Y; Li T; Liu L
    Arch Orthop Trauma Surg; 2013 Jul; 133(7):901-9. PubMed ID: 23632781
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Anatomic consideration of C2 pedicle screw placement.
    Ebraheim N; Rollins JR; Xu R; Jackson WT
    Spine (Phila Pa 1976); 1996 Mar; 21(6):691-5. PubMed ID: 8882690
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anatomic consideration of transpedicular screw placement in the cervical spine. An analysis of two approaches.
    Miller RM; Ebraheim NA; Xu R; Yeasting RA
    Spine (Phila Pa 1976); 1996 Oct; 21(20):2317-22. PubMed ID: 8915065
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.
    Sakamoto T; Neo M; Nakamura T
    Spine (Phila Pa 1976); 2004 Nov; 29(22):2510-4; discussion 2515. PubMed ID: 15543062
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of Patient-Specific 3D-Printed Drill Guides for Pedicle and Lateral Mass Screw Insertion: An Analysis of 76 Cervical and Thoracic Screw Trajectories.
    Pijpker PAJ; Kraeima J; Witjes MJH; Oterdoom DLM; Vergeer RA; Coppes MH; Groen RJM; Kuijlen JMA
    Spine (Phila Pa 1976); 2021 Feb; 46(3):160-168. PubMed ID: 33093310
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design and basic research on accuracy of a novel individualized three-dimensional printed navigation template in atlantoaxial pedicle screw placement.
    Chen XL; Xie YF; Li JX; Wu W; Li GN; Hu HJ; Wang XY; Meng ZJ; Wen YF; Huang WH
    PLoS One; 2019; 14(4):e0214460. PubMed ID: 30939170
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design and application of a novel patient-specific 3D printed drill navigational guiding template in percutaneous thoracolumbar pedicle screw fixation: A cadaveric study.
    Li Z; Xu D; Li F; Liu M; Xu G; Yang M
    J Clin Neurosci; 2020 Mar; 73():294-298. PubMed ID: 32035796
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.
    Kawaguchi Y; Nakano M; Yasuda T; Seki S; Hori T; Kimura T
    Spine (Phila Pa 1976); 2012 Nov; 37(23):1983-8. PubMed ID: 22531473
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Development of Novel 2-in-1 Patient-Specific, 3D-Printed Laminectomy Guides with Integrated Pedicle Screw Drill Guides.
    Kanawati A; Rodrigues Fernandes RJ; Gee A; Urquhart J; Siddiqi F; Gurr K; Bailey CS; Rasoulinejad P
    World Neurosurg; 2021 May; 149():e821-e827. PubMed ID: 33540103
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Anterior transpedicular screw fixation of cervical spine: Is it safe? Morphological feasibility, technical properties, and accuracy of manual insertion.
    Koktekir E; Toktas ZO; Seker A; Akakin A; Konya D; Kilic T
    J Neurosurg Spine; 2015 Jun; 22(6):596-604. PubMed ID: 25815805
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.