246 related articles for article (PubMed ID: 31669299)
1. Does a Sway-Based Mobile Application Predict Future Falls in People With Parkinson Disease?
Fiems CL; Miller SA; Buchanan N; Knowles E; Larson E; Snow R; Moore ES
Arch Phys Med Rehabil; 2020 Mar; 101(3):472-478. PubMed ID: 31669299
[TBL] [Abstract][Full Text] [Related]
2. Comparison of the Fullerton Advanced Balance Scale, Mini-BESTest, and Berg Balance Scale to Predict Falls in Parkinson Disease.
Schlenstedt C; Brombacher S; Hartwigsen G; Weisser B; Möller B; Deuschl G
Phys Ther; 2016 Apr; 96(4):494-501. PubMed ID: 26381806
[TBL] [Abstract][Full Text] [Related]
3. Functional gait assessment and balance evaluation system test: reliability, validity, sensitivity, and specificity for identifying individuals with Parkinson disease who fall.
Leddy AL; Crowner BE; Earhart GM
Phys Ther; 2011 Jan; 91(1):102-13. PubMed ID: 21071506
[TBL] [Abstract][Full Text] [Related]
4. Can postural instability tests improve the prediction of future falls in people with Parkinson's disease beyond knowing existing fall history?
Jacobs JV; Earhart GM; McNeely ME
J Neurol; 2016 Jan; 263(1):133-9. PubMed ID: 26530511
[TBL] [Abstract][Full Text] [Related]
5. Insights Into the Mini-BESTest Scoring System: Comparison of 6 Different Structural Models.
Godi M; Arcolin I; Leavy B; Giardini M; Corna S; Franzén E
Phys Ther; 2021 Oct; 101(10):. PubMed ID: 34339510
[TBL] [Abstract][Full Text] [Related]
6. Use of a Short-Form Balance Confidence Scale to Predict Future Recurrent Falls in People With Parkinson Disease.
Cole MH; Rippey J; Naughton GA; Silburn PA
Arch Phys Med Rehabil; 2016 Jan; 97(1):152-6. PubMed ID: 26319299
[TBL] [Abstract][Full Text] [Related]
7. Reliability, Validity, and Ability to Identify Fall Status of the Balance Evaluation Systems Test, Mini-Balance Evaluation Systems Test, and Brief-Balance Evaluation Systems Test in Older People Living in the Community.
Marques A; Almeida S; Carvalho J; Cruz J; Oliveira A; Jácome C
Arch Phys Med Rehabil; 2016 Dec; 97(12):2166-2173.e1. PubMed ID: 27497826
[TBL] [Abstract][Full Text] [Related]
8. Comparative utility of the BESTest, mini-BESTest, and brief-BESTest for predicting falls in individuals with Parkinson disease: a cohort study.
Duncan RP; Leddy AL; Cavanaugh JT; Dibble LE; Ellis TD; Ford MP; Foreman KB; Earhart GM
Phys Ther; 2013 Apr; 93(4):542-50. PubMed ID: 23174567
[TBL] [Abstract][Full Text] [Related]
9. Predicting falls in individuals with Parkinson disease: a reconsideration of clinical balance measures.
Dibble LE; Lange M
J Neurol Phys Ther; 2006 Jun; 30(2):60-7. PubMed ID: 16796770
[TBL] [Abstract][Full Text] [Related]
10. The mini-BESTest can predict parkinsonian recurrent fallers: a 6-month prospective study.
Mak MK; Auyeung MM
J Rehabil Med; 2013 Jun; 45(6):565-71. PubMed ID: 23673397
[TBL] [Abstract][Full Text] [Related]
11. The Mini-Balance Evaluation Systems Test (Mini-BESTest) Demonstrates Higher Accuracy in Identifying Older Adult Participants With History of Falls Than Do the BESTest, Berg Balance Scale, or Timed Up and Go Test.
Yingyongyudha A; Saengsirisuwan V; Panichaporn W; Boonsinsukh R
J Geriatr Phys Ther; 2016; 39(2):64-70. PubMed ID: 25794308
[TBL] [Abstract][Full Text] [Related]
12. The Mini-BESTest is an independent predictor of falls in Parkinson Disease.
Lopes LKR; Scianni AA; Lima LO; de Carvalho Lana R; Rodrigues-De-Paula F
Braz J Phys Ther; 2020; 24(5):433-440. PubMed ID: 31377123
[TBL] [Abstract][Full Text] [Related]
13. Utility of the Mini-BESTest, BESTest, and BESTest sections for balance assessments in individuals with Parkinson disease.
Leddy AL; Crowner BE; Earhart GM
J Neurol Phys Ther; 2011 Jun; 35(2):90-7. PubMed ID: 21934364
[TBL] [Abstract][Full Text] [Related]
14. Comparison of Self-report and Performance-Based Balance Measures for Predicting Recurrent Falls in People With Parkinson Disease: Cohort Study.
Almeida LR; Valenca GT; Negreiros NN; Pinto EB; Oliveira-Filho J
Phys Ther; 2016 Jul; 96(7):1074-84. PubMed ID: 26821572
[TBL] [Abstract][Full Text] [Related]
15. Validity, Reliability, and Ability to Identify Fall Status of the Berg Balance Scale, BESTest, Mini-BESTest, and Brief-BESTest in Patients With COPD.
Jácome C; Cruz J; Oliveira A; Marques A
Phys Ther; 2016 Nov; 96(11):1807-1815. PubMed ID: 27081201
[TBL] [Abstract][Full Text] [Related]
16. Predicting falls within the elderly community: comparison of postural sway, reaction time, the Berg balance scale and the Activities-specific Balance Confidence (ABC) scale for comparing fallers and non-fallers.
Lajoie Y; Gallagher SP
Arch Gerontol Geriatr; 2004; 38(1):11-26. PubMed ID: 14599700
[TBL] [Abstract][Full Text] [Related]
17. Balance measured by the sway balance smart-device application does not discriminate between older persons with and without a fall history.
Vincenzo JL; Glenn JM; Gray SM; Gray M
Aging Clin Exp Res; 2016 Aug; 28(4):679-86. PubMed ID: 26458942
[TBL] [Abstract][Full Text] [Related]
18. Detecting and predicting balance decline in Parkinson disease: a prospective cohort study.
Duncan RP; Leddy AL; Cavanaugh JT; Dibble LE; Ellis TD; Ford MP; Foreman KB; Earhart GM
J Parkinsons Dis; 2015; 5(1):131-9. PubMed ID: 25514984
[TBL] [Abstract][Full Text] [Related]
19. Comparing the Fullerton Advanced Balance Scale with the Mini-BESTest and Berg Balance Scale to assess postural control in patients with Parkinson disease.
Schlenstedt C; Brombacher S; Hartwigsen G; Weisser B; Möller B; Deuschl G
Arch Phys Med Rehabil; 2015 Feb; 96(2):218-25. PubMed ID: 25261718
[TBL] [Abstract][Full Text] [Related]
20. Clinical and stabilometric measures predicting falls in Parkinson disease/parkinsonisms.
Gervasoni E; Cattaneo D; Messina P; Casati E; Montesano A; Bianchi E; Beghi E
Acta Neurol Scand; 2015 Oct; 132(4):235-41. PubMed ID: 25690532
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]