These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 3167931)

  • 21. 3-D computational analysis of the stress distribution on the leaflets after edge-to-edge repair of mitral regurgitation.
    Votta E; Maisano F; Soncini M; Redaelli A; Montevecchi FM; Alfieri O
    J Heart Valve Dis; 2002 Nov; 11(6):810-22. PubMed ID: 12479282
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Stent and Leaflet Stresses in 29-mm Second-Generation Balloon-Expandable Transcatheter Aortic Valve.
    Xuan Y; Krishnan K; Ye J; Dvir D; Guccione JM; Ge L; Tseng EE
    Ann Thorac Surg; 2017 Sep; 104(3):773-781. PubMed ID: 28410636
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Is zero-pressure fixation of bioprosthetic valves truly stress free?
    Vesely I; Lozon A; Talman E
    J Thorac Cardiovasc Surg; 1993 Aug; 106(2):288-98. PubMed ID: 8341070
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Experimental technique of measuring dynamic fluid shear stress on the aortic surface of the aortic valve leaflet.
    Yap CH; Saikrishnan N; Tamilselvan G; Yoganathan AP
    J Biomech Eng; 2011 Jun; 133(6):061007. PubMed ID: 21744927
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Endothelial cell orientation on aortic valve leaflets.
    Deck JD
    Cardiovasc Res; 1986 Oct; 20(10):760-7. PubMed ID: 3791342
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Age-related changes in the aortic valve affect leaflet stress distributions: implications for aortic valve degeneration.
    Singh R; Strom JA; Ondrovic L; Joseph B; VanAuker MD
    J Heart Valve Dis; 2008 May; 17(3):290-8; discussion 299. PubMed ID: 18592926
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Design and dynamic variations of aortic valve leaflets in vivo.
    Thubrikar M; Piepgrass WC; Shaner TW; Nolan SP
    Surg Forum; 1979; 30():241-3. PubMed ID: 538608
    [No Abstract]   [Full Text] [Related]  

  • 29. Structural analysis of a stented pericardial heart valve with leaflets mounted externally.
    Avanzini A; Battini D
    Proc Inst Mech Eng H; 2014 Oct; 228(10):985-95. PubMed ID: 25252695
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Cyclic pressure and angiotensin II influence the biomechanical properties of aortic valves.
    Myles V; Liao J; Warnock JN
    J Biomech Eng; 2014 Jan; 136(1):011011. PubMed ID: 24240552
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Subject-specific multiscale modeling of aortic valve biomechanics.
    Rossini G; Caimi A; Redaelli A; Votta E
    Biomech Model Mechanobiol; 2021 Jun; 20(3):1031-1046. PubMed ID: 33792805
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Analysis of the design and dynamics of aortic bioprostheses in vivo.
    Thubrikar M; Skinner JR; Aouad J; Finkelmeier BA; Nolan SP
    J Thorac Cardiovasc Surg; 1982 Aug; 84(2):282-90. PubMed ID: 7098513
    [TBL] [Abstract][Full Text] [Related]  

  • 33. St Jude Epic heart valve bioprostheses versus native human and porcine aortic valves - comparison of mechanical properties.
    Kalejs M; Stradins P; Lacis R; Ozolanta I; Pavars J; Kasyanov V
    Interact Cardiovasc Thorac Surg; 2009 May; 8(5):553-6. PubMed ID: 19190025
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Biomechanical implications of the congenital bicuspid aortic valve: a finite element study of aortic root function from in vivo data.
    Conti CA; Della Corte A; Votta E; Del Viscovo L; Bancone C; De Santo LS; Redaelli A
    J Thorac Cardiovasc Surg; 2010 Oct; 140(4):890-6, 896.e1-2. PubMed ID: 20363481
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Design of a cyclic pressure bioreactor for the ex vivo study of aortic heart valves.
    Schipke KJ; To SD; Warnock JN
    J Vis Exp; 2011 Aug; (54):. PubMed ID: 21876532
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The effects of cellular contraction on aortic valve leaflet flexural stiffness.
    Merryman WD; Huang HY; Schoen FJ; Sacks MS
    J Biomech; 2006; 39(1):88-96. PubMed ID: 16271591
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The impact of imperfect frame deployment and rotational orientation on stress within the prosthetic leaflets during transcatheter aortic valve implantation.
    Bailey J; Curzen N; Bressloff NW
    J Biomech; 2017 Feb; 53():22-28. PubMed ID: 28118978
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The morphology of the normal aortic valve as compared with the aortic valve having two leaflets.
    Angelini A; Ho SY; Anderson RH; Devine WA; Zuberbuhler JR; Becker AE; Davies MJ
    J Thorac Cardiovasc Surg; 1989 Sep; 98(3):362-7. PubMed ID: 2770318
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Discussion of "Aortic valve mechanics Part II: A stress analysis of the porcine aortic valve leaflets in diastole" Biomat. Med. Dev. 6(3), 225-244 (1978).
    Gould PL; Rossow MP
    Biomater Med Devices Artif Organs; 1979; 7(3):435-42. PubMed ID: 476259
    [No Abstract]   [Full Text] [Related]  

  • 40. An in vivo study of the dimensional changes of the aortic valve leaflets during the cardiac cycle.
    Brewer RJ; Mentzer RM; Deck JD; Ritter RC; Trefil JS; Nolan SP
    J Thorac Cardiovasc Surg; 1977 Oct; 74(4):645-50. PubMed ID: 904366
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.