These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 3168218)

  • 1. Estradiol-17 beta quantified in serum by isotope dilution-gas chromatography-mass spectrometry: reversed-phase C18 high-performance liquid chromatography compared with immuno-affinity chromatography for sample pretreatment.
    Thienpont LM; Verhaeghe PG; Van Brussel KA; De Leenheer AP
    Clin Chem; 1988 Oct; 34(10):2066-9. PubMed ID: 3168218
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of oestradiol-17 beta in human serum by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, II.
    Siekmann L
    J Clin Chem Clin Biochem; 1984 Aug; 22(8):551-7. PubMed ID: 6387038
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and evaluation of a reference measurement procedure for the determination of estradiol-17beta in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry.
    Tai SS; Welch MJ
    Anal Chem; 2005 Oct; 77(19):6359-63. PubMed ID: 16194100
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous quantitation of endogenous estrone, 17β-estradiol, and estriol in human serum by isotope-dilution liquid chromatography-tandem mass spectrometry for clinical laboratory applications.
    Zhang Q; Han L; Wang J; Lin H; Ke P; Zhuang J; Huang X
    Anal Bioanal Chem; 2017 Apr; 409(10):2627-2638. PubMed ID: 28224243
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Isotope dilution-gas chromatography/mass spectrometry and liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of triiodo-L-thyronine in serum.
    Thienpont LM; Fierens C; De Leenheer AP; Przywara L
    Rapid Commun Mass Spectrom; 1999; 13(19):1924-31. PubMed ID: 10487939
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry.
    Tai SS; Xu B; Welch MJ
    Anal Chem; 2006 Sep; 78(18):6628-33. PubMed ID: 16970343
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method.
    Dai X; Fang X; Zhang C; Xu R; Xu B
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Oct; 857(2):287-95. PubMed ID: 17704012
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).
    Fernández-Fernández M; Rodríguez-González P; Añón Álvarez ME; Rodríguez F; Menéndez FV; García Alonso JI
    Anal Chem; 2015 Apr; 87(7):3755-63. PubMed ID: 25751287
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of an Isotope Dilution HPLC Tandem Mass Spectrometry Candidate Reference Measurement Procedure for Total 17-β Estradiol in Human Serum.
    Botelho JC; Ribera A; Cooper HC; Vesper HW
    Anal Chem; 2016 Nov; 88(22):11123-11129. PubMed ID: 27744701
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Quantification of urinary excretion of 1,N6-ethenoadenine, a potential biomarker of lipid peroxidation, in humans by stable isotope dilution liquid chromatography-electrospray ionization-tandem mass spectrometry: comparison with gas chromatography-mass spectrometry.
    Chen HJ; Chang CM
    Chem Res Toxicol; 2004 Jul; 17(7):963-71. PubMed ID: 15257622
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement by isotope dilution mass spectrometry of 17 alpha-ethynyloestradiol-17 beta and norethisterone in serum of women taking oral contraceptives.
    Siekmann L; Siekmann A; Breuer H
    Biomed Mass Spectrom; 1980 Nov; 7(11-12):511-4. PubMed ID: 7013845
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of estradiol, estrone, and testosterone in postmenopausal human serum by isotope dilution liquid chromatography tandem mass spectrometry without derivatization.
    Wooding KM; Hankin JA; Johnson CA; Chosich JD; Baek SW; Bradford AP; Murphy RC; Santoro N
    Steroids; 2015 Apr; 96():89-94. PubMed ID: 25617740
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.
    Tai SS; Welch MJ
    Anal Chem; 2004 Feb; 76(4):1008-14. PubMed ID: 14961732
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Serum estradiol quantified by isotope dilution-gas chromatography/mass spectrometry.
    Wu H; Ramsay C; Ozaeta P; Liu L; Aboleneen H
    Clin Chem; 2002 Feb; 48(2):364-6. PubMed ID: 11805022
    [No Abstract]   [Full Text] [Related]  

  • 15. S1 certification of alpha-endosulfan, beta-endosulfan, and endosulfan sulfate in a candidate certified reference material (organochlorine pesticides in tea) by isotope dilution gas chromatography-mass spectrometry.
    Sin DW; Wong YL; Cheng EC; Lo MF; Ho C; Mok CS; Wong SK
    Anal Bioanal Chem; 2015 Apr; 407(11):3009-21. PubMed ID: 25619984
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of gas chromatography and liquid chromatography mass spectrometric measurements for high accuracy analysis of cholesterol in human serum by isotope dilution mass spectrometry.
    Briche CS; Carter D; Webb KS
    Rapid Commun Mass Spectrom; 2002; 16(9):848-53. PubMed ID: 11948815
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Isotope dilution-liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of serum thyroxine as a potential reference method.
    De Brabandere VI; Hou P; Stöckl D; Thienpont LM; De Leenheer AP
    Rapid Commun Mass Spectrom; 1998; 12(16):1099-103. PubMed ID: 9737016
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of 25-hydroxyvitamin D3 in serum by high performance liquid chromatography and isotope dilution-mass spectrometry.
    Holmberg I; Kristiansen T; Sturén M
    Scand J Clin Lab Invest; 1984 Jun; 44(4):275-82. PubMed ID: 6379844
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of reference method values by isotope dilution-gas chromatography/mass spectrometry: a five years' experience of two European Reference Laboratories.
    Thienpont LM; Van Nieuwenhove B; Stöckl D; Reinauer H; De Leenheer AP
    Eur J Clin Chem Clin Biochem; 1996 Oct; 34(10):853-60. PubMed ID: 8933112
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of total cholesterol in serum by liquid chromatography-isotope dilution mass spectrometry.
    Kock R; Delvoux B; Greiling H
    Clin Chem; 1997 Oct; 43(10):1896-903. PubMed ID: 9342010
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.