171 related articles for article (PubMed ID: 31684057)
1. Quantitative, Multi-institutional Evaluation of MR Thermometry Accuracy for Deep-Pelvic MR-Hyperthermia Systems Operating in Multi-vendor MR-systems Using a New Anthropomorphic Phantom.
Curto S; Aklan B; Mulder T; Mils O; Schmidt M; Lamprecht U; Peller M; Wessalowski R; Lindner LH; Fietkau R; Zips D; Bellizzi GG; van Holthe N; Franckena M; Paulides MM; van Rhoon GC
Cancers (Basel); 2019 Nov; 11(11):. PubMed ID: 31684057
[TBL] [Abstract][Full Text] [Related]
2. A multi-institution study: comparison of the heating patterns of five different MR-guided deep hyperthermia systems using an anthropomorphic phantom.
Curto S; Mulder HT; Aklan B; Mils O; Schmidt M; Lamprecht U; Peller M; Wessalowski R; Lindner LH; Fietkau R; Zips D; van Holthe N; Franckena M; Paulides MM; van Rhoon GC
Int J Hyperthermia; 2020; 37(1):1103-1115. PubMed ID: 32981391
[TBL] [Abstract][Full Text] [Related]
3. POD-Kalman filtering for improving noninvasive 3D temperature monitoring in MR-guided hyperthermia.
VilasBoas-Ribeiro I; Nouwens SAN; Curto S; Jager B; Franckena M; van Rhoon GC; Heemels WPMH; Paulides MM
Med Phys; 2022 Aug; 49(8):4955-4970. PubMed ID: 35717578
[TBL] [Abstract][Full Text] [Related]
4. Validation of MR thermometry: method for temperature probe sensor registration accuracy in head and neck phantoms.
Tarasek MR; Pellicer R; Hofstetter LW; Numan WC; Bakker JF; Kotek G; Togni P; Verhaart RF; Fiveland EW; Houston GC; van Rhoon GC; Paulides MM; Yeo DT
Int J Hyperthermia; 2014 Mar; 30(2):142-9. PubMed ID: 24571177
[TBL] [Abstract][Full Text] [Related]
5. Multi-echo gradient echo pulse sequences: which is best for PRFS MR thermometry guided hyperthermia?
Feddersen TV; Poot DHJ; Paulides MM; Salim G; van Rhoon GC; Hernandez-Tamames JA
Int J Hyperthermia; 2023; 40(1):2184399. PubMed ID: 36907223
[TBL] [Abstract][Full Text] [Related]
6. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation.
Chu W; Staruch RM; Pichardo S; Tillander M; Köhler MO; Huang Y; Ylihautala M; McGuffin M; Czarnota G; Hynynen K
Int J Radiat Oncol Biol Phys; 2016 Jul; 95(4):1259-67. PubMed ID: 27209510
[TBL] [Abstract][Full Text] [Related]
7. Quantitative MR thermometry based on phase-drift correction PRF shift method at 0.35 T.
Chen Y; Ge M; Ali R; Jiang H; Huang X; Qiu B
Biomed Eng Online; 2018 Apr; 17(1):39. PubMed ID: 29631576
[TBL] [Abstract][Full Text] [Related]
8. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
[TBL] [Abstract][Full Text] [Related]
9. Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.
Kneepkens E; Heijman E; Keupp J; Weiss S; Nicolay K; Grüll H
Invest Radiol; 2017 Oct; 52(10):620-630. PubMed ID: 28598900
[TBL] [Abstract][Full Text] [Related]
10. Drift correction for accurate PRF-shift MR thermometry during mild hyperthermia treatments with MR-HIFU.
Bing C; Staruch RM; Tillander M; Köhler MO; Mougenot C; Ylihautala M; Laetsch TW; Chopra R
Int J Hyperthermia; 2016 Sep; 32(6):673-87. PubMed ID: 27210733
[TBL] [Abstract][Full Text] [Related]
11. Clinical Performance and Future Potential of Magnetic Resonance Thermometry in Hyperthermia.
Feddersen TV; Hernandez-Tamames JA; Franckena M; van Rhoon GC; Paulides MM
Cancers (Basel); 2020 Dec; 13(1):. PubMed ID: 33374176
[TBL] [Abstract][Full Text] [Related]
12. A printed Yagi-Uda antenna for application in magnetic resonance thermometry guided microwave hyperthermia applicators.
Paulides MM; Mestrom RM; Salim G; Adela BB; Numan WC; Drizdal T; Yeo DT; Smolders AB
Phys Med Biol; 2017 Mar; 62(5):1831-1847. PubMed ID: 28052042
[TBL] [Abstract][Full Text] [Related]
13. Exploration of MR-guided head and neck hyperthermia by phantom testing of a modified prototype applicator for use with proton resonance frequency shift thermometry.
Numan WC; Hofstetter LW; Kotek G; Bakker JF; Fiveland EW; Houston GC; Kudielka G; Yeo DT; Paulides MM
Int J Hyperthermia; 2014 May; 30(3):184-91. PubMed ID: 24773040
[TBL] [Abstract][Full Text] [Related]
14. A practical approach to thermography in a hyperthermia/magnetic resonance hybrid system: validation in a heterogeneous phantom.
Gellermann J; Wlodarczyk W; Ganter H; Nadobny J; Fähling H; Seebass M; Felix R; Wust P
Int J Radiat Oncol Biol Phys; 2005 Jan; 61(1):267-77. PubMed ID: 15629620
[TBL] [Abstract][Full Text] [Related]
15. Fiber Bragg Grating Sensors for Performance Evaluation of Fast Magnetic Resonance Thermometry on Synthetic Phantom.
De Landro M; Ianniello J; Yon M; Wolf A; Quesson B; Schena E; Saccomandi P
Sensors (Basel); 2020 Nov; 20(22):. PubMed ID: 33198326
[TBL] [Abstract][Full Text] [Related]
16. Laboratory prototype for experimental validation of MR-guided radiofrequency head and neck hyperthermia.
Paulides MM; Bakker JF; Hofstetter LW; Numan WC; Pellicer R; Fiveland EW; Tarasek M; Houston GC; van Rhoon GC; Yeo DT; Kotek G
Phys Med Biol; 2014 May; 59(9):2139-54. PubMed ID: 24699230
[TBL] [Abstract][Full Text] [Related]
17. MR thermometry-guided ultrasound hyperthermia of user-defined regions using the ExAblate prostate ablation array.
Ozhinsky E; Salgaonkar VA; Diederich CJ; Rieke V
J Ther Ultrasound; 2018; 6():7. PubMed ID: 30123506
[TBL] [Abstract][Full Text] [Related]
18. The Potential of Adjusting Water Bolus Liquid Properties for Economic and Precise MR Thermometry Guided Radiofrequency Hyperthermia.
Sumser K; Bellizzi GG; van Rhoon GC; Paulides MM
Sensors (Basel); 2020 May; 20(10):. PubMed ID: 32456027
[TBL] [Abstract][Full Text] [Related]
19. Breath-hold MR-HIFU hyperthermia: phantom and
Bing C; Cheng B; Staruch RM; Nofiele J; Wodzak Staruch M; Szczepanski D; Farrow-Gillespie A; Yang A; Laetsch TW; Chopra R
Int J Hyperthermia; 2019; 36(1):1084-1097. PubMed ID: 31707872
[No Abstract] [Full Text] [Related]
20. Systematic quality assurance of the BSD2000-3D MR-compatible hyperthermia applicator performance using MR temperature imaging.
Mulder HT; Curto S; Paulides MM; Franckena M; van Rhoon GC
Int J Hyperthermia; 2018; 35(1):305-313. PubMed ID: 30204006
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]