BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

263 related articles for article (PubMed ID: 31688980)

  • 1. Comparison of disinfection performance of UVC-LED and conventional upper-room UVGI systems.
    Nunayon SS; Zhang H; Lai ACK
    Indoor Air; 2020 Jan; 30(1):180-191. PubMed ID: 31688980
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel upper-room UVC-LED irradiation system for disinfection of indoor bioaerosols under different operating and airflow conditions.
    Nunayon SS; Zhang HH; Lai ACK
    J Hazard Mater; 2020 Sep; 396():122715. PubMed ID: 32361131
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minimizing the exposure of airborne pathogens by upper-room ultraviolet germicidal irradiation: an experimental and numerical study.
    Yang Y; Chan WY; Wu CL; Kong RY; Lai AC
    J R Soc Interface; 2012 Dec; 9(77):3184-95. PubMed ID: 22809847
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of ventilation strategy on performance of upper-room ultraviolet germicidal irradiation (UVGI) system in a learning environment.
    Park S; Mistrick R; Sitzabee W; Rim D
    Sci Total Environ; 2023 Nov; 899():165454. PubMed ID: 37467991
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Disinfection efficacy of ultraviolet germicidal irradiation on airborne bacteria in ventilation ducts.
    Yang Y; Zhang H; Nunayon SS; Chan V; Lai AC
    Indoor Air; 2018 Nov; 28(6):806-817. PubMed ID: 30171727
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Numerical investigation of upper-room UVGI disinfection efficacy in an environmental chamber with a ceiling fan.
    Zhu S; Srebric J; Rudnick SN; Vincent RL; Nardell EA
    Photochem Photobiol; 2013; 89(4):782-91. PubMed ID: 23311354
    [TBL] [Abstract][Full Text] [Related]  

  • 7. UVC LED Irradiation Effectively Inactivates Aerosolized Viruses, Bacteria, and Fungi in a Chamber-Type Air Disinfection System.
    Kim DK; Kang DH
    Appl Environ Microbiol; 2018 Sep; 84(17):. PubMed ID: 29959245
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fundamental factors affecting upper-room ultraviolet germicidal irradiation - part II. Predicting effectiveness.
    Rudnick SN; First MW
    J Occup Environ Hyg; 2007 May; 4(5):352-62. PubMed ID: 17454503
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Eggcrate UV: a whole ceiling upper-room ultraviolet germicidal irradiation system for air disinfection in occupied rooms.
    Linnes JC; Rudnick SN; Hunt GM; McDevitt JJ; Nardell EA
    Indoor Air; 2014 Apr; 24(2):116-24. PubMed ID: 23889191
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Using computational fluid dynamics modeling to evaluate the design of hospital ultraviolet germicidal irradiation systems for inactivating airborne mycobacteria.
    Xu P; Fisher N; Miller SL
    Photochem Photobiol; 2013; 89(4):792-8. PubMed ID: 23418820
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Upper-room ultraviolet germicidal irradiation (UVGI) for air disinfection: a symposium in print.
    Nardell E; Vincent R; Sliney DH
    Photochem Photobiol; 2013; 89(4):764-9. PubMed ID: 23683092
    [TBL] [Abstract][Full Text] [Related]  

  • 12. UV air cleaners and upper-room air ultraviolet germicidal irradiation for controlling airborne bacteria and fungal spores.
    Kujundzic E; Matalkah F; Howard CJ; Hernandez M; Miller SL
    J Occup Environ Hyg; 2006 Oct; 3(10):536-46. PubMed ID: 16908454
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of ultraviolet germicidal irradiation and swirling motion on airborne Staphylococcus aureus, Pseudomonas aeruginosa and Legionella pneumophila under various relative humidities.
    Chang CW; Li SY; Huang SH; Huang CK; Chen YY; Chen CC
    Indoor Air; 2013 Feb; 23(1):74-84. PubMed ID: 22680348
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A pilot study on the disinfection efficacy of localized UV on the flushing-generated spread of pathogens.
    Lai ACK; Nunayon SS; Tan TF; Li WS
    J Hazard Mater; 2018 Sep; 358():389-396. PubMed ID: 30005250
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Estimating the germicidal effect of upper-room UVGI system on exhaled air of patients based on ventilation efficiency.
    Sung M; Kato S
    Build Environ; 2011 Nov; 46(11):2326-2332. PubMed ID: 32288012
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of hospital room surface disinfection using a novel ultraviolet germicidal irradiation (UVGI) generator.
    Jelden KC; Gibbs SG; Smith PW; Hewlett AL; Iwen PC; Schmid KK; Lowe JJ
    J Occup Environ Hyg; 2016 Sep; 13(9):690-8. PubMed ID: 27028152
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ultraviolet germicidal irradiation: future directions for air disinfection and building applications.
    Miller SL; Linnes J; Luongo J
    Photochem Photobiol; 2013; 89(4):777-81. PubMed ID: 23581680
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ambulance disinfection using Ultraviolet Germicidal Irradiation (UVGI): Effects of fixture location and surface reflectivity.
    Lindsley WG; McClelland TL; Neu DT; Martin SB; Mead KR; Thewlis RE; Noti JD
    J Occup Environ Hyg; 2018 Jan; 15(1):1-12. PubMed ID: 29059039
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluating the efficacy of a rotating upper-room UVC-LED irradiation device in inactivating aerosolized Escherichia coli under different disinfection ranges, air mixing, and irradiation conditions.
    Nunayon SS; Wang M; Zhang HH; Lai ACK
    J Hazard Mater; 2022 Oct; 440():129791. PubMed ID: 36027747
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bioaerosol size as a potential determinant of airborne
    Hao W; Huang YW; Wang Y
    Nanotechnology; 2024 Jan; 35(14):. PubMed ID: 38086064
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.