These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

277 related articles for article (PubMed ID: 31689757)

  • 1. Mechanical chest compression with LUCAS device does not improve clinical outcome in out-of-hospital cardiac arrest patients: A systematic review and meta-analysis.
    Liu M; Shuai Z; Ai J; Tang K; Liu H; Zheng J; Gou J; Lv Z
    Medicine (Baltimore); 2019 Nov; 98(44):e17550. PubMed ID: 31689757
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prehospital randomised assessment of a mechanical compression device in out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised trial and economic evaluation.
    Gates S; Lall R; Quinn T; Deakin CD; Cooke MW; Horton J; Lamb SE; Slowther AM; Woollard M; Carson A; Smyth M; Wilson K; Parcell G; Rosser A; Whitfield R; Williams A; Jones R; Pocock H; Brock N; Black JJ; Wright J; Han K; Shaw G; Blair L; Marti J; Hulme C; McCabe C; Nikolova S; Ferreira Z; Perkins GD
    Health Technol Assess; 2017 Mar; 21(11):1-176. PubMed ID: 28393757
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Continuous chest compression versus interrupted chest compression for cardiopulmonary resuscitation of non-asphyxial out-of-hospital cardiac arrest.
    Zhan L; Yang LJ; Huang Y; He Q; Liu GJ
    Cochrane Database Syst Rev; 2017 Mar; 3(3):CD010134. PubMed ID: 28349529
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A meta-analysis of the resuscitative effects of mechanical and manual chest compression in out-of-hospital cardiac arrest patients.
    Zhu N; Chen Q; Jiang Z; Liao F; Kou B; Tang H; Zhou M
    Crit Care; 2019 Mar; 23(1):100. PubMed ID: 30917840
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical versus manual chest compressions for cardiac arrest: a systematic review and meta-analysis.
    Li H; Wang D; Yu Y; Zhao X; Jing X
    Scand J Trauma Resusc Emerg Med; 2016 Feb; 24():10. PubMed ID: 26830837
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Manual Cardiopulmonary Resuscitation Versus CPR Including a Mechanical Chest Compression Device in Out-of-Hospital Cardiac Arrest: A Comprehensive Meta-analysis From Randomized and Observational Studies.
    Bonnes JL; Brouwer MA; Navarese EP; Verhaert DV; Verheugt FW; Smeets JL; de Boer MJ
    Ann Emerg Med; 2016 Mar; 67(3):349-360.e3. PubMed ID: 26607332
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial.
    Perkins GD; Lall R; Quinn T; Deakin CD; Cooke MW; Horton J; Lamb SE; Slowther AM; Woollard M; Carson A; Smyth M; Whitfield R; Williams A; Pocock H; Black JJ; Wright J; Han K; Gates S;
    Lancet; 2015 Mar; 385(9972):947-55. PubMed ID: 25467566
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical versus manual chest compressions for cardiac arrest.
    Wang PL; Brooks SC
    Cochrane Database Syst Rev; 2018 Aug; 8(8):CD007260. PubMed ID: 30125048
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quality of cardiopulmonary resuscitation in out-of-hospital cardiac arrest before and after introduction of a mechanical chest compression device, LUCAS-2; a prospective, observational study.
    Tranberg T; Lassen JF; Kaltoft AK; Hansen TM; Stengaard C; Knudsen L; Trautner S; Terkelsen CJ
    Scand J Trauma Resusc Emerg Med; 2015 Apr; 23():37. PubMed ID: 25898992
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prompt use of mechanical cardiopulmonary resuscitation in out-of-hospital cardiac arrest: the MECCA study report.
    Anantharaman V; Ng BL; Ang SH; Lee CY; Leong SH; Ong ME; Chua SJ; Rabind AC; Anjali NB; Hao Y
    Singapore Med J; 2017 Jul; 58(7):424-431. PubMed ID: 28741013
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical chest compressions and simultaneous defibrillation vs conventional cardiopulmonary resuscitation in out-of-hospital cardiac arrest: the LINC randomized trial.
    Rubertsson S; Lindgren E; Smekal D; Östlund O; Silfverstolpe J; Lichtveld RA; Boomars R; Ahlstedt B; Skoog G; Kastberg R; Halliwell D; Box M; Herlitz J; Karlsten R
    JAMA; 2014 Jan; 311(1):53-61. PubMed ID: 24240611
    [TBL] [Abstract][Full Text] [Related]  

  • 12. No Benefit in Neurologic Outcomes of Survivors of Out-of-Hospital Cardiac Arrest with Mechanical Compression Device.
    Newberry R; Redman T; Ross E; Ely R; Saidler C; Arana A; Wampler D; Miramontes D
    Prehosp Emerg Care; 2018; 22(3):338-344. PubMed ID: 29345513
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Outcome among VF/VT patients in the LINC (LUCAS IN cardiac arrest) trial-A randomised, controlled trial.
    Hardig BM; Lindgren E; Östlund O; Herlitz J; Karlsten R; Rubertsson S
    Resuscitation; 2017 Jun; 115():155-162. PubMed ID: 28385642
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical chest compression for out of hospital cardiac arrest: Systematic review and meta-analysis.
    Gates S; Quinn T; Deakin CD; Blair L; Couper K; Perkins GD
    Resuscitation; 2015 Sep; 94():91-7. PubMed ID: 26190673
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation.
    Ong ME; Ornato JP; Edwards DP; Dhindsa HS; Best AM; Ines CS; Hickey S; Clark B; Williams DC; Powell RG; Overton JL; Peberdy MA
    JAMA; 2006 Jun; 295(22):2629-37. PubMed ID: 16772626
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Chest compressions before defibrillation for out-of-hospital cardiac arrest: a meta-analysis of randomized controlled clinical trials.
    Meier P; Baker P; Jost D; Jacobs I; Henzi B; Knapp G; Sasson C
    BMC Med; 2010 Sep; 8():52. PubMed ID: 20828395
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mechanical CPR devices compared to manual CPR during out-of-hospital cardiac arrest and ambulance transport: a systematic review.
    Ong ME; Mackey KE; Zhang ZC; Tanaka H; Ma MH; Swor R; Shin SD
    Scand J Trauma Resusc Emerg Med; 2012 Jun; 20():39. PubMed ID: 22709917
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Active chest compression-decompression for cardiopulmonary resuscitation.
    Lafuente-Lafuente C; Melero-Bascones M
    Cochrane Database Syst Rev; 2013 Sep; 2013(9):CD002751. PubMed ID: 24052483
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Meta-analysis of chest compression-only versus conventional cardiopulmonary resuscitation by bystanders for adult with out-of-hospital cardiac arrest.
    Bielski K; Smereka J; Chmielewski J; Pruc M; Chirico F; Gasecka A; Litvinova N; Jaguszewski MJ; Nowak-Starz G; Rafique Z; Peacock FW; Szarpak L
    Cardiol J; 2023; 30(4):606-613. PubMed ID: 34622436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Safety of mechanical chest compression devices AutoPulse and LUCAS in cardiac arrest: a randomized clinical trial for non-inferiority.
    Koster RW; Beenen LF; van der Boom EB; Spijkerboer AM; Tepaske R; van der Wal AC; Beesems SG; Tijssen JG
    Eur Heart J; 2017 Oct; 38(40):3006-3013. PubMed ID: 29088439
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.