BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

231 related articles for article (PubMed ID: 31693093)

  • 1. Impact of monitoring on detection of arrhythmia recurrences in the ESC-EHRA EORP atrial fibrillation ablation long-term registry.
    Balabanski T; Brugada J; Arbelo E; Laroche C; Maggioni A; Blomström-Lundqvist C; Kautzner J; Tavazzi L; Tritto M; Kulakowski P; Kalejs O; Forster T; Villalobos FS; Dagres N;
    Europace; 2019 Dec; 21(12):1802-1808. PubMed ID: 31693093
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of transtelephonic electrocardiographic monitoring in detecting short-term arrhythmia recurrences after radiofrequency ablation in patients with atrial fibrillation.
    Senatore G; Stabile G; Bertaglia E; Donnici G; De Simone A; Zoppo F; Turco P; Pascotto P; Fazzari M
    J Am Coll Cardiol; 2005 Mar; 45(6):873-6. PubMed ID: 15766823
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Daily ECG transmission versus serial 6-day Holter ECG for the assessment of efficacy of ablation for atrial fibrillation - the AGNES-ECG study.
    Sikorska A; Baran J; Piotrowski R; Kryński T; Szymot J; Soszyńska M; Kułakowski P
    J Interv Card Electrophysiol; 2022 Nov; 65(2):373-380. PubMed ID: 35244820
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Which patients with atrial fibrillation undergo an ablation procedure today in Europe? A report from the ESC-EHRA-EORP Atrial Fibrillation Ablation Long-Term and Atrial Fibrillation General Pilot Registries.
    Tilz RR; Dagres N; Arbelo E; Blomström-Lundqvist C; Crijns HJ; Kirchhof P; Kautzner J; Temporelli PL; Laroche C; Roberts PR; Pehrson S; Lip GYH; Brugada J; Tavazzi L;
    Europace; 2020 Feb; 22(2):250-258. PubMed ID: 31768523
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Symptomatic and asymptomatic long-term recurrences following transcatheter atrial fibrillation ablation.
    Manganiello S; Anselmino M; Amellone C; Pelissero E; Giuggia M; Trapani G; Giordano B; Senatore G; Gaita F
    Pacing Clin Electrophysiol; 2014 Jun; 37(6):697-702. PubMed ID: 24665920
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dry textile electrode for ambulatory monitoring after catheter ablation of atrial fibrillation: A pilot study of simultaneous comparison to the Holter electrocardiogram.
    Machino T; Aonuma K; Komatsu Y; Yamasaki H; Igarashi M; Nogami A; Ieda M
    F1000Res; 2022; 11():97. PubMed ID: 35860478
    [No Abstract]   [Full Text] [Related]  

  • 7. Long-term intermittent versus short continuous heart rhythm monitoring for the detection of atrial fibrillation recurrences after catheter ablation.
    Hermans ANL; Gawalko M; Pluymaekers NAHA; Dinh T; Weijs B; van Mourik MJW; Vorstermans B; den Uijl DW; Opsteyn L; Snippe H; Vernooy K; Crijns HJGM; Linz D; Luermans JGLM
    Int J Cardiol; 2021 Apr; 329():105-112. PubMed ID: 33412184
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of atrial fibrillation ablation outcomes with clinic ECG, monthly 24-h Holter ECG, and twice-daily telemonitoring ECG.
    Kimura T; Aizawa Y; Kurata N; Nakajima K; Kashimura S; Kunitomi A; Nishiyama T; Katsumata Y; Nishiyama N; Fukumoto K; Tanimoto Y; Fukuda K; Takatsuki S
    Heart Vessels; 2017 Mar; 32(3):317-325. PubMed ID: 27385021
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Value of different follow-up strategies to assess the efficacy of circumferential pulmonary vein ablation for the curative treatment of atrial fibrillation.
    Piorkowski C; Kottkamp H; Tanner H; Kobza R; Nielsen JC; Arya A; Hindricks G
    J Cardiovasc Electrophysiol; 2005 Dec; 16(12):1286-92. PubMed ID: 16403058
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of two modes of long-term ECG monitoring to assess the efficacy of catheter ablation for paroxysmal atrial fibrillation.
    Chovancik J; Bulkova V; Wichterle D; Toman O; Rybka L; Januska J; Spinar J; Fiala M
    Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub; 2019 Feb; 163(1):54-60. PubMed ID: 29955186
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of centre volume on atrial fibrillation ablation outcomes in Europe: a report from the ESC EHRA EORP Atrial Fibrillation Ablation Long-Term (AFA LT) Registry.
    Vassilikos VP; Pagourelias ED; Laroche C; Blomström-Lundqvist C; Kautzner J; Maggioni AP; Tavazzi L; Dagres N; Brugada J; Stühlinger M; Arbelo E;
    Europace; 2021 Jan; 23(1):49-58. PubMed ID: 33141150
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnostic utility of long-term remote ECG monitoring in compare with 24 hour Holter monitoring in patients with atrial fibrillation after catheter radiofrequency ablation in the early postoperative period.
    Ryabykina GV; Shokhzodaeva ZO; Sapelnikov OV; Makeev MI; Kozhemyakina ES; Shchedrina EV; Volkov VE; Akchurin RS
    Ter Arkh; 2018 Dec; 90(12):12-16. PubMed ID: 30701827
    [TBL] [Abstract][Full Text] [Related]  

  • 13. :Influence of the duration of Holter monitoring on the detection of arrhythmia recurrences after catheter ablation of atrial fibrillation: implications for patient follow-up.
    Dagres N; Kottkamp H; Piorkowski C; Weis S; Arya A; Sommer P; Bode K; Gerds-Li JH; Kremastinos DT; Hindricks G
    Int J Cardiol; 2010 Mar; 139(3):305-6. PubMed ID: 18990460
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early Detection of Symptomatic Paroxysmal Cardiac Arrhythmias by Trans-Telephonic ECG Monitoring: Impact on Diagnosis and Treatment of Atrial Fibrillation.
    Anczykowski J; Willems S; Hoffmann BA; Meinertz T; Blankenberg S; Patten M
    J Cardiovasc Electrophysiol; 2016 Sep; 27(9):1032-7. PubMed ID: 27257094
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Five-year follow-up after catheter ablation of persistent atrial fibrillation using the stepwise approach and prognostic factors for success.
    Schreiber D; Rostock T; Fröhlich M; Sultan A; Servatius H; Hoffmann BA; Lüker J; Berner I; Schäffer B; Wegscheider K; Lezius S; Willems S; Steven D
    Circ Arrhythm Electrophysiol; 2015 Apr; 8(2):308-17. PubMed ID: 25744570
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous monitoring after atrial fibrillation ablation: the LINQ AF study.
    Wechselberger S; Kronborg M; Huo Y; Piorkowski J; Neudeck S; Päßler E; El-Armouche A; Richter U; Mayer J; Ulbrich S; Pu L; Kirstein B; Gaspar T; Piorkowski C
    Europace; 2018 Nov; 20(FI_3):f312-f320. PubMed ID: 29688326
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Assessment of atrial fibrillation ablation outcome: from symptoms to continuous monitoring with an implantable loop recorder].
    Rordorf R; Vicentini A; Landolina M
    G Ital Cardiol (Rome); 2008 Oct; 9(10 Suppl 1):16S-21S. PubMed ID: 19195301
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Randomized crossover trial of 2-week Garment electrocardiogram with dry textile electrode to reveal instances of post-ablation recurrence of atrial fibrillation underdiagnosed during 24-hour Holter monitoring.
    Machino T; Aonuma K; Maruo K; Komatsu Y; Yamasaki H; Igarashi M; Nogami A; Ieda M
    PLoS One; 2023; 18(2):e0281818. PubMed ID: 36827294
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Predictors of Long-term Success After Concomitant Surgical Ablation for Atrial Fibrillation.
    Pecha S; Ghandili S; Hakmi S; Willems S; Reichenspurner H; Wagner FM
    Semin Thorac Cardiovasc Surg; 2017 Autumn; 29(3):294-298. PubMed ID: 28964598
    [TBL] [Abstract][Full Text] [Related]  

  • 20. AFA-Recur: an ESC EORP AFA-LT registry machine-learning web calculator predicting atrial fibrillation recurrence after ablation.
    Saglietto A; Gaita F; Blomstrom-Lundqvist C; Arbelo E; Dagres N; Brugada J; Maggioni AP; Tavazzi L; Kautzner J; De Ferrari GM; Anselmino M
    Europace; 2023 Feb; 25(1):92-100. PubMed ID: 36006664
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.