These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 31697345)

  • 1. Falsely elevated vancomycin-concentration values from enzyme immunoassay leading to treatment failure.
    Singer B; Stevens RW; Westley BP; Nicolau DP
    Am J Health Syst Pharm; 2020 Jan; 77(1):9-13. PubMed ID: 31697345
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Falsely Elevated Vancomycin Concentrations in a Patient Not Receiving Vancomycin.
    Tsoi V; Bhayana V; Bombassaro AM; Tirona RG; Kittanakom S
    Pharmacotherapy; 2019 Jul; 39(7):778-782. PubMed ID: 31077424
    [TBL] [Abstract][Full Text] [Related]  

  • 3. New modified fluorescence polarization immunoassay does not falsely elevate vancomycin concentrations in patients with end-stage renal disease.
    Smith PF; Petros WP; Soucie MP; Copeland KR
    Ther Drug Monit; 1998 Apr; 20(2):231-5. PubMed ID: 9558140
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of high-performance liquid chromatography with fluorescence polarization immunoassay for the analysis of vancomycin in patients with chronic renal failure.
    Najjar TA; al-Dhuwailie AA; Tekle A
    J Chromatogr B Biomed Appl; 1995 Oct; 672(2):295-9. PubMed ID: 8581137
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Two suspected cases of immunoglobulin-mediated interference causing falsely low vancomycin concentrations with the Beckman PETINIA method.
    Gunther M; Saxinger L; Gray M; Legatt D
    Ann Pharmacother; 2013 Apr; 47(4):e19. PubMed ID: 23512662
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Undetectable Vancomycin Concentrations Utilizing a Particle Enhanced Turbidimetric Inhibition Immunoassay in a Patient with an Elevated IgM Level.
    Cooper AA; Cowart K; Clayton A; Paul J
    Clin Lab; 2017 Sep; 63(9):1527-1532. PubMed ID: 28879698
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Underestimation of rat serum vancomycin concentrations measured by an enzyme-multiplied immunoassay technique and the strategy for its avoidance.
    Konishi H; Iga I; Nagai K
    Drug Test Anal; 2014 Apr; 6(4):350-6. PubMed ID: 23943307
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Vancomycin monitoring in term newborns: comparison of peak and trough serum concentrations determined by high performance liquid chromatography and fluorescence polarization immunoassay.
    Feferbaum R; Kobol Machado JK; de Albuquerque Diniz EM; Okay TS; Santos SR; Ceccon ME; Krebs VL; de Araújo MC; Costa Vaz A
    Rev Hosp Clin Fac Med Sao Paulo; 2001; 56(5):149-52. PubMed ID: 11781595
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Falsely elevated serum vancomycin concentrations in hemodialysis patients.
    Follin SL; Mueller BA; Scott MK; Carfagna MA; Kraus MA
    Am J Kidney Dis; 1996 Jan; 27(1):67-74. PubMed ID: 8546140
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Clinical laboratory-based assay methodologies may underestimate and increase variability of vancomycin protein binding in hospitalized patients.
    Crandon JL; MacVane SH; Nicolau DP
    Pharmacotherapy; 2014 Feb; 34(2):203-9. PubMed ID: 23798336
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development and validation of a new ultra-performance liquid chromatographic method for vancomycin assay in serum and its application to therapeutic drug monitoring.
    Cao Y; Yu J; Chen Y; Zhang J; Wu X; Zhang Y; Li G
    Ther Drug Monit; 2014 Apr; 36(2):175-81. PubMed ID: 24216537
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Abbott AxSYM Vancomycin II assay: multicenter evaluation and interference studies.
    Azzazy HM; Chou PP; Tsushima JH; Troxil S; Gordon M; Avers RJ; Chiappetta E; Duh SH; Christenson RH
    Ther Drug Monit; 1998 Apr; 20(2):202-8. PubMed ID: 9558135
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a quantitative vancomycin immunoassay for the Abbott AxSYM analyzer.
    Adamczyk M; Brate EM; Chiappetta EG; Ginsburg S; Hoffman E; Klein C; Perkowitz MM; Rege SD; Chou PP; Costantino AG
    Ther Drug Monit; 1998 Apr; 20(2):191-201. PubMed ID: 9558134
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An improved micromethod for vancomycin determination by high-performance liquid chromatography.
    Li L; Miles MV; Hall W; Carson SW
    Ther Drug Monit; 1995 Aug; 17(4):366-70. PubMed ID: 7482691
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Implications of vancomycin degradation products on therapeutic drug monitoring in patients with end-stage renal disease.
    Somerville AL; Wright DH; Rotschafer JC
    Pharmacotherapy; 1999 Jun; 19(6):702-7. PubMed ID: 10391415
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Conversion from Vancomycin Trough Concentration-Guided Dosing to Area Under the Curve-Guided Dosing Using Two Sample Measurements in Adults: Implementation at an Academic Medical Center.
    Meng L; Wong T; Huang S; Mui E; Nguyen V; Espinosa G; Desai J; Holubar M; Deresinski S
    Pharmacotherapy; 2019 Apr; 39(4):433-442. PubMed ID: 30739349
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Establishment of norvancomycin fluorescence polarization immunoassay for therapeutic drug monitoring.
    Wu XJ; Zhang J; Yu JC; Cao GY; Shi YG; Zhang YY; Wang MG
    J Antibiot (Tokyo); 2012 Jan; 65(1):35-9. PubMed ID: 22045420
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Instability of standard calibrators may be involved in overestimating vancomycin concentrations determined by fluorescence polarization immunoassay.
    Morishige H; Shuto H; Ieiri I; Otsubo K; Oishi R
    Ther Drug Monit; 1996 Feb; 18(1):80-5. PubMed ID: 8848826
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rapid serum vancomycin assay by high-performance liquid chromatography using a semipermeable surface packing material column.
    Furuta I; Kitahashi T; Kuroda T; Nishio H; Oka C; Morishima Y
    Clin Chim Acta; 2000 Nov; 301(1-2):31-9. PubMed ID: 11020460
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of vancomycin in renally impaired patient samples using a new high-performance liquid chromatography method with vitamin B12 internal standard: comparison of high-performance liquid chromatography, emit, and fluorescence polarization immunoassay methods.
    Hu MW; Anne L; Forni T; Gottwald K
    Ther Drug Monit; 1990 Nov; 12(6):562-9. PubMed ID: 2275003
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.