These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

209 related articles for article (PubMed ID: 31702646)

  • 21. Which Fingers Should We Perform Two-Finger Chest Compression Technique with When Performing Cardiopulmonary Resuscitation on an Infant in Cardiac Arrest?
    Kim YS; Oh JH; Kim CW; Kim SE; Lee DH; Hong JY
    J Korean Med Sci; 2016 Jun; 31(6):997-1002. PubMed ID: 27247512
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques.
    Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Conrad CJ; Kitscha DJ; Provo TA; Lurie KG
    Resuscitation; 2005 Mar; 64(3):353-62. PubMed ID: 15733766
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Chest compression quality and rescuer fatigue with increased compression to ventilation ratio during single rescuer pediatric CPR.
    Haque IU; Udassi JP; Udassi S; Theriaque DW; Shuster JJ; Zaritsky AL
    Resuscitation; 2008 Oct; 79(1):82-9. PubMed ID: 18617314
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Two new chest compression methods might challenge the standard in a simulated infant model.
    Rodriguez-Ruiz E; Martínez-Puga A; Carballo-Fazanes A; Abelairas-Gómez C; Rodríguez-Nuñez A
    Eur J Pediatr; 2019 Oct; 178(10):1529-1535. PubMed ID: 31446464
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A Randomized Control Trial of Cardiopulmonary Feedback Devices and Their Impact on Infant Chest Compression Quality: A Simulation Study.
    Austin AL; Spalding CN; Landa KN; Myer BR; Cure D; Smith JE; Platt G; King HC
    Pediatr Emerg Care; 2020 Feb; 36(2):e79-e84. PubMed ID: 29084067
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Rescuer-limited cardiopulmonary resuscitation as an alternative to 2-min switched CPR in the setting of inhospital cardiac arrest: a randomised cross-over study.
    Jo CH; Cho GC; Ahn JH; Park YS; Lee CH
    Emerg Med J; 2015 Jul; 32(7):539-43. PubMed ID: 25092797
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of alternative chest compression techniques in infant and child on rescuer performance.
    Udassi JP; Udassi S; Theriaque DW; Shuster JJ; Zaritsky AL; Haque IU
    Pediatr Crit Care Med; 2009 May; 10(3):328-33. PubMed ID: 19307812
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A Novel Infant Chest Compression Assist Device Using a Palm Rather Than Fingers: A Randomized Crossover Trial.
    Park JW; Jung JY; Kim J; Kwak YH; Kim DK; Lee JC; Ham EM; Hwang S; Kwon H
    Prehosp Emerg Care; 2019; 23(1):74-82. PubMed ID: 30118625
    [No Abstract]   [Full Text] [Related]  

  • 29. A vertical two-thumb technique is superior to the two-thumb encircling technique for infant cardiopulmonary resuscitation.
    Na JU; Choi PC; Lee HJ; Shin DH; Han SK; Cho JH
    Acta Paediatr; 2015 Feb; 104(2):e70-5. PubMed ID: 25382371
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Does a more "physiological" infant manikin design effect chest compression quality and create a potential for thoracic over-compression during simulated infant CPR?
    Martin PS; Kemp AM; Theobald PS; Maguire SA; Jones MD
    Resuscitation; 2013 May; 84(5):666-71. PubMed ID: 23123431
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effectiveness of finger-marker for maintaining the correct compression point during paediatric resuscitation: A simulation study.
    Jung JY; Kwak YH; Kwon H; Choi YJ; Kim DK; Kim HC; Lee JC; Park JH; Lim H
    Am J Emerg Med; 2017 Sep; 35(9):1303-1308. PubMed ID: 28483276
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparison between the two methods of chest compression in infant and neonatal resuscitation. A review according to 2010 CPR guidelines.
    Douvanas A; Koulouglioti C; Kalafati M
    J Matern Fetal Neonatal Med; 2018 Mar; 31(6):805-816. PubMed ID: 28282762
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A different rescuer changing strategy between 30:2 cardiopulmonary resuscitation and hands-only cardiopulmonary resuscitation that considers rescuer factors: a randomised cross-over simulation study with a time-dependent analysis.
    Hong DY; Park SO; Lee KR; Baek KJ; Shin DH
    Resuscitation; 2012 Mar; 83(3):353-9. PubMed ID: 22101200
    [TBL] [Abstract][Full Text] [Related]  

  • 34. New method of chest compression for infants in a single rescuer situation: thumb-index finger technique.
    Fakhraddin BZ; Shimizu N; Kurosawa S; Sakai H; Miyasaka K; Mizutani S
    J Med Dent Sci; 2011 Mar; 58(1):15-22. PubMed ID: 23896782
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Real-time feedback can improve infant manikin cardiopulmonary resuscitation by up to 79%--a randomised controlled trial.
    Martin P; Theobald P; Kemp A; Maguire S; Maconochie I; Jones M
    Resuscitation; 2013 Aug; 84(8):1125-30. PubMed ID: 23571117
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A novel CPR-assist device vs. established chest compression techniques in infant CPR: A manikin study.
    Kao CL; Tsou JY; Hong MY; Chang CJ; Tu YF; Huang SP; Su FC; Chi CH
    Am J Emerg Med; 2024 Mar; 77():81-86. PubMed ID: 38118386
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Which position should we take during newborn resuscitation? A prospective, randomised, multicentre simulation trial.
    Smereka J; Kaminska H; Wieczorek W; Dąbrowski M; Ładny JR; Ruetzler K; Szarpak Ł; Robak O; Frass M
    Kardiol Pol; 2018; 76(6):980-986. PubMed ID: 29350383
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Do chest compressions during simulated infant CPR comply with international recommendations?
    Martin PS; Kemp AM; Theobald PS; Maguire SA; Jones MD
    Arch Dis Child; 2013 Aug; 98(8):576-81. PubMed ID: 23193200
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Chest compression quality comparing 1-min vs 2-min rotation of rescuers wearing N95 masks.
    Mathew MJ; Kundra P; Vinayagam S
    Am J Emerg Med; 2024 Feb; 76():75-81. PubMed ID: 38006635
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Individualized rescuer change by a team leader during uninterrupted cardiopulmonary resuscitation: comparison with rescuer change in 2-min intervals.
    Shin DH; Cho JH; Park SO
    Eur J Emerg Med; 2016 Aug; 23(4):263-268. PubMed ID: 25738793
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.