These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
302 related articles for article (PubMed ID: 31707723)
1. Outcomes during and after the use of the wearable cardioverter-defibrillator in a tertiary-care and a regional hospital in Switzerland. Kovacs B; Reek S; Saguner AM; Krasniqi N; Eriksson U; Duru F Swiss Med Wkly; 2019 Nov; 149():w20136. PubMed ID: 31707723 [TBL] [Abstract][Full Text] [Related]
2. Therapy optimization in patients with heart failure: the role of the wearable cardioverter-defibrillator in a real-world setting. Röger S; Rosenkaimer SL; Hohneck A; Lang S; El-Battrawy I; Rudic B; Tülümen E; Stach K; Kuschyk J; Akin I; Borggrefe M BMC Cardiovasc Disord; 2018 Mar; 18(1):52. PubMed ID: 29544442 [TBL] [Abstract][Full Text] [Related]
4. Experience with the wearable cardioverter-defibrillator in older patients: Results from the Prospective Registry of Patients Using the Wearable Cardioverter-Defibrillator. Daimee UA; Vermilye K; Moss AJ; Goldenberg I; Klein HU; McNitt S; Zareba W; Kutyifa V Heart Rhythm; 2018 Sep; 15(9):1379-1386. PubMed ID: 29678779 [TBL] [Abstract][Full Text] [Related]
5. Use of the wearable cardioverter defibrillator in high-risk cardiac patients: data from the Prospective Registry of Patients Using the Wearable Cardioverter Defibrillator (WEARIT-II Registry). Kutyifa V; Moss AJ; Klein H; Biton Y; McNitt S; MacKecknie B; Zareba W; Goldenberg I Circulation; 2015 Oct; 132(17):1613-9. PubMed ID: 26316618 [TBL] [Abstract][Full Text] [Related]
6. The wearable cardioverter-defibrillator in a real-world clinical setting: experience in 102 consecutive patients. Erath JW; Vamos M; Sirat AS; Hohnloser SH Clin Res Cardiol; 2017 Apr; 106(4):300-306. PubMed ID: 27888304 [TBL] [Abstract][Full Text] [Related]
7. Extended use of the wearable cardioverter-defibrillator in patients at risk for sudden cardiac death. Kutyifa V; Vermilye K; Daimee UA; McNitt S; Klein H; Moss AJ Europace; 2018 Sep; 20(FI2):f225-f232. PubMed ID: 29905788 [TBL] [Abstract][Full Text] [Related]
8. The US Experience of the Wearable Cardioverter-Defibrillator in Pediatric Patients. Spar DS; Bianco NR; Knilans TK; Czosek RJ; Anderson JB Circ Arrhythm Electrophysiol; 2018 Jul; 11(7):e006163. PubMed ID: 29945928 [TBL] [Abstract][Full Text] [Related]
9. Sex differences in arrhythmic burden with the wearable cardioverter-defibrillator. Goldenberg I; Erath JW; Russo AM; Burch AE; Assmus B; Bonderman D; McNitt S; Kutyifa V Heart Rhythm; 2021 Mar; 18(3):404-410. PubMed ID: 33248269 [TBL] [Abstract][Full Text] [Related]
10. Age differences of patients treated with wearable cardioverter defibrillator: Data from a multicentre registry. El-Battrawy I; Tenbrink D; Kovacs B; Dreher TC; Blockhaus C; Klein N; Shin DI; Hijazi M; Rosenkaimer S; Beiert T; Abumayyaleh M; Saguner AM; Kowitz J; Erath JW; Duru F; Mügge A; Aweimer A; Akin I Eur J Clin Invest; 2023 Jul; 53(7):e13977. PubMed ID: 36852491 [TBL] [Abstract][Full Text] [Related]
11. Avoiding Untimely Implantable Cardioverter/Defibrillator Implantation by Intensified Heart Failure Therapy Optimization Supported by the Wearable Cardioverter/Defibrillator-The PROLONG Study. Duncker D; König T; Hohmann S; Bauersachs J; Veltmann C J Am Heart Assoc; 2017 Jan; 6(1):. PubMed ID: 28096098 [TBL] [Abstract][Full Text] [Related]
12. Long-term use of the wearable cardioverter defibrillator in patients with explanted ICD. Kaspar G; Sanam K; Gholkar G; Bianco NR; Szymkiewicz S; Shah D Int J Cardiol; 2018 Dec; 272():179-184. PubMed ID: 30121177 [TBL] [Abstract][Full Text] [Related]
13. Wearable cardioverter defibrillator after cardiac surgery: Analysis of real-life data from patients at transient risk of sudden cardiac death. Elbayomi M; Weyand M; Seitz T; Harig F Ann Noninvasive Electrocardiol; 2023 Mar; 28(2):e13048. PubMed ID: 36723848 [TBL] [Abstract][Full Text] [Related]
14. Utility of the Wearable Cardioverter-Defibrillator in Patients With Newly Diagnosed Cardiomyopathy: A Decade-Long Single-Center Experience. Singh M; Wang NC; Jain S; Voigt AH; Saba S; Adelstein EC J Am Coll Cardiol; 2015 Dec; 66(23):2607-2613. PubMed ID: 26670060 [TBL] [Abstract][Full Text] [Related]
15. Study of the wearable cardioverter defibrillator in advanced heart-failure patients (SWIFT). Barsheshet A; Kutyifa V; Vamvouris T; Moss AJ; Biton Y; Chen L; Storozynsky E; Wan C; Szymkiewicz SJ; Goldenberg I J Cardiovasc Electrophysiol; 2017 Jul; 28(7):778-784. PubMed ID: 28429542 [TBL] [Abstract][Full Text] [Related]
16. Real life experience with the wearable cardioverter-defibrillator in an international multicenter Registry. El-Battrawy I; Kovacs B; Dreher TC; Klein N; Rosenkaimer S; Röger S; Kuschyk J; Saguner AM; Kowitz J; Erath JW; Duru F; Akin I Sci Rep; 2022 Feb; 12(1):3203. PubMed ID: 35217697 [TBL] [Abstract][Full Text] [Related]
17. Ventricular arrhythmias in patients with newly diagnosed nonischemic cardiomyopathy: Insights from the PROLONG study. Duncker D; König T; Hohmann S; Bauersachs J; Veltmann C Clin Cardiol; 2017 Aug; 40(8):586-590. PubMed ID: 28333373 [TBL] [Abstract][Full Text] [Related]
18. Risk stratification for implantable cardioverter defibrillator therapy: the role of the wearable cardioverter-defibrillator. Klein HU; Goldenberg I; Moss AJ Eur Heart J; 2013 Aug; 34(29):2230-42. PubMed ID: 23729691 [TBL] [Abstract][Full Text] [Related]
19. Wearable cardioverter-defibrillator as a bridge to cardiac transplantation: A national database analysis. Opreanu M; Wan C; Singh V; Salehi N; Ahmad J; Szymkiewicz SJ; Thakur RK J Heart Lung Transplant; 2015 Oct; 34(10):1305-9. PubMed ID: 26094085 [TBL] [Abstract][Full Text] [Related]
20. Protection from outpatient sudden cardiac death following ICD removal using a wearable cardioverter defibrillator. Tanawuttiwat T; Garisto JD; Salow A; Glad JM; Szymkiewicz S; Saltzman HE; Kutalek SP; Carrillo RG Pacing Clin Electrophysiol; 2014 May; 37(5):562-8. PubMed ID: 24762055 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]