23. Couette shearing device for the investigation of shear-induced damage of the primary hemostasis by left ventricular assist devices. Lommel MA; Goubergrits L; Affeld K; Kertzscher U Int J Artif Organs; 2019 Mar; 42(3):143-150. PubMed ID: 30345868 [TBL] [Abstract][Full Text] [Related]
24. Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk. Chivukula VK; Beckman JA; Prisco AR; Dardas T; Lin S; Smith JW; Mokadam NA; Aliseda A; Mahr C Circ Heart Fail; 2018 Apr; 11(4):e004325. PubMed ID: 29666072 [TBL] [Abstract][Full Text] [Related]
25. Effect of rotary blood pump pulsatility on potential parameters of blood compatibility and thrombosis in inflow cannula tips. Wong KC; Büsen M; Benzinger C; Gäng R; Bezema M; Greatrex N; Schmitz-Rode T; Steinseifer U Int J Artif Organs; 2014 Dec; 37(12):875-87. PubMed ID: 25450321 [TBL] [Abstract][Full Text] [Related]
26. Reducing regional flow stasis and improving intraventricular hemodynamics with a tipless inflow cannula design: An in vitro flow visualization study using the EVAHEART LVAD. May-Newman K; Montes R; Campos J; Marquez-Maya N; Vu V; Zebrowski E; Motomura T; Benkowski R Artif Organs; 2019 Sep; 43(9):834-848. PubMed ID: 31038753 [TBL] [Abstract][Full Text] [Related]
27. Computational model of device-induced thrombosis and thromboembolism. Goodman PD; Barlow ET; Crapo PM; Mohammad SF; Solen KA Ann Biomed Eng; 2005 Jun; 33(6):780-97. PubMed ID: 16078618 [TBL] [Abstract][Full Text] [Related]
29. In vitro comparison of the hemocompatibility of two centrifugal left ventricular assist devices. Zayat R; Moza A; Grottke O; Grzanna T; Fechter T; Motomura T; Schmidt-Mewes C; Breuer T; Autschbach R; Rossaint R; Goetzenich A; Bleilevens C J Thorac Cardiovasc Surg; 2019 Feb; 157(2):591-599.e4. PubMed ID: 30414772 [TBL] [Abstract][Full Text] [Related]
30. Small Left Ventricular Size Is an Independent Risk Factor for Ventricular Assist Device Thrombosis. Chivukula VK; Beckman JA; Prisco AR; Lin S; Dardas TF; Cheng RK; Farris SD; Smith JW; Mokadam NA; Mahr C; Aliseda A ASAIO J; 2019 Feb; 65(2):152-159. PubMed ID: 29677037 [TBL] [Abstract][Full Text] [Related]
31. Shear stress evaluation on blood cells using computational fluid dynamics. Mitoh A; Suebe Y; Kashima T; Koyabu E; Sobu E; Okamoto E; Mitamura Y; Nishimura I Biomed Mater Eng; 2020; 31(3):169-178. PubMed ID: 32597794 [TBL] [Abstract][Full Text] [Related]
32. Antithrombogenicity of ventricular assist devices for postoperative myocardial dysfunction. Sato N; Miura M; Watanabe T; Suzuki Y; Hongo T; Nitta S; Mohri H; Yoda R ASAIO Trans; 1988; 34(3):290-3. PubMed ID: 3196522 [TBL] [Abstract][Full Text] [Related]
33. Device thrombosis and pre-clinical blood flow models for assessing antithrombogenic efficacy of drug-device combinations. Sukavaneshvar S Adv Drug Deliv Rev; 2017 Mar; 112():24-34. PubMed ID: 27496706 [TBL] [Abstract][Full Text] [Related]
34. Increased platelet glycoprotein IIb/IIIa activation precedes continuous-flow left ventricular assist device pump thrombosis events. Weiland M; Schuitema J; Jovinge S; Lee S Thromb Res; 2021 May; 201():143-146. PubMed ID: 33798825 [No Abstract] [Full Text] [Related]
35. Bleeding and thrombosis in chronic ventricular assist device therapy: focus on platelets. Koliopoulou A; McKellar SH; Rondina M; Selzman CH Curr Opin Cardiol; 2016 May; 31(3):299-307. PubMed ID: 27054505 [TBL] [Abstract][Full Text] [Related]
36. Science for surgeons: understanding pump thrombogenesis in continuous-flow left ventricular assist devices. de Biasi AR; Manning KB; Salemi A J Thorac Cardiovasc Surg; 2015 Mar; 149(3):667-73. PubMed ID: 25534307 [No Abstract] [Full Text] [Related]
37. Treatment of Left Ventricular Assist Device Thrombosis: Single-Center Experience. Beyazpınar DS; Ersoy Ö; Gültekin B; Aliyev A; Avsever M; Akay HT; Özkan M; Sezgin A; Aşlamacı S Exp Clin Transplant; 2018 Mar; 16 Suppl 1(Suppl 1):165-167. PubMed ID: 29528019 [TBL] [Abstract][Full Text] [Related]
38. Blood trauma potential of the HeartWare Ventricular Assist Device in pediatric patients. Granegger M; Thamsen B; Schlöglhofer T; Lach S; Escher A; Haas T; Meboldt M; Schweiger M; Hübler M; Zimpfer D J Thorac Cardiovasc Surg; 2020 Apr; 159(4):1519-1527.e1. PubMed ID: 31444074 [TBL] [Abstract][Full Text] [Related]
39. Local glycoprotein IIb/IIIa receptor inhibitor delivery from the pump surface attenuates platelet adhesion in continuous flow ventricular assist devices. Linneweber J; Dohmen PM; Kertzscher U; Affeld K; Konertz W Artif Organs; 2008 Oct; 32(10):792-9. PubMed ID: 18959668 [TBL] [Abstract][Full Text] [Related]
40. A two-phase flow approach for modeling blood stasis and estimating the thrombosis potential of a ventricular assist device. Dai WF; Wu P; Liu GM Int J Artif Organs; 2021 Jul; 44(7):471-480. PubMed ID: 33258722 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]