These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 3171755)

  • 1. Tissue response to implanted ceramic-coated titanium alloys in rats.
    Satomi K; Akagawa Y; Nikai H; Tsuru H
    J Oral Rehabil; 1988 Jul; 15(4):339-45. PubMed ID: 3171755
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biocompatibility and biofunctionality of implanted materials.
    Cook SD; Dalton JE
    Alpha Omegan; 1992; 85(4):41-7. PubMed ID: 1308341
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tissue reaction to implanted biomaterials.
    Akagawa Y; Hashimoto M; Kondo N; Yamasaki A; Tsuru H
    J Prosthet Dent; 1985 May; 53(5):681-6. PubMed ID: 3858534
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Quantitative analysis of in vivo tissue responses to titanium-oxide- and hydroxyapatite-coated titanium alloy.
    Hayashi K; Uenoyama K; Matsuguchi N; Sugioka Y
    J Biomed Mater Res; 1991 Apr; 25(4):515-23. PubMed ID: 2050714
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Osteogenic response to porous hydroxyapatite ceramics under the skin of dogs.
    Yamasaki H; Sakai H
    Biomaterials; 1992; 13(5):308-12. PubMed ID: 1318086
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tissue compatibility and stability of a new zirconia ceramic in vivo.
    Ichikawa Y; Akagawa Y; Nikai H; Tsuru H
    J Prosthet Dent; 1992 Aug; 68(2):322-6. PubMed ID: 1501183
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Properties of hydroxyapatite-coated Ti-6Al-4V alloy produced by the ion-plating method.
    Yoshinari M; Ozeki K; Sumii T
    Bull Tokyo Dent Coll; 1991 Nov; 32(4):147-56. PubMed ID: 1668076
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [An experimental study of soft tissue reactions to methacrylate resin, hydroxyapatite and titanium alloy].
    Takashima F; Kurokawa F; Katayama T; Takuma M; Miyauchi S; Maruyama T
    Nihon Hotetsu Shika Gakkai Zasshi; 1987 Oct; 31(5):1202-7. PubMed ID: 3506967
    [No Abstract]   [Full Text] [Related]  

  • 9. The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials.
    Thomas KA; Kay JF; Cook SD; Jarcho M
    J Biomed Mater Res; 1987 Dec; 21(12):1395-414. PubMed ID: 3429474
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bone-bonding behavior of plasma-sprayed coatings of BioglassR, AW-glass ceramic, and tricalcium phosphate on titanium alloy.
    Kitsugi T; Nakamura T; Oka M; Senaha Y; Goto T; Shibuya T
    J Biomed Mater Res; 1996 Feb; 30(2):261-9. PubMed ID: 9019492
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Subcutaneous connective tissue reaction in rats after implantation of restorative dental alloys. Duracast, Idealoy, chromium-cobalt and gold alloys].
    de Deus QD; Martins Vieira RB; de Garrocho A; Wainstein J; Sandy EE; Silva RM; Teixeira RR
    Arq Cent Estud Curso Odontol; 1984 Jul-1985 Jun; 21-22(1-2):75-85. PubMed ID: 6599747
    [No Abstract]   [Full Text] [Related]  

  • 12. Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone.
    Nimb L; Jensen JS; Gotfredsen K
    J Biomed Mater Res; 1995 Dec; 29(12):1477-82. PubMed ID: 8600137
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Histological and histomorphometrical evaluation of the bone reaction to three different titanium alloy and hydroxyapatite coated implants.
    Jansen JA; van der Waerden JP; Wolke JG
    J Appl Biomater; 1993; 4(3):213-9. PubMed ID: 10171978
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Histologic comparison of ceramic and titanium implants in cats.
    Barth E; Johansson C; Albrektsson T
    Int J Oral Maxillofac Implants; 1990; 5(3):227-31. PubMed ID: 2098326
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Materials characteristics of uncoated/ceramic-coated implant materials.
    Lacefield WR
    Adv Dent Res; 1999 Jun; 13():21-6. PubMed ID: 11276742
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bone-implant interface structures after nontapping and tapping insertion of screw-type titanium alloy endosseous implants.
    Satomi K; Akagawa Y; Nikai H; Tsuru H
    J Prosthet Dent; 1988 Mar; 59(3):339-42. PubMed ID: 3162274
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Histological assessment of sintered metal-fibre-web materials.
    Jansen JA; van't Hof MA
    J Biomater Appl; 1994 Jul; 9(1):30-54. PubMed ID: 7983585
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tissue response to percutaneous implants in rabbits.
    Jansen JA; van der Waerden JP; van der Lubbe HB; de Groot K
    J Biomed Mater Res; 1990 Mar; 24(3):295-307. PubMed ID: 2318897
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fracture load of titanium crowns coated with gold or titanium nitride and bonded to low-fusing porcelain.
    Lim HP; Kim JH; Lee KM; Park SW
    J Prosthet Dent; 2011 Mar; 105(3):164-70. PubMed ID: 21356408
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of bioactive glass coated and hydroxyapatite coated titanium dental implants in the human jaw bone.
    Mistry S; Kundu D; Datta S; Basu D
    Aust Dent J; 2011 Mar; 56(1):68-75. PubMed ID: 21332743
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.