These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

70 related articles for article (PubMed ID: 31722378)

  • 1. How to minimize air embolisms during thoracic endovascular aortic repair with Relay Pro?
    Rylski B; Mayer F; Beyersdorf F; Kondov S; Kolowca M; Kreibich M; Czerny M
    Interact Cardiovasc Thorac Surg; 2020 Feb; 30(2):293-295. PubMed ID: 31722378
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Air Embolism During TEVAR: An Additional Flush Port on the Delivery System Pusher Significantly Reduces the Amount of Air Released During Deployment of a Thoracic Stent-Graft in an Experimental Setting.
    Rohlffs F; Tsilimparis N; Trepte C; Kratzberg J; Mogensen J; Debus ES; Kölbel T
    J Endovasc Ther; 2018 Aug; 25(4):435-439. PubMed ID: 29865945
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Air Embolism During TEVAR: Liquid Perfluorocarbon Absorbs Carbon Dioxide in a Combined Flushing Technique and Decreases the Amount of Gas Released From Thoracic Stent-Grafts During Deployment in an Experimental Setting.
    Rohlffs F; Trepte C; Ivancev K; Tsilimparis N; Makaloski V; Debus ES; Kölbel T
    J Endovasc Ther; 2019 Feb; 26(1):76-80. PubMed ID: 30569808
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Air Embolism During TEVAR: Carbon Dioxide Flushing Decreases the Amount of Gas Released from Thoracic Stent-Grafts During Deployment.
    Rohlffs F; Tsilimparis N; Saleptsis V; Diener H; Debus ES; Kölbel T
    J Endovasc Ther; 2017 Feb; 24(1):84-88. PubMed ID: 27798380
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Carbon Dioxide Flushing Technique to Prevent Cerebral Arterial Air Embolism and Stroke During TEVAR.
    Kölbel T; Rohlffs F; Wipper S; Carpenter SW; Debus ES; Tsilimparis N
    J Endovasc Ther; 2016 Apr; 23(2):393-5. PubMed ID: 26896417
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Stroke rate after thoracic endovascular aortic repair using de-airing of stentgrafts with high-volume of saline solution.
    Branzan D; Geisler A; Steiner S; Lautenschlaeger T; Doss M; Matschuck M; Scheinert D; Schmidt A
    Vasa; 2021 Apr; 50(3):186-192. PubMed ID: 33559507
    [No Abstract]   [Full Text] [Related]  

  • 7. Retrospective Comparative Study on Differences in Presence of Gas in the Aneurysm Sac after Endovascular Aortic Aneurysm Repair in Early Postoperative Period between Carbon Dioxide Flushing Technique and Saline Flushing of the Delivery System.
    Eleshra A; Saleptsis V; Spanos K; Rohlffs F; Tsilimparis N; Panuccio G; Makaloski V; Debus ES; Kölbel T
    Ann Vasc Surg; 2019 Nov; 61():310-316. PubMed ID: 31381997
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Distribution of Air Embolization During TEVAR Depends on Landing Zone: Insights From a Pulsatile Flow Model.
    Makaloski V; Rohlffs F; Trepte C; Debus ES; Øhlenschlaeger B; Schmidli J; Kölbel T
    J Endovasc Ther; 2019 Aug; 26(4):448-455. PubMed ID: 31088321
    [No Abstract]   [Full Text] [Related]  

  • 9. Bubble Counter for Measurement of Air Bubbles During Thoracic Stent-Graft Deployment in a Flow Model.
    Makaloski V; Rohlffs F; Spanos K; Debus S; Tsilimparis N; Kölbel T
    J Surg Res; 2018 Dec; 232():121-127. PubMed ID: 30463707
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Late Complication after Thoracic Endovascular Aortic Repair: What Is the Role of an Open Surgical Conversion?
    Davidovic L; Sladojevic M; Koncar I; Markovic M; Ulus T; Ilic N; Dragas M; Cvetic V; Rancic Z
    Ann Vasc Surg; 2018 Feb; 47():238-246. PubMed ID: 28893704
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Results of a multicenter, prospective trial of thoracic endovascular aortic repair for blunt thoracic aortic injury (RESCUE trial).
    Khoynezhad A; Azizzadeh A; Donayre CE; Matsumoto A; Velazquez O; White R;
    J Vasc Surg; 2013 Apr; 57(4):899-905.e1. PubMed ID: 23384495
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surgical conversion after thoracic endovascular aortic repair.
    Canaud L; Alric P; Gandet T; Albat B; Marty-Ané C; Berthet JP
    J Thorac Cardiovasc Surg; 2011 Nov; 142(5):1027-31. PubMed ID: 21397263
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stent graft repair of paraanastomotic aneurysms after open descending thoracic and thoracoabdominal aortic aneurysm repair.
    O'Connor DJ; Vouyouka A; Ellozy SH; Sundick SA; Lemasters P; Marin ML; Faries PL
    Ann Vasc Surg; 2013 Aug; 27(6):693-8. PubMed ID: 23540669
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Change of paradigms in the surgical treatment of complex thoracic aortic disease].
    Herold U; Tsagakis K; Kamler M; Massoudy P; Assenmacher E; Eggebrecht H; Buck T; Jakob H
    Herz; 2006 Aug; 31(5):434-42. PubMed ID: 16944063
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Initial and midterm results of the Bolton Relay Thoracic Aortic Endovascular Pivotal Trial.
    Farber MA; Lee WA; Szeto WY; Panneton JM; Kwolek CJ
    J Vasc Surg; 2017 Jun; 65(6):1556-1566.e1. PubMed ID: 28527926
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New-generation stent grafts for endovascular management of thoracic pseudoaneurysms after aortic coarctation repair.
    Perera AH; Rudarakanchana N; Hamady M; Kashef E; Mireskandari M; Uebing A; Cheshire NJ; Bicknell CD
    J Vasc Surg; 2014 Aug; 60(2):330-6. PubMed ID: 24767711
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Results of the VALOR II trial of the Medtronic Valiant Thoracic Stent Graft.
    Conrad MF; Tuchek J; Freezor R; Bavaria J; White R; Fairman R
    J Vasc Surg; 2017 Aug; 66(2):335-342. PubMed ID: 28366302
    [TBL] [Abstract][Full Text] [Related]  

  • 18. One-Year Results From the SURPASS Observational Registry of the CTAG Stent-Graft With the Active Control System.
    Torsello GF; Argyriou A; Stavroulakis K; Bosiers MJ; Austermann M; Torsello GB;
    J Endovasc Ther; 2020 Jun; 27(3):421-427. PubMed ID: 32193990
    [No Abstract]   [Full Text] [Related]  

  • 19. Commentary: Eliminating Air From Stent-Grafts During Arch Endovascular Therapy: One Step Closer to Reducing Stroke.
    Bechara CF
    J Endovasc Ther; 2019 Feb; 26(1):81-82. PubMed ID: 30572774
    [No Abstract]   [Full Text] [Related]  

  • 20. Transcarotid endoaortic balloon occlusion of the stent graft during reintervention on the thoracoabdominal aorta after thoracic endovascular aortic repair.
    Murzi M; Farneti PA; Tognarelli A; Glauber M
    J Thorac Cardiovasc Surg; 2013 Aug; 146(2):481-2. PubMed ID: 23664691
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.