210 related articles for article (PubMed ID: 31724822)
21. Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support.
Fujino Y; Uchiyama A; Mashimo T; Nishimura M
Respir Care; 2003 Jan; 48(1):38-45. PubMed ID: 12556260
[TBL] [Abstract][Full Text] [Related]
22. Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices.
Villafane MC; Cinnella G; Lofaso F; Isabey D; Harf A; Lemaire F; Brochard L
Anesthesiology; 1996 Dec; 85(6):1341-9. PubMed ID: 8968181
[TBL] [Abstract][Full Text] [Related]
23. Ventilator associated pneumonia: evolving definitions and preventive strategies.
Mietto C; Pinciroli R; Patel N; Berra L
Respir Care; 2013 Jun; 58(6):990-1007. PubMed ID: 23709196
[TBL] [Abstract][Full Text] [Related]
24. Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation.
Uchiyama A; Yoshida T; Yamanaka H; Fujino Y
Respir Care; 2013 Jul; 58(7):1157-69. PubMed ID: 23232731
[TBL] [Abstract][Full Text] [Related]
25. The impact of two distinct endotracheal tube fixation on the formation of pressure ulcer in the intensive care unit: A randomised controlled trial.
Genc A; Yildiz T
Int Wound J; 2022 Oct; 19(6):1594-1603. PubMed ID: 35088531
[TBL] [Abstract][Full Text] [Related]
26. Local Delivery of Mometasone Furoate from an Eluting Endotracheal Tube Reduces Airway Morbidity Following Long-Term Animal Intubation.
Jahshan F; Abu Ammar A; Ertracht O; Eisenbach N; Daoud A; Sela E; Atar S; Zussman E; Fichtman B; Harel A; Gruber M
ACS Appl Bio Mater; 2021 May; 4(5):4131-4139. PubMed ID: 35006827
[TBL] [Abstract][Full Text] [Related]
27. Potential inadequacy of automatic tube compensation to decrease inspiratory work load after at least 48 hours of endotracheal tube use in the clinical setting.
Oto J; Imanaka H; Nakataki E; Ono R; Nishimura M
Respir Care; 2012 May; 57(5):697-703. PubMed ID: 22153219
[TBL] [Abstract][Full Text] [Related]
28. Endotracheal Tube Cuff Pressures in Patients Intubated Prior to Helicopter EMS Transport.
Tennyson J; Ford-Webb T; Weisberg S; LeBlanc D
West J Emerg Med; 2016 Nov; 17(6):721-725. PubMed ID: 27833679
[TBL] [Abstract][Full Text] [Related]
29. The biomechanical efficacy of a hydrogel-based dressing in preventing facial medical device-related pressure ulcers.
Grigatti A; Gefen A
Int Wound J; 2022 Aug; 19(5):1051-1063. PubMed ID: 34623741
[TBL] [Abstract][Full Text] [Related]
30. Best practice in stabilisation of oral endotracheal tubes: a systematic review.
Gardner A; Hughes D; Cook R; Henson R; Osborne S; Gardner G
Aust Crit Care; 2005 Nov; 18(4):158, 160-5. PubMed ID: 18038537
[TBL] [Abstract][Full Text] [Related]
31. Dedicated endotracheal tube for percutaneous tracheostomy.
Tordiglione P; Magni G; Imperiale C; Baisi F; De Blasiis N; Manganozzi V; Rosa G
Eur J Anaesthesiol; 2009 Nov; 26(11):936-9. PubMed ID: 19550339
[TBL] [Abstract][Full Text] [Related]
32. Cuffed endotracheal tubes in pediatric intensive care.
Deakers TW; Reynolds G; Stretton M; Newth CJ
J Pediatr; 1994 Jul; 125(1):57-62. PubMed ID: 8021785
[TBL] [Abstract][Full Text] [Related]
33. Effects of prolonged mechanical ventilation with a closed suction system on endotracheal tube resistance and its reversibility by a closed suction cleaning system.
Adi NA; Tomer NT; Bergman GB; Kishinevsky EK; Wyncoll DW
Anaesth Intensive Care; 2013 Nov; 41(6):728-35. PubMed ID: 24180713
[TBL] [Abstract][Full Text] [Related]
34. Case study involving suctioning of an electromyographic endotracheal tube.
Evanina EY; Hanisak JL
AANA J; 2005 Apr; 73(2):111-3. PubMed ID: 15835830
[TBL] [Abstract][Full Text] [Related]
35. Continuous calculation of intratracheal pressure in the presence of pediatric endotracheal tubes.
Guttmann J; Kessler V; Mols G; Hentschel R; Haberthür C; Geiger K
Crit Care Med; 2000 Apr; 28(4):1018-26. PubMed ID: 10809276
[TBL] [Abstract][Full Text] [Related]
36. Silver-coated endotracheal tubes for prevention of ventilator-associated pneumonia in critically ill patients.
Tokmaji G; Vermeulen H; Müller MC; Kwakman PH; Schultz MJ; Zaat SA
Cochrane Database Syst Rev; 2015 Aug; 2015(8):CD009201. PubMed ID: 26266942
[TBL] [Abstract][Full Text] [Related]
37. Biofilm formation on three different endotracheal tubes: a prospective clinical trial.
Thorarinsdottir HR; Kander T; Holmberg A; Petronis S; Klarin B
Crit Care; 2020 Jun; 24(1):382. PubMed ID: 32600373
[TBL] [Abstract][Full Text] [Related]
38. Tolerability and performance of BIP endotracheal tubes with noble metal alloy coating--a randomized clinical evaluation study.
Björling G; Johansson D; Bergström L; Jalal S; Kohn I; Frostell C; Kalman S
BMC Anesthesiol; 2015 Dec; 15():174. PubMed ID: 26625869
[TBL] [Abstract][Full Text] [Related]
39. Early upper lip pressure ulcer in a preterm neonate.
Makimoto M; Kawasaki Y; Inomata S; Tamura K; Yoshida T
Pediatr Int; 2017 May; 59(5):633-634. PubMed ID: 28326643
[No Abstract] [Full Text] [Related]
40. Effect of lung compliance and endotracheal tube leakage on measurement of tidal volume.
Al-Majed SI; Thompson JE; Watson KF; Randolph AG
Crit Care; 2004 Dec; 8(6):R398-402. PubMed ID: 15566583
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]