These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 31731283)

  • 1. EEG artifact correction strategies for online trial-by-trial analysis.
    de Freitas AM; Sanchez G; Lecaignard F; Maby E; Soares AB; Mattout J
    J Neural Eng; 2020 Jan; 17(1):016035. PubMed ID: 31731283
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of Artifact Subspace Reconstruction for Automatic EEG Artifact Removal.
    Chang CY; Hsu SH; Pion-Tonachini L; Jung TP
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():1242-1245. PubMed ID: 30440615
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of Artifact Subspace Reconstruction for Automatic Artifact Components Removal in Multi-Channel EEG Recordings.
    Chang CY; Hsu SH; Pion-Tonachini L; Jung TP
    IEEE Trans Biomed Eng; 2020 Apr; 67(4):1114-1121. PubMed ID: 31329105
    [TBL] [Abstract][Full Text] [Related]  

  • 4. FORCe: Fully Online and Automated Artifact Removal for Brain-Computer Interfacing.
    Daly I; Scherer R; Billinger M; Müller-Putz G
    IEEE Trans Neural Syst Rehabil Eng; 2015 Sep; 23(5):725-36. PubMed ID: 25134085
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Carbon-wire loop based artifact correction outperforms post-processing EEG/fMRI corrections--A validation of a real-time simultaneous EEG/fMRI correction method.
    van der Meer JN; Pampel A; Van Someren EJW; Ramautar JR; van der Werf YD; Gomez-Herrero G; Lepsien J; Hellrung L; Hinrichs H; Möller HE; Walter M
    Neuroimage; 2016 Jan; 125():880-894. PubMed ID: 26505301
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements.
    Kilicarslan A; Grossman RG; Contreras-Vidal JL
    J Neural Eng; 2016 Apr; 13(2):026013. PubMed ID: 26863159
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Online Automatic Artifact Rejection using the Real-time EEG Source-mapping Toolbox (REST).
    Pion-Tonachini L; Hsu SH; Chang CY; Jung TP; Makeig S
    Annu Int Conf IEEE Eng Med Biol Soc; 2018 Jul; 2018():106-109. PubMed ID: 30440352
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Adapting Artifact Subspace Reconstruction Method for SingleChannel EEG using Signal Decomposition Techniques
    Kaongoen N; Jo S
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-4. PubMed ID: 38083141
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ongoing EEG artifact correction using blind source separation.
    Ille N; Nakao Y; Yano S; Taura T; Ebert A; Bornfleth H; Asagi S; Kozawa K; Itabashi I; Sato T; Sakuraba R; Tsuda R; Kakisaka Y; Jin K; Nakasato N
    Clin Neurophysiol; 2024 Feb; 158():149-158. PubMed ID: 38219404
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Low-complexity hardware design methodology for reliable and automated removal of ocular and muscular artifact from EEG.
    Acharyya A; Jadhav PN; Bono V; Maharatna K; Naik GR
    Comput Methods Programs Biomed; 2018 May; 158():123-133. PubMed ID: 29544778
    [TBL] [Abstract][Full Text] [Related]  

  • 11. EOG artifact correction from EEG recording using stationary subspace analysis and empirical mode decomposition.
    Zeng H; Song A; Yan R; Qin H
    Sensors (Basel); 2013 Nov; 13(11):14839-59. PubMed ID: 24189330
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficient Artifact Removal from Low-Density Wearable EEG using Artifacts Subspace Reconstruction.
    Kumaravel VP; Kartsch V; Benatti S; Vallortigara G; Farella E; Buiatti M
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():333-336. PubMed ID: 34891303
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hybrid wavelet and EMD/ICA approach for artifact suppression in pervasive EEG.
    Bono V; Das S; Jamal W; Maharatna K
    J Neurosci Methods; 2016 Jul; 267():89-107. PubMed ID: 27102040
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Online EEG artifact removal for BCI applications by adaptive spatial filtering.
    Guarnieri R; Marino M; Barban F; Ganzetti M; Mantini D
    J Neural Eng; 2018 Oct; 15(5):056009. PubMed ID: 29952752
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Real-time EEG artifact correction during fMRI using ICA.
    Mayeli A; Zotev V; Refai H; Bodurka J
    J Neurosci Methods; 2016 Dec; 274():27-37. PubMed ID: 27697458
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Corneo-retinal-dipole and eyelid-related eye artifacts can be corrected offline and online in electroencephalographic and magnetoencephalographic signals.
    Kobler RJ; Sburlea AI; Lopes-Dias C; Schwarz A; Hirata M; Müller-Putz GR
    Neuroimage; 2020 Sep; 218():117000. PubMed ID: 32497788
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Surrogate-Based Artifact Removal From Single-Channel EEG.
    Chavez M; Grosselin F; Bussalb A; De Vico Fallani F; Navarro-Sune X
    IEEE Trans Neural Syst Rehabil Eng; 2018 Mar; 26(3):540-550. PubMed ID: 29522398
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Event-related desynchronization during movement attempt and execution in severely paralyzed stroke patients: An artifact removal relevance analysis.
    López-Larraz E; Figueiredo TC; Insausti-Delgado A; Ziemann U; Birbaumer N; Ramos-Murguialday A
    Neuroimage Clin; 2018; 20():972-986. PubMed ID: 30312940
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultrahigh-frequency EEG during fMRI: pushing the limits of imaging-artifact correction.
    Freyer F; Becker R; Anami K; Curio G; Villringer A; Ritter P
    Neuroimage; 2009 Oct; 48(1):94-108. PubMed ID: 19539035
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Riemannian Modification of Artifact Subspace Reconstruction for EEG Artifact Handling.
    Blum S; Jacobsen NSJ; Bleichner MG; Debener S
    Front Hum Neurosci; 2019; 13():141. PubMed ID: 31105543
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.