These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 31732136)

  • 1. Long-Term Electrocardiographic Changes and Clinical Outcomes of Transcatheter Aortic Valve Implantation Recipients Without New Postprocedural Conduction Disturbances.
    Muntané-Carol G; Alméndarez M; Junquera L; Wintzer-Wehekind J; Del Val D; Faroux L; Delarochellière R; Paradis JM; Dumont E; Kalavrouziotis D; Mohammadi S; Côté M; Philippon F; Rodés-Cabau J
    Am J Cardiol; 2020 Jan; 125(1):107-113. PubMed ID: 31732136
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.
    Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.
    Sharma E; Chu AF
    J Interv Card Electrophysiol; 2018 Jan; 51(1):77-86. PubMed ID: 29260369
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Severe conduction defects requiring permanent pacemaker implantation in patients with a new-onset left bundle branch block after transcatheter aortic valve implantation.
    Nijenhuis VJ; Van Dijk VF; Chaldoupi SM; Balt JC; Ten Berg JM
    Europace; 2017 Jun; 19(6):1015-1021. PubMed ID: 28340150
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrophysiological Study-Guided Permanent Pacemaker Implantation in Patients With Conduction Disturbances Following Transcatheter Aortic Valve Implantation.
    Bourenane H; Galand V; Boulmier D; Leclercq C; Leurent G; Bedossa M; Behar N; Pichard C; Polin B; Tomasi J; Verhoye JP; Sharobeem S; Le Guellec M; Donal E; Pavin D; Martins RP; Le Breton H; Auffret V
    Am J Cardiol; 2021 Jun; 149():78-85. PubMed ID: 33753040
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Need for pacemaker implantation in patients with normal QRS duration immediately after transcatheter aortic valve implantation.
    Schoechlin S; Jalil F; Blum T; Ruile P; Hein M; Nührenberg TG; Arentz T; Neumann FJ
    Europace; 2019 Dec; 21(12):1851-1856. PubMed ID: 31578544
    [TBL] [Abstract][Full Text] [Related]  

  • 7. High-degree atrioventricular block in patients with preexisting bundle branch block or bundle branch block occurring during transcatheter aortic valve implantation.
    Egger F; Nürnberg M; Rohla M; Weiss TW; Unger G; Smetana P; Geppert A; Gruber SC; Bambazek A; Falkensammer J; Waldenberger FR; Huber K; Freynhofer MK
    Heart Rhythm; 2014 Dec; 11(12):2176-82. PubMed ID: 25034184
    [TBL] [Abstract][Full Text] [Related]  

  • 8. One-year follow-up of conduction disturbances following transcatheter aortic valve implantation.
    Salizzoni S; Anselmino M; Fornengo C; Giordana F; La Torre M; Moretti C; D'Amico M; Omedé P; Marra S; Rinaldi M; Gaita F
    J Cardiovasc Med (Hagerstown); 2015 Apr; 16(4):296-302. PubMed ID: 25719906
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre-Existent Right Bundle Branch Block.
    van Gils L; Tchetche D; Lhermusier T; Abawi M; Dumonteil N; Rodriguez Olivares R; Molina-Martin de Nicolas J; Stella PR; Carrié D; De Jaegere PP; Van Mieghem NM
    J Am Heart Assoc; 2017 Mar; 6(3):. PubMed ID: 28258051
    [TBL] [Abstract][Full Text] [Related]  

  • 10. One-Year Follow-Up of Conduction Abnormalities After Transcatheter Aortic Valve Implantation With the SAPIEN 3 Valve.
    Dolci G; Vollema EM; van der Kley F; de Weger A; Ajmone Marsan N; Delgado V; Bax JJ
    Am J Cardiol; 2019 Oct; 124(8):1239-1245. PubMed ID: 31439281
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
    Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
    Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve.
    Urena M; Mok M; Serra V; Dumont E; Nombela-Franco L; DeLarochellière R; Doyle D; Igual A; Larose E; Amat-Santos I; Côté M; Cuéllar H; Pibarot P; de Jaegere P; Philippon F; Garcia del Blanco B; Rodés-Cabau J
    J Am Coll Cardiol; 2012 Oct; 60(18):1743-52. PubMed ID: 23040577
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Transcatheter aortic valve implantation and conduction disturbances].
    Ait Said M; Coquard C; Horvilleur J; Manenti V; Fiorina L; Lacotte J; Salerno F
    Ann Cardiol Angeiol (Paris); 2019 Dec; 68(6):443-449. PubMed ID: 31668339
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical Impact of Baseline Right Bundle Branch Block in Patients Undergoing Transcatheter Aortic Valve Replacement.
    Auffret V; Webb JG; Eltchaninoff H; Muñoz-García AJ; Himbert D; Tamburino C; Nombela-Franco L; Nietlispach F; Morís C; Ruel M; Dager AE; Serra V; Cheema AN; Amat-Santos IJ; de Brito FS; Lemos PA; Abizaid A; Sarmento-Leite R; Dumont E; Barbanti M; Durand E; Alonso Briales JH; Vahanian A; Bouleti C; Immè S; Maisano F; Del Valle R; Benitez LM; García Del Blanco B; Puri R; Philippon F; Urena M; Rodés-Cabau J
    JACC Cardiovasc Interv; 2017 Aug; 10(15):1564-1574. PubMed ID: 28734885
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Permanent pacemaker dependency in patients with new left bundle branch block and new first degree atrioventricular block after transcatheter aortic valve implantation.
    Hartrampf B; Jochheim D; Steffen J; Czermak T; Sadoni S; Lemmermöhle E; Klier I; Estner HL; Massberg S; Mehilli J; Lackermair K; Fichtner S
    Sci Rep; 2021 Dec; 11(1):24383. PubMed ID: 34934073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Electrocardiographic Predictors of Long-Term Cardiac Pacing Dependency Following Transcatheter Aortic Valve Implantation.
    Naveh S; Perlman GY; Elitsur Y; Planer D; Gilon D; Leibowitz D; Lotan C; Danenberg H; Alcalai R
    J Cardiovasc Electrophysiol; 2017 Feb; 28(2):216-223. PubMed ID: 27943488
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Predictors and course of high-degree atrioventricular block after transcatheter aortic valve implantation using the CoreValve Revalving System.
    Guetta V; Goldenberg G; Segev A; Dvir D; Kornowski R; Finckelstein A; Hay I; Goldenberg I; Glikson M
    Am J Cardiol; 2011 Dec; 108(11):1600-5. PubMed ID: 21880290
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
    Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
    JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.
    Lenders GD; Collas V; Hernandez JM; Legrand V; Danenberg HD; den Heijer P; Rodrigus IE; Paelinck BP; Vrints CJ; Bosmans JM
    Int J Cardiol; 2014 Oct; 176(3):771-5. PubMed ID: 25147076
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience.
    Kostopoulou A; Karyofillis P; Livanis E; Thomopoulou S; Stefopoulos C; Doudoumis K; Theodorakis G; Voudris V
    Europace; 2016 Jan; 18(1):131-7. PubMed ID: 26060209
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.