These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 31738633)

  • 1. Monitoring the Frequency and Duration of Hypoglycemia in Preterm Infants and Identifying Associated Factors.
    Fernández Martínez MDM; Llorente JLG; de Cabo JM; López MAV; Porcel MDCO; Rubio JDD; Perales AB
    Fetal Pediatr Pathol; 2021 Apr; 40(2):131-141. PubMed ID: 31738633
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Real-time continuous glucose monitoring reduces the duration of hypoglycemia episodes: a randomized trial in very low birth weight neonates.
    Uettwiller F; Chemin A; Bonnemaison E; Favrais G; Saliba E; Labarthe F
    PLoS One; 2015; 10(1):e0116255. PubMed ID: 25590334
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monitoring the incidence, duration and distribution of hyperglycaemia in very-low-birth-weight newborns and identifying associated factors.
    Fernández-Martínez MDM; Gómez-Llorente JL; Momblán-Cabo J; Martin-González M; Calvo-Bonachera M; Olvera-Porcel M; Bonillo-Perales A
    J Perinat Med; 2020 Jul; 48(6):631-637. PubMed ID: 32432567
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experience with Real-Time Continuous Glucose Monitoring in Newborns with Congenital Hyperinsulinemic Hypoglycemia.
    Anık A; Türkmen MK; Akcan AB; Ünüvar T; Öztürk S; Anık A
    Z Geburtshilfe Neonatol; 2021 Apr; 225(2):155-160. PubMed ID: 32746476
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Continuous Glucose Monitoring in Very Preterm Infants: A Randomized Controlled Trial.
    Galderisi A; Facchinetti A; Steil GM; Ortiz-Rubio P; Cavallin F; Tamborlane WV; Baraldi E; Cobelli C; Trevisanuto D
    Pediatrics; 2017 Oct; 140(4):. PubMed ID: 28916591
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The use of a continuous glucose monitoring system in hypoglycemic disorders.
    Conrad SC; Mastrototaro JJ; Gitelman SE
    J Pediatr Endocrinol Metab; 2004 Mar; 17(3):281-8. PubMed ID: 15112904
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Usefulness of continuous glucose monitoring system in detection of hypoglycaemic episodes in patients with diabetes in course of chronic pancreatitis].
    Ruxer J; Mozdzan M; Loba J; Barański M; Ruxer M; Markuszewski L
    Pol Arch Med Wewn; 2005 Oct; 114(4):953-7. PubMed ID: 16789520
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous subcutaneous glucose monitoring is accurate in term and near-term infants at risk of hypoglycaemia.
    Wackernagel D; Dube M; Blennow M; Tindberg Y
    Acta Paediatr; 2016 Aug; 105(8):917-23. PubMed ID: 27203555
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of early glycemic variability on mortality and neurologic outcome of very low birth weight infants: Data from a continuous glucose monitoring system.
    Jagła M; Szymońska I; Starzec K; Kwinta P
    Dev Period Med; 2019; 23(1):7-14. PubMed ID: 30954975
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of the continuous glucose monitoring sensor in preterm infants.
    Beardsall K; Vanhaesebrouck S; Ogilvy-Stuart AL; Vanhole C; VanWeissenbruch M; Midgley P; Thio M; Cornette L; Ossuetta I; Palmer CR; Iglesias I; de Jong M; Gill B; de Zegher F; Dunger DB
    Arch Dis Child Fetal Neonatal Ed; 2013 Mar; 98(2):F136-40. PubMed ID: 22791467
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous Glucose Monitoring in the Management of Neonates With Persistent Hypoglycemia and Congenital Hyperinsulinism.
    Win M; Beckett R; Thomson L; Thankamony A; Beardsall K
    J Clin Endocrinol Metab; 2022 Jan; 107(1):e246-e253. PubMed ID: 34407200
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous glucose monitoring (CGM) in very low birth weight newborns needing parenteral nutrition: validation and glycemic percentiles.
    Perri A; Giordano L; Corsello M; Priolo F; Vento G; Zecca E; Tiberi E
    Ital J Pediatr; 2018 Aug; 44(1):99. PubMed ID: 30134937
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia.
    Nishimura E; Oka S; Ozawa J; Tanaka K; Momose T; Kabe K; Namba F
    Turk Arch Pediatr; 2021 Mar; 56(2):115-120. PubMed ID: 34286319
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early insulin therapy in very-low-birth-weight infants.
    Beardsall K; Vanhaesebrouck S; Ogilvy-Stuart AL; Vanhole C; Palmer CR; van Weissenbruch M; Midgley P; Thompson M; Thio M; Cornette L; Ossuetta I; Iglesias I; Theyskens C; de Jong M; Ahluwalia JS; de Zegher F; Dunger DB
    N Engl J Med; 2008 Oct; 359(18):1873-84. PubMed ID: 18971490
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinically stable very low birthweight infants are at risk for recurrent tissue glucose fluctuations even after fully established enteral nutrition.
    Mola-Schenzle E; Staffler A; Klemme M; Pellegrini F; Molinaro G; Parhofer KG; Messner H; Schulze A; Flemmer AW
    Arch Dis Child Fetal Neonatal Ed; 2015 Mar; 100(2):F126-31. PubMed ID: 25381093
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of continuous glucose monitoring system to detect unrecognized hypoglycemia in children and adolescents with type 1 diabetes.
    Maia FF; Araújo LR
    Arq Bras Endocrinol Metabol; 2005 Aug; 49(4):569-74. PubMed ID: 16358087
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Tight glycemic control with insulin in hyperglycemic preterm babies: a randomized controlled trial.
    Alsweiler JM; Harding JE; Bloomfield FH
    Pediatrics; 2012 Apr; 129(4):639-47. PubMed ID: 22430450
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Very low birth weight preterm infants are at risk for hypoglycemia once on total enteral nutrition.
    Staffler A; Klemme M; Mola-Schenzle E; Mittal R; Schulze A; Flemmer AW
    J Matern Fetal Neonatal Med; 2013 Sep; 26(13):1337-41. PubMed ID: 23528249
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous glucose monitoring in infants of very low birth weight.
    Iglesias Platas I; Thió Lluch M; Pociello Almiñana N; Morillo Palomo A; Iriondo Sanz M; Krauel Vidal X
    Neonatology; 2009; 95(3):217-23. PubMed ID: 18971588
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of retrospective calibration algorithms on hypoglycemia detection in newborn infants using continuous glucose monitoring.
    Signal M; Le Compte A; Harris DL; Weston PJ; Harding JE; Chase JG;
    Diabetes Technol Ther; 2012 Oct; 14(10):883-90. PubMed ID: 22856622
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.