BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

308 related articles for article (PubMed ID: 31740884)

  • 1. Diagnostic accuracy and associated complications of percutaneous computed tomography guided core needle biopsy of pulmonary lesions using coaxial technique.
    Sattar A; Khan SA; Al-Qamari N; Adel H; Adil SO
    J Pak Med Assoc; 2019 Nov; 69(11):1711-1713. PubMed ID: 31740884
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions.
    Li Y; Du Y; Yang HF; Yu JH; Xu XX
    Clin Radiol; 2013 Jan; 68(1):e43-8. PubMed ID: 23177650
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostic accuracy and complications of CT-guided core needle lung biopsy of solid and part-solid lesions.
    Yun S; Kang H; Park S; Kim BS; Park JG; Jung MJ
    Br J Radiol; 2018 Jul; 91(1088):20170946. PubMed ID: 29770737
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years.
    Yin Z; Liang Z; Li P; Wang Q
    Eur Radiol; 2017 Aug; 27(8):3401-3407. PubMed ID: 28050696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Complications in CT-Guided, Semi-Automatic Coaxial Core Biopsy of Potentially Malignant Pulmonary Lesions.
    Schulze R; Seebacher G; Enderes B; Kugler G; Fischer JR; Graeter TP
    Rofo; 2015 Aug; 187(8):697-702. PubMed ID: 26062172
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy.
    Andrade JR; Rocha RD; Falsarella PM; Rahal Junior A; Santos RSD; Franceschini JP; Fernando HC; Garcia RG
    J Bras Pneumol; 2018; 44(4):307-314. PubMed ID: 30328929
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic accuracy and complication rates of percutaneous CT-guided coaxial needle biopsy of pulmonary lesions.
    Sarajlic V; Vesnic S; Udovicic-Gagula D; Kuric H; Akhan O
    Diagn Interv Radiol; 2021 Jul; 27(4):553-557. PubMed ID: 33769291
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Transthoracic Computed Tomography-Guided Lung Nodule Biopsy: Comparison of Core Needle and Fine Needle Aspiration Techniques.
    Sangha BS; Hague CJ; Jessup J; O'Connor R; Mayo JR
    Can Assoc Radiol J; 2016 Aug; 67(3):284-9. PubMed ID: 27005931
    [TBL] [Abstract][Full Text] [Related]  

  • 9. CT-guided core needle biopsy of pleural lesions: evaluating diagnostic yield and associated complications.
    Niu XK; Bhetuwal A; Yang HF
    Korean J Radiol; 2015; 16(1):206-12. PubMed ID: 25598692
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CT-guided fine-needle aspiration and core needle biopsies of pulmonary lesions: a single-center experience with 750 biopsies in Japan.
    Takeshita J; Masago K; Kato R; Hata A; Kaji R; Fujita S; Katakami N
    AJR Am J Roentgenol; 2015 Jan; 204(1):29-34. PubMed ID: 25539234
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of CT-Guided Core-Needle Biopsy in Diagnosis of Thoracic Lesions Suspicious for Primitive Malignancy of the Lung: A Five-Year Retrospective Analysis.
    Baratella E; Cernic S; Minelli P; Furlan G; Crimì F; Rocco S; Ruaro B; Cova MA
    Tomography; 2022 Nov; 8(6):2828-2838. PubMed ID: 36548528
    [TBL] [Abstract][Full Text] [Related]  

  • 12. CT-guided percutaneous core-needle biopsy of pancreatic masses: comparison of the standard mesenteric/retroperitoneal versus the trans-organ approaches.
    Hsu MY; Pan KT; Chen CM; Lui KW; Chu SY; Lin YY; Hung CF; Huang YT; Tseng JH
    Clin Radiol; 2016 Jun; 71(6):507-12. PubMed ID: 27040800
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Full core technology versus notch sampling technology: evaluation of the diagnostic accuracy and the risk of a pneumothorax after transthoracic needle biopsy of suspicious lung lesions.
    Schroeder C; Loebelenz LI; Heverhagen JT; Noeldge G; Brönnimann MP; Kim SY
    Acta Radiol; 2022 Jan; 63(1):35-41. PubMed ID: 33356359
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic accuracy and safety of CT-guided percutaneous lung biopsy with a coaxial cutting needle for the diagnosis of lung cancer in patients with UIP pattern.
    Kim DY; Sun JS; Kim EY; Park KJ; You S
    Sci Rep; 2022 Sep; 12(1):15682. PubMed ID: 36127437
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Coaxial technique-promoted diagnostic accuracy of CT-guided percutaneous cutting needle biopsy for small and deep lung lesions.
    Zhang L; Shi L; Xiao Z; Qiu H; Peng P; Zhang M
    PLoS One; 2018; 13(2):e0192920. PubMed ID: 29447239
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic Accuracy of CT-Guided Core Needle Biopsy for Thin-Walled Cavitary Pulmonary Lesions.
    Shin KE; Park JS; Lee JW
    AJR Am J Roentgenol; 2021 Feb; 216(2):369-375. PubMed ID: 33295816
    [No Abstract]   [Full Text] [Related]  

  • 17. Diagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules.
    Yang W; Sun W; Li Q; Yao Y; Lv T; Zeng J; Liang W; Zhou X; Song Y
    PLoS One; 2015; 10(6):e0131373. PubMed ID: 26110775
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computed tomography fluoroscopy-guided cutting needle biopsy of pulmonary nodules ≤8 mm: A retrospective study including 117 nodules.
    Zhao Y; Matsui Y; Hiraki T; Iguchi T; Tomita K; Uka M; Gobara H; Toyooka S; Kanazawa S
    Eur J Radiol; 2020 Apr; 125():108903. PubMed ID: 32088660
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Trans-thoracic biopsy of lung lesions: FNAB or CNB? Our experience and review of the literature.
    Capalbo E; Peli M; Lovisatti M; Cosentino M; Mariani P; Berti E; Cariati M
    Radiol Med; 2014 Aug; 119(8):572-94. PubMed ID: 24297594
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies.
    Uzun Ç; Akkaya Z; Düşünceli Atman E; Üstüner E; Peker E; Gülpınar B; Elhan AH; Ceyhan K; Atasoy KÇ
    Diagn Interv Radiol; 2017; 23(2):137-143. PubMed ID: 28029638
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.