These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 31748616)

  • 1. A novel nondestructive diagnostic method for mega-electron-volt ultrafast electron diffraction.
    Yang X; Li J; Fedurin M; Smaluk V; Yu L; Wu L; Wan W; Zhu Y; Shaftan T
    Sci Rep; 2019 Nov; 9(1):17223. PubMed ID: 31748616
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accurate prediction of mega-electron-volt electron beam properties from UED using machine learning.
    Zhang Z; Yang X; Huang X; Li J; Shaftan T; Smaluk V; Song M; Wan W; Wu L; Zhu Y
    Sci Rep; 2021 Jul; 11(1):13890. PubMed ID: 34230561
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Toward monochromated sub-nanometer UEM and femtosecond UED.
    Yang X; Wan W; Wu L; Smaluk V; Shaftan T; Zhu Y
    Sci Rep; 2020 Sep; 10(1):16171. PubMed ID: 32999357
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A compact tunable quadrupole lens for brighter and sharper ultra-fast electron diffraction imaging.
    Yang X; Yu L; Smaluk V; Wang G; Hidaka Y; Shaftan T; Doom L; Padrazo D; Li J; Fedurin M; Wan W; Zhu Y
    Sci Rep; 2019 Mar; 9(1):5115. PubMed ID: 30914665
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Toward fully automated UED operation using two-stage machine learning model.
    Zhang Z; Yang X; Huang X; Shaftan T; Smaluk V; Song M; Wan W; Wu L; Zhu Y
    Sci Rep; 2022 Mar; 12(1):4240. PubMed ID: 35273341
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noninvasive time-sorting in radio frequency-compressed ultrafast electron diffraction.
    Zhao L; Wu J; Wang Z; Tang H; Zou X; Jiang T; Zhu P; Xiang D; Zhang J
    Struct Dyn; 2021 Jul; 8(4):044303. PubMed ID: 34327258
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Femtosecond gas-phase mega-electron-volt ultrafast electron diffraction.
    Shen X; Nunes JPF; Yang J; Jobe RK; Li RK; Lin MF; Moore B; Niebuhr M; Weathersby SP; Wolf TJA; Yoneda C; Guehr M; Centurion M; Wang XJ
    Struct Dyn; 2019 Sep; 6(5):054305. PubMed ID: 31649964
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mega-electron-volt ultrafast electron diffraction at SLAC National Accelerator Laboratory.
    Weathersby SP; Brown G; Centurion M; Chase TF; Coffee R; Corbett J; Eichner JP; Frisch JC; Fry AR; Gühr M; Hartmann N; Hast C; Hettel R; Jobe RK; Jongewaard EN; Lewandowski JR; Li RK; Lindenberg AM; Makasyuk I; May JE; McCormick D; Nguyen MN; Reid AH; Shen X; Sokolowski-Tinten K; Vecchione T; Vetter SL; Wu J; Yang J; Dürr HA; Wang XJ
    Rev Sci Instrum; 2015 Jul; 86(7):073702. PubMed ID: 26233391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A compact streak camera for 150 fs time resolved measurement of bright pulses in ultrafast electron diffraction.
    Kassier GH; Haupt K; Erasmus N; Rohwer EG; von Bergmann HM; Schwoerer H; Coelho SM; Auret FD
    Rev Sci Instrum; 2010 Oct; 81(10):105103. PubMed ID: 21034115
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental demonstration of high quality MeV ultrafast electron diffraction.
    Li R; Tang C; Du Y; Huang W; Du Q; Shi J; Yan L; Wang X
    Rev Sci Instrum; 2009 Aug; 80(8):083303. PubMed ID: 19725647
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative agreement between dynamical rocking curves in ultrafast electron diffraction for x-ray lasers.
    Malin LE; Graves WS; Holl M; Spence JCH; Nanni EA; Li RK; Shen X; Weathersby S
    Ultramicroscopy; 2021 Apr; 223():113211. PubMed ID: 33582644
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Four-Dimensional Ultrafast Electron Microscopy: Insights into an Emerging Technique.
    Adhikari A; Eliason JK; Sun J; Bose R; Flannigan DJ; Mohammed OF
    ACS Appl Mater Interfaces; 2017 Jan; 9(1):3-16. PubMed ID: 27976852
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Infrared PINEM developed by diffraction in 4D UEM.
    Liu H; Baskin JS; Zewail AH
    Proc Natl Acad Sci U S A; 2016 Feb; 113(8):2041-6. PubMed ID: 26848135
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultracold electron source for single-shot, ultrafast electron diffraction.
    van der Geer SB; de Loos MJ; Vredenbregt EJ; Luiten OJ
    Microsc Microanal; 2009 Aug; 15(4):282-9. PubMed ID: 19575829
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Method for developing a sub-10 fs ultrafast electron diffraction technology.
    Kim HW; Baek IH; Shin J; Park S; Bark HS; Oang KY; Jang KH; Lee K; Vinokurov N; Jeong YU
    Struct Dyn; 2020 May; 7(3):034301. PubMed ID: 32566696
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Femtosecond mega-electron-volt electron microdiffraction.
    Shen X; Li RK; Lundström U; Lane TJ; Reid AH; Weathersby SP; Wang XJ
    Ultramicroscopy; 2018 Jan; 184(Pt A):172-176. PubMed ID: 28915441
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Instrumental development of a quasi-relativistic ultrashort electron beam source for electron diffractions and spectroscopies.
    Shin YM; Figora M
    Rev Sci Instrum; 2017 Oct; 88(10):103302. PubMed ID: 29092527
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved temporal resolution in ultrafast electron diffraction measurements through THz compression and time-stamping.
    Othman MAK; Gabriel AE; Snively EC; Kozina ME; Shen X; Ji F; Lewis S; Weathersby S; Vasireddy P; Luo D; Wang X; Hoffmann MC; Nanni EA
    Struct Dyn; 2024 Mar; 11(2):024311. PubMed ID: 38655563
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Breaking 50 Femtosecond Resolution Barrier in MeV Ultrafast Electron Diffraction with a Double Bend Achromat Compressor.
    Qi F; Ma Z; Zhao L; Cheng Y; Jiang W; Lu C; Jiang T; Qian D; Wang Z; Zhang W; Zhu P; Zou X; Wan W; Xiang D; Zhang J
    Phys Rev Lett; 2020 Apr; 124(13):134803. PubMed ID: 32302182
    [TBL] [Abstract][Full Text] [Related]  

  • 20. rf streak camera based ultrafast relativistic electron diffraction.
    Musumeci P; Moody JT; Scoby CM; Gutierrez MS; Tran T
    Rev Sci Instrum; 2009 Jan; 80(1):013302. PubMed ID: 19191429
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.