These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
410 related articles for article (PubMed ID: 31759392)
1. Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis. Kizaki K; Shanmugaraj A; Yamashita F; Simunovic N; Duong A; Khanna V; Ayeni OR BMC Musculoskelet Disord; 2019 Nov; 20(1):561. PubMed ID: 31759392 [TBL] [Abstract][Full Text] [Related]
2. Functional outcomes in patient specific instrumentation vs. conventional instrumentation for total knee arthroplasty; a systematic review and meta-analysis of prospective studies. Rudran B; Magill H; Ponugoti N; Williams A; Ball S BMC Musculoskelet Disord; 2022 Jul; 23(1):702. PubMed ID: 35870913 [TBL] [Abstract][Full Text] [Related]
3. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Anderl W; Pauzenberger L; Kölblinger R; Kiesselbach G; Brandl G; Laky B; Kriegleder B; Heuberer P; Schwameis E Knee Surg Sports Traumatol Arthrosc; 2016 Jan; 24(1):102-11. PubMed ID: 25326759 [TBL] [Abstract][Full Text] [Related]
4. Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial. Kosse NM; Heesterbeek PJC; Schimmel JJP; van Hellemondt GG; Wymenga AB; Defoort KC Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1792-1799. PubMed ID: 29181560 [TBL] [Abstract][Full Text] [Related]
5. Can a Single-Use and Patient-Specific Instrumentation Be Reliably Used in Primary Total Knee Arthroplasty? A Multicenter Controlled Study. Abane L; Zaoui A; Anract P; Lefevre N; Herman S; Hamadouche M J Arthroplasty; 2018 Jul; 33(7):2111-2118. PubMed ID: 29576488 [TBL] [Abstract][Full Text] [Related]
6. No difference in mid-term survival and clinical outcome between patient-specific and conventional instrumented total knee arthroplasty: a randomized controlled trial. Schotanus MGM; Boonen B; van der Weegen W; Hoekstra H; van Drumpt R; Borghans R; Vos R; van Rhijn L; Kort NP Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1463-1468. PubMed ID: 29725747 [TBL] [Abstract][Full Text] [Related]
7. Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty. Huijbregts HJ; Khan RJ; Sorensen E; Fick DP; Haebich S Acta Orthop; 2016 Aug; 87(4):386-94. PubMed ID: 27249110 [TBL] [Abstract][Full Text] [Related]
8. Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup analysis of randomised trials. Woon JTK; Zeng ISL; Calliess T; Windhagen H; Ettinger M; Waterson HB; Toms AD; Young SW Arch Orthop Trauma Surg; 2018 Sep; 138(9):1293-1303. PubMed ID: 29961093 [TBL] [Abstract][Full Text] [Related]
9. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty. Schotanus MGM; Thijs E; Heijmans M; Vos R; Kort NP Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2659-2668. PubMed ID: 28698929 [TBL] [Abstract][Full Text] [Related]
10. Patellofemoral Arthroplasty Results in Better Time-weighted Patient-reported Outcomes After 6 Years than TKA: A Randomized Controlled Trial. Odgaard A; Kappel A; Madsen F; Kristensen PW; Stephensen S; Attarzadeh AP Clin Orthop Relat Res; 2022 Sep; 480(9):1707-1718. PubMed ID: 35315804 [TBL] [Abstract][Full Text] [Related]
11. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty. Laende EK; Richardson CG; Dunbar MJ Bone Joint J; 2019 Aug; 101-B(8):929-940. PubMed ID: 31362561 [TBL] [Abstract][Full Text] [Related]
12. Similar postoperative patient-reported outcome in both second generation patellofemoral arthroplasty and total knee arthroplasty for treatment of isolated patellofemoral osteoarthritis: a systematic review. Bunyoz KI; Lustig S; Troelsen A Knee Surg Sports Traumatol Arthrosc; 2019 Jul; 27(7):2226-2237. PubMed ID: 30264243 [TBL] [Abstract][Full Text] [Related]
13. Accuracy of MRI-based vs. CT-based patient-specific instrumentation in total knee arthroplasty: A meta-analysis. An VV; Sivakumar BS; Phan K; Levy YD; Bruce WJ J Orthop Sci; 2017 Jan; 22(1):116-120. PubMed ID: 27823847 [TBL] [Abstract][Full Text] [Related]
14. Patient-specific instrumentation does not improve alignment in total knee arthroplasty. Russell R; Brown T; Huo M; Jones R J Knee Surg; 2014 Dec; 27(6):501-4. PubMed ID: 24504637 [TBL] [Abstract][Full Text] [Related]
15. Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases. Schoenmakers DAL; Schotanus MGM; Boonen B; Kort NP Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1800-1804. PubMed ID: 29147744 [TBL] [Abstract][Full Text] [Related]
16. Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis. Tibesku CO; Haas SB; Saunders C; Harwood DA Arch Orthop Trauma Surg; 2023 Jul; 143(7):4379-4393. PubMed ID: 36449066 [TBL] [Abstract][Full Text] [Related]
17. Component alignment and clinical outcome following total knee arthroplasty: a randomised controlled trial comparing an intramedullary alignment system with patient-specific instrumentation. Huijbregts HJ; Khan RJ; Fick DP; Hall MJ; Punwar SA; Sorensen E; Reid MJ; Vedove SD; Haebich S Bone Joint J; 2016 Aug; 98-B(8):1043-9. PubMed ID: 27482015 [TBL] [Abstract][Full Text] [Related]
18. Comparison of the clinical and patient-reported outcomes between medial stabilized and posterior stabilized total knee arthroplasty: A systematic review and meta-analysis. Liu X; Liu Y; Li B; Wang L; Wang Y; Liu J Knee; 2022 Jun; 36():9-19. PubMed ID: 35405624 [TBL] [Abstract][Full Text] [Related]
19. [Meta analysis of three-dimensional printing patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty]. Ren JT; Xu C; Wang JS; Liu XL Zhonghua Wai Ke Za Zhi; 2017 Oct; 55(10):775-781. PubMed ID: 29050180 [No Abstract] [Full Text] [Related]
20. Favourable rotational alignment outcomes in PSI knee arthroplasty: A Level 1 systematic review and meta-analysis. Mannan A; Smith TO Knee; 2016 Mar; 23(2):186-90. PubMed ID: 26782300 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]