These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 31764892)

  • 1. HLA Alloimmunization Following Ventricular Assist Device Support Across the Age Spectrum.
    Halpin AM; Nahirniak S; Campbell PM; Urschel S; Kim DH; West LJ; Pidorochynski T; Buchholz H; Conway J
    Transplantation; 2019 Dec; 103(12):2715-2724. PubMed ID: 31764892
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantification, identification, and relevance of anti-human leukocyte antigen antibodies formed in association with the berlin heart ventricular assist device in children.
    O'Connor MJ; Harville TO; Rhodes-Clark B; Pye SE; Knecht KR; Imamura M; Frazier EA; Morrow WR
    Transplantation; 2013 Jun; 95(12):1542-7. PubMed ID: 23778570
    [TBL] [Abstract][Full Text] [Related]  

  • 3. HLA and MICA allosensitization patterns among patients supported by ventricular assist devices.
    Askar M; Hsich E; Reville P; Nowacki AS; Baldwin W; Bakdash S; Daghstani J; Zhang A; Klingman L; Smedira N; Moazami N; Taylor DO; Starling RC; Gonzalez-Stawinski G
    J Heart Lung Transplant; 2013 Dec; 32(12):1241-8. PubMed ID: 24075503
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Factors associated with anti-human leukocyte antigen antibodies in patients supported with continuous-flow devices and effect on probability of transplant and post-transplant outcomes.
    Alba AC; Tinckam K; Foroutan F; Nelson LM; Gustafsson F; Sander K; Bruunsgaard H; Chih S; Hayes H; Rao V; Delgado D; Ross HJ
    J Heart Lung Transplant; 2015 May; 34(5):685-92. PubMed ID: 25638296
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Panel reactive antibody monitoring in pediatric patients undergoing ventricle assist device as a bridge to heart transplantation.
    Grutter G; Amodeo A; Brancaccio G; Parisi F
    Artif Organs; 2013 May; 37(5):435-8. PubMed ID: 23419042
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ventricular assist device-associated anti-human leukocyte antigen antibody sensitization in pediatric patients bridged to heart transplantation.
    O'Connor MJ; Menteer J; Chrisant MR; Monos D; Lind C; Levine S; Gaynor JW; Hanna BD; Paridon SM; Ravishankar C; Kaufman BD
    J Heart Lung Transplant; 2010 Jan; 29(1):109-16. PubMed ID: 20123248
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical significance of anti-HLA antibodies associated with ventricular assist device use in pediatric patients: A United Network for Organ Sharing database analysis.
    Magdo HS; Schumacher KR; Yu S; Gajarski RJ; Friedland-Little JM
    Pediatr Transplant; 2017 Aug; 21(5):. PubMed ID: 28568969
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sensitisation and post-transplant course after the implantation of ventricular assist device.
    Malickaite R; Rucinskas K; Staneviciene A; Miniauskas S; Maneikiene V; Zuoziene G; Sirvydis V
    Interact Cardiovasc Thorac Surg; 2009 Mar; 8(3):339-42; discussion 342-3. PubMed ID: 19098066
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of ventricular assist device-mediated sensitization in the bridge-to-heart-transplantation patient.
    Kwon MH; Zhang JQ; Schaenman JM; Cadeiras M; Gjertson DW; Krystal CA; Laks H; Ardehali A; Deng MC; Shemin RJ; Reed EF
    J Thorac Cardiovasc Surg; 2015 Apr; 149(4):1161-6. PubMed ID: 25702320
    [TBL] [Abstract][Full Text] [Related]  

  • 10. HLA alloimmunization in patients requiring ventricular assist device support.
    McKenna DH; Eastlund T; Segall M; Noreen HJ; Park S
    J Heart Lung Transplant; 2002 Nov; 21(11):1218-24. PubMed ID: 12431496
    [TBL] [Abstract][Full Text] [Related]  

  • 11. HLA sensitization in pediatric pre-transplant cardiac patients supported by mechanical assist devices: the utility of Luminex.
    Yang J; Schall C; Smith D; Kreuser L; Zamberlan M; King K; Gajarski R
    J Heart Lung Transplant; 2009 Feb; 28(2):123-9. PubMed ID: 19201336
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Human Leukocyte Antigen Antibody Sampling in Ventricular Assist Device Recipients: Are We Talking?
    Khoury M; Pidborochynski T; Halpin A; Campbell P; Urschel S; Kim D; West L; Buchholz H; Conway J
    Transplant Proc; 2021 Sep; 53(7):2377-2381. PubMed ID: 34412914
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Factors influencing transfusion-associated HLA sensitization in patients bridged to heart transplantation using ventricular assist device.
    Elkind J; Sobczyk J; Ostberg-Braun O; Silva Enciso J; Adler E; Morris GP
    Clin Transplant; 2020 Jan; 34(1):e13772. PubMed ID: 31845395
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Allosensitization does not alter post-transplant outcomes in pediatric patients bridged to transplant with a ventricular assist device.
    Castleberry C; Zafar F; Thomas T; Khan MS; Bryant R; Chin C; Morales DL; Lorts A
    Pediatr Transplant; 2016 Jun; 20(4):559-64. PubMed ID: 27102953
    [TBL] [Abstract][Full Text] [Related]  

  • 15. HLA sensitization in ventricular assist device recipients: does type of device make a difference?
    Kumpati GS; Cook DJ; Blackstone EH; Rajeswaran J; Abdo AS; Young JB; Starling RC; Smedira NG; McCarthy PM
    J Thorac Cardiovasc Surg; 2004 Jun; 127(6):1800-7. PubMed ID: 15173739
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Human leukocyte antigen sensitization in ventricular assist device recipients: a lesser risk with the DeBakey axial pump.
    Grinda JM; Bricourt MO; Amrein C; Salvi S; Guillemain R; Francois A; Guibourt P; Deloche A; Fabiani JN
    Ann Thorac Surg; 2005 Sep; 80(3):945-8. PubMed ID: 16122460
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ventricular assist device elicits serum natural IgG that correlates with the development of primary graft dysfunction following heart transplantation.
    See SB; Clerkin KJ; Kennel PJ; Zhang F; Weber MP; Rogers KJ; Chatterjee D; Vasilescu ER; Vlad G; Naka Y; Restaino SW; Farr MA; Topkara VK; Colombo PC; Mancini DM; Schulze PC; Levin B; Zorn E
    J Heart Lung Transplant; 2017 Aug; 36(8):862-870. PubMed ID: 28431981
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prospective examination of HLA sensitization after VAD implantation in children and adults.
    Townsend M; Pidborochynski T; Cantor RS; Khoury M; Campbell P; Halpin A; Urschel S; Kim D; Nahirniak S; West LJ; Buchholz H; Conway J
    Transpl Immunol; 2023 Oct; 80():101892. PubMed ID: 37419373
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Human leukocyte antigen sensitization in pediatric patients exposed to mechanical circulatory support.
    Hong BJ; Delaney M; Guynes A; Warner P; McMullan DM; Kemna MS; Boucek RJ; Law YM
    ASAIO J; 2014; 60(3):317-21. PubMed ID: 24469294
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Post-transplant outcomes in pediatric ventricular assist device patients: A PediMACS-Pediatric Heart Transplant Study linkage analysis.
    Sutcliffe DL; Pruitt E; Cantor RS; Godown J; Lane J; Turrentine MW; Law SP; Lantz JL; Kirklin JK; Bernstein D; Blume ED
    J Heart Lung Transplant; 2018 Jun; 37(6):715-722. PubMed ID: 29373179
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.