These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

274 related articles for article (PubMed ID: 31765399)

  • 1. The impact of short-term machine perfusion on the risk of cancer recurrence after rat liver transplantation with donors after circulatory death.
    Oldani G; Peloso A; Slits F; Gex Q; Delaune V; Orci LA; van de Looij Y; Colin DJ; Germain S; de Vito C; Rubbia-Brandt L; Lacotte S; Toso C
    PLoS One; 2019; 14(11):e0224890. PubMed ID: 31765399
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hypothermic oxygenated perfusion (HOPE) protects from biliary injury in a rodent model of DCD liver transplantation.
    Schlegel A; Graf R; Clavien PA; Dutkowski P
    J Hepatol; 2013 Nov; 59(5):984-91. PubMed ID: 23820408
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hypothermic Oxygenated Liver Perfusion (HOPE) Prevents Tumor Recurrence in Liver Transplantation From Donation After Circulatory Death.
    Mueller M; Kalisvaart M; O'Rourke J; Shetty S; Parente A; Muller X; Isaac J; Muellhaupt B; Muiesan P; Shah T; Clavien PA; Schlegel A; Dutkowski P
    Ann Surg; 2020 Nov; 272(5):759-765. PubMed ID: 32889870
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hypothermic oxygenated perfusion protects from mitochondrial injury before liver transplantation.
    Schlegel A; Muller X; Mueller M; Stepanova A; Kron P; de Rougemont O; Muiesan P; Clavien PA; Galkin A; Meierhofer D; Dutkowski P
    EBioMedicine; 2020 Oct; 60():103014. PubMed ID: 32979838
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Warm vs. cold perfusion techniques to rescue rodent liver grafts.
    Schlegel A; Kron P; Graf R; Dutkowski P; Clavien PA
    J Hepatol; 2014 Dec; 61(6):1267-75. PubMed ID: 25086285
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Normothermic machine perfusion reduces bile duct injury and improves biliary epithelial function in rat donor livers.
    Op den Dries S; Karimian N; Westerkamp AC; Sutton ME; Kuipers M; Wiersema-Buist J; Ottens PJ; Kuipers J; Giepmans BN; Leuvenink HG; Lisman T; Porte RJ
    Liver Transpl; 2016 Jul; 22(7):994-1005. PubMed ID: 26946466
    [TBL] [Abstract][Full Text] [Related]  

  • 7. End-ischemic machine perfusion reduces bile duct injury in donation after circulatory death rat donor livers independent of the machine perfusion temperature.
    Westerkamp AC; Mahboub P; Meyer SL; Hottenrott M; Ottens PJ; Wiersema-Buist J; Gouw AS; Lisman T; Leuvenink HG; Porte RJ
    Liver Transpl; 2015 Oct; 21(10):1300-11. PubMed ID: 26097213
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pre-retrieval reperfusion decreases cancer recurrence after rat ischemic liver graft transplantation.
    Oldani G; Crowe LA; Orci LA; Slits F; Rubbia-Brandt L; de Vito C; Morel P; Mentha G; Berney T; Vallée JP; Lacotte S; Toso C
    J Hepatol; 2014 Aug; 61(2):278-85. PubMed ID: 24713189
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The role of sequential normothermic regional perfusion and end-ischemic normothermic machine perfusion in liver transplantation from very extended uncontrolled donation after cardiocirculatory death.
    Ghinolfi D; Melandro F; Torri F; Esposito M; Bindi M; Biancofiore G; Basta G; Del Turco S; Lazzeri C; Rotondo MI; Peris A; De Simone P
    Artif Organs; 2023 Feb; 47(2):432-440. PubMed ID: 36461895
    [TBL] [Abstract][Full Text] [Related]  

  • 10. One hour hypothermic oxygenated perfusion (HOPE) protects nonviable liver allografts donated after cardiac death.
    de Rougemont O; Breitenstein S; Leskosek B; Weber A; Graf R; Clavien PA; Dutkowski P
    Ann Surg; 2009 Nov; 250(5):674-83. PubMed ID: 19806056
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hypothermic, oxygenated perfusion (HOPE) provides cardioprotection via succinate oxidation prior to normothermic perfusion in a rat model of donation after circulatory death (DCD).
    Wyss RK; Méndez Carmona N; Arnold M; Segiser A; Mueller M; Dutkowski P; Carrel TP; Longnus SL
    Am J Transplant; 2021 Mar; 21(3):1003-1011. PubMed ID: 32786170
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preliminary Experience With Hypothermic Oxygenated Machine Perfusion in an Italian Liver Transplant Center.
    Dondossola D; Lonati C; Zanella A; Maggioni M; Antonelli B; Reggiani P; Gatti S; Rossi G
    Transplant Proc; 2019; 51(1):111-116. PubMed ID: 30736971
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Combined liver-kidney perfusion enhances protective effects of normothermic perfusion on liver grafts from donation after cardiac death.
    He X; Ji F; Zhang Z; Tang Y; Yang L; Huang S; Li W; Su Q; Xiong W; Zhu Z; Wang L; Lv L; Yao J; Zhang L; Zhang L; Guo Z
    Liver Transpl; 2018 Jan; 24(1):67-79. PubMed ID: 29024427
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Impact of machine perfusion preservation of liver grafts from donation after cardiac death.
    Matsuno N; Uchida K; Furukawa H
    Transplant Proc; 2014 May; 46(4):1099-103. PubMed ID: 24815138
    [TBL] [Abstract][Full Text] [Related]  

  • 15. First Comparison of Hypothermic Oxygenated PErfusion Versus Static Cold Storage of Human Donation After Cardiac Death Liver Transplants: An International-matched Case Analysis.
    Dutkowski P; Polak WG; Muiesan P; Schlegel A; Verhoeven CJ; Scalera I; DeOliveira ML; Kron P; Clavien PA
    Ann Surg; 2015 Nov; 262(5):764-70; discussion 770-1. PubMed ID: 26583664
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of Hypothermic Oxygenated Machine Perfusion on Hepatocellular Carcinoma Recurrence after Liver Transplantation.
    Rigo F; De Stefano N; Patrono D; De Donato V; Campi L; Turturica D; Doria T; Sciannameo V; Berchialla P; Tandoi F; Romagnoli R
    J Pers Med; 2023 Apr; 13(5):. PubMed ID: 37240873
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sequential Use of Normothermic Regional and Ex Situ Machine Perfusion in Donation After Circulatory Death Liver Transplant.
    Ghinolfi D; Dondossola D; Rreka E; Lonati C; Pezzati D; Cacciatoinsilla A; Kersik A; Lazzeri C; Zanella A; Peris A; Maggioni M; Biancofiore G; Reggiani P; Morganti R; De Simone P; Rossi G
    Liver Transpl; 2021 Feb; 27(3):385-402. PubMed ID: 32949117
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hypothermic oxygenated machine perfusion reduces bile duct reperfusion injury after transplantation of donation after circulatory death livers.
    van Rijn R; van Leeuwen OB; Matton APM; Burlage LC; Wiersema-Buist J; van den Heuvel MC; de Kleine RHJ; de Boer MT; Gouw ASH; Porte RJ
    Liver Transpl; 2018 May; 24(5):655-664. PubMed ID: 29369470
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An Oxygenated and Transportable Machine Perfusion System Fully Rescues Liver Grafts Exposed to Lethal Ischemic Damage in a Pig Model of DCD Liver Transplantation.
    Compagnon P; Levesque E; Hentati H; Disabato M; Calderaro J; Feray C; Corlu A; Cohen JL; Ben Mosbah I; Azoulay D
    Transplantation; 2017 Jul; 101(7):e205-e213. PubMed ID: 28403128
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of Short-Term Normothermic and Subnormothermic Perfusion After Cold Preservation on Liver Transplantation From Donors After Cardiac Death.
    Yamada S; Miyagi S; Hara Y; Kakizaki Y; Sasajima H; Mitsui K; Fujimori K; Unno M; Kamei T; Goto M
    Transplant Proc; 2020; 52(6):1639-1642. PubMed ID: 32471629
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.