BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

192 related articles for article (PubMed ID: 31767442)

  • 1. Advantages of expulsion-proof pins in the treatment of olecranon fractures with tension band wiring: Comparison with a control group.
    Di Francia R; Letissier H; Le Nen D; Lefèvre C; Dubrana F; Stindel É
    Orthop Traumatol Surg Res; 2019 Dec; 105(8):1593-1599. PubMed ID: 31767442
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Surgical interventions for treating fractures of the olecranon in adults.
    Matar HE; Ali AA; Buckley S; Garlick NI; Atkinson HD
    Cochrane Database Syst Rev; 2014 Nov; 2014(11):CD010144. PubMed ID: 25426876
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tension-band wiring of displaced stable olecranon fractures with Eyelet-pins in the elderly: A series of 17 cases.
    Tsujino S; Tsujino A; Matsubara M
    Orthop Traumatol Surg Res; 2021 Dec; 107(8):103076. PubMed ID: 34563734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Treatment of isolated fractures of the olecranon: percutaneous double-screw fixation versus conventional tension band wiring].
    Uhlmann M; Barg A; Valderrabano V; Weber O; Wirtz DC; Pagenstert G
    Unfallchirurg; 2014 Jul; 117(7):614-23. PubMed ID: 23754551
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Double tension band wiring for treatment of olecranon fractures.
    Kim W; Choi S; Yoon JO; Park HY; Kim SH; Kim JS
    J Hand Surg Am; 2014 Dec; 39(12):2438-43. PubMed ID: 25447004
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures.
    Kim JY; Lee YH; Gong HS; Lee SL; Lee SK; Baek GH
    J Hand Surg Am; 2013 Sep; 38(9):1762-7. PubMed ID: 23849734
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The ideal implant for Mayo 2A olecranon fractures? An economic evaluation.
    Tan BYJ; Pereira MJ; Ng J; Kwek EBK
    J Shoulder Elbow Surg; 2020 Nov; 29(11):2347-2352. PubMed ID: 32569869
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques.
    Tarallo L; Mugnai R; Adani R; Capra F; Zambianchi F; Catani F
    Arch Orthop Trauma Surg; 2014 Aug; 134(8):1107-14. PubMed ID: 24935660
    [TBL] [Abstract][Full Text] [Related]  

  • 9. K-wire position in tension-band wiring technique affects stability of wires and long-term outcome in surgical treatment of olecranon fractures.
    van der Linden SC; van Kampen A; Jaarsma RL
    J Shoulder Elbow Surg; 2012 Mar; 21(3):405-11. PubMed ID: 22036542
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tension band wiring versus locking plate fixation for simple, two-part Mayo 2A olecranon fractures: a comparison of post-operative outcomes, complications, reoperations and economics.
    Powell AJ; Farhan-Alanie OM; McGraw IWW
    Musculoskelet Surg; 2019 Aug; 103(2):155-160. PubMed ID: 30006804
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Factors influencing K-wire migration in tension-band wiring of olecranon fractures.
    Saeed ZM; Trickett RW; Yewlett AD; Matthews TJ
    J Shoulder Elbow Surg; 2014 Aug; 23(8):1181-6. PubMed ID: 24875733
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of tension band wiring and plate fixation in Mayo type 2A olecranon fractures.
    Çağlar C; Akçaalan S; Özaslan Hİ; Yağar H; Uğurlu M
    Jt Dis Relat Surg; 2021; 32(1):85-92. PubMed ID: 33463422
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures.
    Midtgaard KS; Søreide E; Brattgjerd JE; Moatshe G; Madsen JE; Flugsrud GB
    J Shoulder Elbow Surg; 2020 Jun; 29(6):1242-1248. PubMed ID: 32139286
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surgical technique in tension band wiring method for selected comminuted olecranon fractures.
    Okamoto M; Namba J; Kuriyama K; Miyamura S; Yokoi H; Yamamoto K
    Eur J Orthop Surg Traumatol; 2020 Feb; 30(2):237-242. PubMed ID: 31538271
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of sutures as Kirschner wire and tension-band wire for olecranon fractures: a technical note.
    Henseler JF; van der Zwaal P; Dijkstra PD
    J Orthop Surg (Hong Kong); 2014 Dec; 22(3):440-2. PubMed ID: 25550036
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimally invasive tension band wiring technique for olecranon fractures.
    Takada N; Kato K; Fukuta M; Wada I; Otsuka T
    Tech Hand Up Extrem Surg; 2013 Dec; 17(4):199-201. PubMed ID: 24240623
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cost Assessment of Plating Versus Tension Band Wiring Constructs for Treating Mayo Type 2A Olecranon Fractures.
    Steadman JN; Stephens AR; Zhang C; Presson AP; Kazmers NH
    J Hand Surg Am; 2022 Apr; 47(4):311-319. PubMed ID: 35131112
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Olecranon fracture fixation with a new implant: biomechanical and clinical considerations.
    Koslowsky TC; Mader K; Dargel J; Schadt R; Koebke J; Pennig D
    Injury; 2009 Jun; 40(6):618-24. PubMed ID: 19394014
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon.
    Wilson J; Bajwa A; Kamath V; Rangan A
    J Bone Joint Surg Br; 2011 Feb; 93(2):245-50. PubMed ID: 21282766
    [TBL] [Abstract][Full Text] [Related]  

  • 20. More metalwork removals in patients with olecranon fracture treated by tension band wiring than plate fixation-a propensity score matching analysis.
    Qiu L; Li Y; Wu H; Chen R; Zhang Z; Wang X; Huang Y
    BMC Musculoskelet Disord; 2021 Aug; 22(1):692. PubMed ID: 34389015
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.