BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1077 related articles for article (PubMed ID: 31770297)

  • 21. Image Quality Assessment for Clinical Cadmium Telluride-Based Photon-Counting Computed Tomography Detector in Cadaveric Wrist Imaging.
    Grunz JP; Huflage H; Heidenreich JF; Ergün S; Petersilka M; Allmendinger T; Bley TA; Petritsch B
    Invest Radiol; 2021 Dec; 56(12):785-790. PubMed ID: 33882030
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Energy-integrating-detector multi-energy CT: Implementation and a phantom study.
    Ren L; Allmendinger T; Halaweish A; Schmidt B; Flohr T; McCollough CH; Yu L
    Med Phys; 2021 Sep; 48(9):4857-4871. PubMed ID: 33988849
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Multi-energy CT imaging for large patients using dual-source photon-counting detector CT.
    Tao S; Marsh JF; Tao A; Michalak GJ; Rajendran K; McCollough CH; Leng S
    Phys Med Biol; 2020 Aug; 65(17):17NT01. PubMed ID: 32503022
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Dual-source photon counting detector CT with a tin filter: a phantom study on iodine quantification performance.
    Tao A; Huang R; Tao S; Michalak GJ; McCollough CH; Leng S
    Phys Med Biol; 2019 May; 64(11):115019. PubMed ID: 31018197
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Myeloma bone disease imaging on a 1st-generation clinical photon-counting detector CT vs. 2nd-generation dual-source dual-energy CT.
    Winkelmann MT; Hagen F; Le-Yannou L; Weiss J; Riffel P; Gutjahr R; Faby S; Nikolaou K; Horger M
    Eur Radiol; 2023 Apr; 33(4):2415-2425. PubMed ID: 36350390
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Technical note: Exploring the detectability of coronary calcification using ultra-high-resolution photon-counting-detector CT.
    Chang S; Ren L; Tang S; Marsh JF; Hsieh S; McCollough CH; Leng S
    Med Phys; 2023 Nov; 50(11):6836-6843. PubMed ID: 37650788
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study.
    Zhou W; Lane JI; Carlson ML; Bruesewitz MR; Witte RJ; Koeller KK; Eckel LJ; Carter RE; McCollough CH; Leng S
    AJNR Am J Neuroradiol; 2018 Sep; 39(9):1733-1738. PubMed ID: 30093479
    [TBL] [Abstract][Full Text] [Related]  

  • 28. First Clinical Photon-counting Detector CT System: Technical Evaluation.
    Rajendran K; Petersilka M; Henning A; Shanblatt ER; Schmidt B; Flohr TG; Ferrero A; Baffour F; Diehn FE; Yu L; Rajiah P; Fletcher JG; Leng S; McCollough CH
    Radiology; 2022 Apr; 303(1):130-138. PubMed ID: 34904876
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Photon-counting CT of elbow joint fractures: image quality in a simulated post-trauma setting with off-center positioning.
    Sonnow L; Salimova N; Behrendt L; Wacker FK; Örgel M; Plagge J; Weidemann F
    Eur Radiol Exp; 2023 Mar; 7(1):15. PubMed ID: 36967394
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study.
    Tao S; Rajendran K; McCollough CH; Leng S
    Med Phys; 2019 Sep; 46(9):4105-4115. PubMed ID: 31215659
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Virtual Noncontrast Imaging of the Liver Using Photon-Counting Detector Computed Tomography: A Systematic Phantom and Patient Study.
    Sartoretti T; Mergen V; Higashigaito K; Eberhard M; Alkadhi H; Euler A
    Invest Radiol; 2022 Jul; 57(7):488-493. PubMed ID: 35136003
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Full field-of-view, high-resolution, photon-counting detector CT: technical assessment and initial patient experience.
    Rajendran K; Petersilka M; Henning A; Shanblatt E; Marsh J; Thorne J; Schmidt B; Flohr T; Fletcher J; McCollough C; Leng S
    Phys Med Biol; 2021 Oct; 66(20):. PubMed ID: 34271558
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma.
    Baffour FI; Huber NR; Ferrero A; Rajendran K; Glazebrook KN; Larson NB; Kumar S; Cook JM; Leng S; Shanblatt ER; McCollough CH; Fletcher JG
    Radiology; 2023 Jan; 306(1):229-236. PubMed ID: 36066364
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison of Radiation Dose and Image Quality of Pediatric High-Resolution Chest CT Between Photon-Counting Detector CT and Energy-Integrated Detector CT: A Matched Study.
    Siegel MJ; Bugenhagen SM; Sanchez A; Kim S; Abadia A; Ramirez-Giraldo JC
    AJR Am J Roentgenol; 2023 Sep; 221(3):363-371. PubMed ID: 37095666
    [No Abstract]   [Full Text] [Related]  

  • 35. Feasibility of photon-counting CT for femoroacetabular impingement syndrome evaluation: lower radiation dose and improved diagnostic confidence.
    Ferrero A; Powell GM; Adaaquah DK; Rajendran K; Thorne JE; Krych AJ; Horst KK; McCollough CH; Baffour FI
    Skeletal Radiol; 2023 Sep; 52(9):1651-1659. PubMed ID: 36971838
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Photon-counting CT for diagnosis of acute pulmonary embolism: potential for contrast medium and radiation dose reduction.
    Pannenbecker P; Huflage H; Grunz JP; Gruschwitz P; Patzer TS; Weng AM; Heidenreich JF; Bley TA; Petritsch B
    Eur Radiol; 2023 Nov; 33(11):7830-7839. PubMed ID: 37311805
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency.
    Krauss B; Grant KL; Schmidt BT; Flohr TG
    Invest Radiol; 2015 Feb; 50(2):114-8. PubMed ID: 25373305
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Photon-Counting Detector Computed Tomography Versus Energy-Integrating Detector Computed Tomography for Coronary Artery Calcium Quantitation.
    McCollough CH; Winfree TN; Melka EF; Rajendran K; Carter RE; Leng S
    J Comput Assist Tomogr; 2024 Mar-Apr 01; 48(2):212-216. PubMed ID: 37801651
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Dedicated convolutional neural network for noise reduction in ultra-high-resolution photon-counting detector computed tomography.
    Huber NR; Ferrero A; Rajendran K; Baffour F; Glazebrook KN; Diehn FE; Inoue A; Fletcher JG; Yu L; Leng S; McCollough CH
    Phys Med Biol; 2022 Sep; 67(17):. PubMed ID: 35944556
    [No Abstract]   [Full Text] [Related]  

  • 40. Low-contrast detectability of photon-counting-detector CT at different scan modes and image types in comparison with energy-integrating-detector CT.
    Fan M; Zhou Z; Wellinghoff J; McCollough CH; Yu L
    J Med Imaging (Bellingham); 2024 Dec; 11(Suppl 1):S12803. PubMed ID: 38799271
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 54.