These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 31773000)

  • 1. Determination of the Range and Spread-Out Bragg Peak Width of Proton Beams Using a Large-Volume Liquid Scintillator.
    Henry T; Robertson D; Therriault-Proulx F; Beddar S
    Int J Part Ther; 2017; 4(1):1-6. PubMed ID: 31773000
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SU-E-T-161: SOBP Beam Analysis Using Light Output of Scintillation Plate Acquired by CCD Camera.
    Cho S; Lee S; Shin J; Min B; Chung K; Shin D; Lim Y; Park S
    Med Phys; 2012 Jun; 39(6Part12):3740. PubMed ID: 28517823
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Passively scattered proton beam entrance dosimetry with a plastic scintillation detector.
    Wootton L; Holmes C; Sahoo N; Beddar S
    Phys Med Biol; 2015 Feb; 60(3):1185-98. PubMed ID: 25591037
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams.
    Alsanea F; Darne C; Robertson D; Beddar S
    Phys Med Biol; 2020 Apr; 65(7):075005. PubMed ID: 32079001
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.
    Archambault L; Poenisch F; Sahoo N; Robertson D; Lee A; Gillin MT; Mohan R; Beddar S
    Med Phys; 2012 Mar; 39(3):1239-46. PubMed ID: 22380355
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector.
    Hui C; Robertson D; Alsanea F; Beddar S
    Biomed Phys Eng Express; 2015 Aug; 1(2):. PubMed ID: 27274863
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation.
    Faddegon BA; Shin J; Castenada CM; Ramos-Méndez J; Daftari IK
    Med Phys; 2015 Jul; 42(7):4199-210. PubMed ID: 26133619
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A mathematical expression for depth-light curves of therapeutic proton beams in a quenching scintillator.
    Kelleter L; Jolly S
    Med Phys; 2020 Jun; 47(5):2300-2308. PubMed ID: 32072646
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quenching correction for volumetric scintillation dosimetry of proton beams.
    Robertson D; Mirkovic D; Sahoo N; Beddar S
    Phys Med Biol; 2013 Jan; 58(2):261-73. PubMed ID: 23257200
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional dose-distribution measurement of therapeutic carbon-ion beams using a ZnS scintillator sheet.
    Yogo K; Tsuneda M; Horita R; Souda H; Matsumura A; Ishiyama H; Hayakawa K; Kanai T; Yamamoto S
    J Radiat Res; 2021 Sep; 62(5):825-832. PubMed ID: 33998657
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluations of a flat-panel based compact daily quality assurance device for proton pencil beam scanning (PBS) system.
    Su Z; Hsi W; Forthomme J; Rossomme S
    Phys Med; 2020 Dec; 80():243-250. PubMed ID: 33202363
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Characteristics of optically stimulated luminescence dosimeters in the spread-out Bragg peak region of clinical proton beams.
    Kerns JR; Kry SF; Sahoo N
    Med Phys; 2012 Apr; 39(4):1854-63. PubMed ID: 22482607
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Spread-out Bragg peak proton FLASH irradiation using a clinical synchrocyclotron: Proof of concept and ion chamber characterization.
    Darafsheh A; Hao Y; Zhao X; Zwart T; Wagner M; Evans T; Reynoso F; Zhao T
    Med Phys; 2021 Aug; 48(8):4472-4484. PubMed ID: 34077590
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dose- rather than fluence-averaged LET should be used as a single-parameter descriptor of proton beam quality for radiochromic film dosimetry.
    Resch AF; Heyes PD; Fuchs H; Bassler N; Georg D; Palmans H
    Med Phys; 2020 Jun; 47(5):2289-2299. PubMed ID: 32166764
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Deep learning proton beam range estimation model for quality assurance based on two-dimensional scintillated light distributions in simulations.
    Lee E; Cho B; Kwak J; Jeong C; Park MJ; Kim SW; Song SY; Goh Y
    Med Phys; 2023 Nov; 50(11):7203-7213. PubMed ID: 37517077
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Benchmarking a GATE/Geant4 Monte Carlo model for proton beams in magnetic fields.
    Padilla-Cabal F; Alejandro Fragoso J; Franz Resch A; Georg D; Fuchs H
    Med Phys; 2020 Jan; 47(1):223-233. PubMed ID: 31661559
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quality assurance of proton beams using a multilayer ionization chamber system.
    Dhanesar S; Sahoo N; Kerr M; Taylor MB; Summers P; Zhu XR; Poenisch F; Gillin M
    Med Phys; 2013 Sep; 40(9):092102. PubMed ID: 24007171
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography.
    Kroll F; Pawelke J; Karsch L
    Med Phys; 2013 Aug; 40(8):082104. PubMed ID: 23927341
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monitor unit prediction model for wobbling proton therapy with ridge filters.
    Jo K; Chung E; Han Y; Ahn SH; Sheen H; Cho S
    Med Phys; 2021 Dec; 48(12):8107-8116. PubMed ID: 34628659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.