These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 31779446)

  • 1. Plasma diagnostic tools for ECR ion sources-What can we learn from these experiments for the next generation sources.
    Tarvainen O; Kalvas T; Koivisto H; Kronholm R; Marttinen M; Sakildien M; Toivanen V; Izotov I; Skalyga V; Angot J
    Rev Sci Instrum; 2019 Nov; 90(11):113321. PubMed ID: 31779446
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fourth generation electron cyclotron resonance ion sources.
    Lyneis CM; Leitner D; Todd DS; Sabbi G; Prestemon S; Caspi S; Ferracin P
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02A321. PubMed ID: 18315111
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Nb3Sn superconducting magnets for electron cyclotron resonance ion sources.
    Ferracin P; Caspi S; Felice H; Leitner D; Lyneis CM; Prestemon S; Sabbi GL; Todd DS
    Rev Sci Instrum; 2010 Feb; 81(2):02A309. PubMed ID: 20192330
    [TBL] [Abstract][Full Text] [Related]  

  • 4. First results from the new RIKEN superconducting electron cyclotron resonance ion source (invited).
    Nakagawa T; Higurashi Y; Ohnishi J; Aihara T; Tamura M; Uchiyama A; Okuno H; Kusaka K; Kidera M; Ikezawa E; Fujimaki M; Sato Y; Watanabe Y; Komiyama M; Kase M; Goto A; Kamigaito O; Yano Y
    Rev Sci Instrum; 2010 Feb; 81(2):02A320. PubMed ID: 20192341
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Superconducting magnets for the RAON electron cyclotron resonance ion source.
    Choi S; Kim Y; Hong IS; Jeon D
    Rev Sci Instrum; 2014 Feb; 85(2):02A906. PubMed ID: 24593485
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and investigations of the superconducting magnet system for the multipurpose superconducting electron cyclotron resonance ion source.
    Tinschert K; Lang R; Mäder J; Rossbach J; Spädtke P; Komorowski P; Meyer-Reumers M; Krischel D; Fischer B; Ciavola G; Gammino S; Celona L
    Rev Sci Instrum; 2012 Feb; 83(2):02A319. PubMed ID: 22380166
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL.
    Zhao HW; Sun LT; Zhang XZ; Guo XH; Cao Y; Lu W; Zhang ZM; Yuan P; Song MT; Zhao HY; Jin T; Shang Y; Zhan WL; Wei BW; Xie DZ
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02A315. PubMed ID: 18315105
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Superconducting ECR ion source: From 24-28 GHz SECRAL to 45 GHz fourth generation ECR.
    Zhao HW; Sun LT; Guo JW; Zhang WH; Lu W; Wu W; Wu BM; Sabbi G; Juchno M; Hafalia A; Ravaioli E; Xie DZ
    Rev Sci Instrum; 2018 May; 89(5):052301. PubMed ID: 29864795
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a new superconducting Electron Cyclotron Resonance Ion Source for operations up to 18 GHz at LBNL.
    Xie DZ; Benitez JY; Caspi S; Hodgkinson A; Lyneis CM; Phair LW; Prestemon SO; Strohmeier MM; Thuillier TP; Todd DS
    Rev Sci Instrum; 2014 Feb; 85(2):02A922. PubMed ID: 24593501
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities.
    Tarvainen O; Laulainen J; Komppula J; Kronholm R; Kalvas T; Koivisto H; Izotov I; Mansfeld D; Skalyga V
    Rev Sci Instrum; 2015 Feb; 86(2):023301. PubMed ID: 25725830
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Study of hydrogen ECR plasma in a simple mirror magnetic trap heated by 75 GHz pulsed gyrotron radiation.
    Skalyga VA; Izotov IV; Sidorov AV; Golubev SV; Razin SV
    Rev Sci Instrum; 2017 Mar; 88(3):033503. PubMed ID: 28372417
    [TBL] [Abstract][Full Text] [Related]  

  • 12. New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited).
    Zhao HW; Sun LT; Lu W; Zhang XZ; Guo XH; Cao Y; Zhao HY; Feng YC; Li JY; Ma HY; Shang Y; Ma BH; Wang H; Li XX; Xie DZ
    Rev Sci Instrum; 2010 Feb; 81(2):02A202. PubMed ID: 20192321
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Glow plasma trigger for electron cyclotron resonance ion sources.
    Vodopianov AV; Golubev SV; Izotov IV; Nikolaev AG; Oks EM; Savkin KP; Yushkov GY
    Rev Sci Instrum; 2010 Feb; 81(2):02A305. PubMed ID: 20192326
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A status report of the multipurpose superconducting electron cyclotron resonance ion source.
    Ciavola G; Gammino S; Barbarino S; Celona L; Consoli F; Gallo G; Maimone F; Mascali D; Passarello S; Galatà A; Tinschert K; Spaedtke P; Lang R; Maeder J; Rossbach J; Koivisto H; Savonen M; Koponen T; Suominen P; Ropponen T; Baruè C; Lechartier M; Beijers JP; Brandenburg S; Kremers HR; Vanrooyen D; Kuchler D; Scrivens R; Schachter L; Dobrescu S; Stiebing K
    Rev Sci Instrum; 2008 Feb; 79(2 Pt 2):02A326. PubMed ID: 18315116
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Diagnostic techniques of minimum-B ECR ion source plasma instabilities.
    Toivanen V; Bhaskar BS; Izotov IV; Koivisto H; Tarvainen O
    Rev Sci Instrum; 2022 Jan; 93(1):013302. PubMed ID: 35104948
    [TBL] [Abstract][Full Text] [Related]  

  • 16. First results of the 2.45 GHz Oshima electron cyclotron resonance ion source.
    Asaji T; Nakamura T; Furuse M; Hitobo T; Uchida T; Muramatsu M; Kato Y
    Rev Sci Instrum; 2016 Feb; 87(2):02A730. PubMed ID: 26931948
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The electron cyclotron resonance ion source with arc-shaped coils concept (invited).
    Koivisto H; Suominen P; Tarvainen O; Spädtke P
    Rev Sci Instrum; 2012 Feb; 83(2):02A312. PubMed ID: 22380159
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Towards a better comprehension of plasma formation and heating in high performances electron cyclotron resonance ion sources (invited).
    Mascali D; Gammino S; Celona L; Ciavola G
    Rev Sci Instrum; 2012 Feb; 83(2):02A336. PubMed ID: 22380183
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurements of the energy distribution of electrons lost from the minimum B-field-The effect of instabilities and two-frequency heating.
    Izotov I; Tarvainen O; Skalyga V; Mansfeld D; Koivisto H; Kronholm R; Toivanen V; Mironov V
    Rev Sci Instrum; 2020 Jan; 91(1):013502. PubMed ID: 32012519
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Upper hybrid resonance heating experiments by X-mode microwaves on electron cyclotron resonance ion source.
    Kato Y; Nishiokada T; Hamada K; Onishi K; Takeda T; Okumura K; Omori T; Kubo W; Ishihara M; Harisaki S
    Rev Sci Instrum; 2020 Jan; 91(1):013315. PubMed ID: 32012523
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.