135 related articles for article (PubMed ID: 31785124)
1. Ultrasonographic confirmation of endotracheal intubation in extremely low birthweigh infants - secondary publication.
Takeuchi S; Arai J; Nagafuji M; Hinata A; Kamakura T; Hoshino Y; Yukitake Y
Pediatr Int; 2020 Feb; 62(2):175-179. PubMed ID: 31785124
[TBL] [Abstract][Full Text] [Related]
2. Ultrasonography for endotracheal tube position in infants and children.
Jaeel P; Sheth M; Nguyen J
Eur J Pediatr; 2017 Mar; 176(3):293-300. PubMed ID: 28091777
[TBL] [Abstract][Full Text] [Related]
3. Ideal endotracheal tube insertion depth in neonates with a birthweight less than 750 g.
Takeuchi S; Arai J; Nagafuji M; Hinata A; Kamakura T; Hoshino Y; Yukitake Y
Pediatr Int; 2020 Aug; 62(8):932-936. PubMed ID: 32239786
[TBL] [Abstract][Full Text] [Related]
4. Capnography rapidly confirmed correct endotracheal tube placement during resuscitation of extremely low birthweight babies (< 1000 g).
Salthe J; Kristiansen SM; Sollid S; Oglaend B; Søreide E
Acta Anaesthesiol Scand; 2006 Sep; 50(8):1033-6. PubMed ID: 16923102
[TBL] [Abstract][Full Text] [Related]
5. Determination of optimal endotracheal tube tip depth from the gum in neonates by X-ray and ultrasound.
Zaytseva A; Kurepa D; Ahn S; Weinberger B
J Matern Fetal Neonatal Med; 2020 Jun; 33(12):2075-2080. PubMed ID: 30332898
[No Abstract] [Full Text] [Related]
6. Endotracheal intubation attempts during neonatal resuscitation: success rates, duration, and adverse effects.
O'Donnell CP; Kamlin CO; Davis PG; Morley CJ
Pediatrics; 2006 Jan; 117(1):e16-21. PubMed ID: 16396845
[TBL] [Abstract][Full Text] [Related]
7. Assessment of flow waves and colorimetric CO2 detector for endotracheal tube placement during neonatal resuscitation.
Schmölzer GM; Poulton DA; Dawson JA; Kamlin CO; Morley CJ; Davis PG
Resuscitation; 2011 Mar; 82(3):307-12. PubMed ID: 21167628
[TBL] [Abstract][Full Text] [Related]
8. Evaluating Endotracheal Tube Depth in Infants Weighing Less Than 1 Kilogram.
Bartle RM; Miller AG; Diez AJ; Smith PB; Gentile MA; Puia-Dumitrescu M
Respir Care; 2019 Mar; 64(3):243-247. PubMed ID: 30206127
[TBL] [Abstract][Full Text] [Related]
9. Failed endotracheal intubation and adverse outcomes among extremely low birth weight infants.
Wallenstein MB; Birnie KL; Arain YH; Yang W; Yamada NK; Huffman LC; Palma JP; Chock VY; Shaw GM; Stevenson DK
J Perinatol; 2016 Feb; 36(2):112-5. PubMed ID: 26540244
[TBL] [Abstract][Full Text] [Related]
10. Comparison of a colorimetric end-tidal CO2 detector and an esophageal aspiration device for verifying endotracheal tube placement in the prehospital setting: a six-month experience.
Schaller RJ; Huff JS; Zahn A
Prehosp Disaster Med; 1997; 12(1):57-63. PubMed ID: 10166376
[TBL] [Abstract][Full Text] [Related]
11. A novel training simulator for portable ultrasound identification of incorrect newborn endotracheal tube placement - observational diagnostic accuracy study protocol.
Merali HS; Tessaro MO; Ali KQ; Morris SK; Soofi SB; Ariff S
BMC Pediatr; 2019 Nov; 19(1):434. PubMed ID: 31722685
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of a Capno-Flo resuscitator during transport of critically ill children.
Bhende MS; Allen WD
Pediatr Emerg Care; 2002 Dec; 18(6):414-6. PubMed ID: 12488833
[TBL] [Abstract][Full Text] [Related]
13. Role of ultrasound in confirmation of endotracheal tube in neonates: a review.
Sharma D; Tabatabaii SA; Farahbakhsh N
J Matern Fetal Neonatal Med; 2019 Apr; 32(8):1359-1367. PubMed ID: 29117819
[TBL] [Abstract][Full Text] [Related]
14. Techniques to ascertain correct endotracheal tube placement in neonates.
Schmölzer GM; Roehr CC
Cochrane Database Syst Rev; 2014 Sep; (9):CD010221. PubMed ID: 25217732
[TBL] [Abstract][Full Text] [Related]
15. Confirmation of endotracheal tube placement after intubation using the ultrasound sliding lung sign.
Weaver B; Lyon M; Blaivas M
Acad Emerg Med; 2006 Mar; 13(3):239-44. PubMed ID: 16495415
[TBL] [Abstract][Full Text] [Related]
16. Real-time tracheal ultrasonography for confirmation of endotracheal tube placement during cardiopulmonary resuscitation.
Chou HC; Chong KM; Sim SS; Ma MH; Liu SH; Chen NC; Wu MC; Fu CM; Wang CH; Lee CC; Lien WC; Chen SC
Resuscitation; 2013 Dec; 84(12):1708-12. PubMed ID: 23851048
[TBL] [Abstract][Full Text] [Related]
17. Delivery room continuous positive airway pressure/positive end-expiratory pressure in extremely low birth weight infants: a feasibility trial.
Finer NN; Carlo WA; Duara S; Fanaroff AA; Donovan EF; Wright LL; Kandefer S; Poole WK;
Pediatrics; 2004 Sep; 114(3):651-7. PubMed ID: 15342835
[TBL] [Abstract][Full Text] [Related]
18. Optimal Insertion Depth for Endotracheal Tubes in Extremely Low-Birth-Weight Infants.
Leung C
Pediatr Crit Care Med; 2018 Apr; 19(4):328-331. PubMed ID: 29406381
[TBL] [Abstract][Full Text] [Related]
19. Validity of a disposable end-tidal CO2 detector in verifying endotracheal tube placement in infants and children.
Bhende MS; Thompson AE; Cook DR; Saville AL
Ann Emerg Med; 1992 Feb; 21(2):142-5. PubMed ID: 1739199
[TBL] [Abstract][Full Text] [Related]
20. WITHDRAWN: Techniques to ascertain correct endotracheal tube placement in neonates.
Schmölzer GM; Roehr CCC
Cochrane Database Syst Rev; 2018 Jul; 7(7):CD010221. PubMed ID: 29975802
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]