BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

359 related articles for article (PubMed ID: 31792589)

  • 1. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tract embolization with gelatin sponge slurry for prevention of pneumothorax after percutaneous computed tomography-guided lung biopsy.
    Tran AA; Brown SB; Rosenberg J; Hovsepian DM
    Cardiovasc Intervent Radiol; 2014 Dec; 37(6):1546-53. PubMed ID: 24366313
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preventive tract embolization with gelatin sponge slurry is safe and considerably reduces pneumothorax after CT-guided lung biopsy with use of large 16-18 coaxial needles.
    Grange R; Sarkissian R; Bayle-Bleuez S; Tissot C; Tiffet O; Barral FG; Flaus A; Grange S
    Br J Radiol; 2022 May; 95(1133):20210869. PubMed ID: 34986006
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of Tract Embolization After Percutaneous Pulmonary Radiofrequency Ablation.
    Dassa M; Izaaryene J; Daidj N; Piana G
    Cardiovasc Intervent Radiol; 2021 Jun; 44(6):903-910. PubMed ID: 33492452
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.
    Kuban JD; Tam AL; Huang SY; Ensor JE; Philip AS; Chen GJ; Ahrar J; Murthy R; Avritscher R; Madoff DC; Mahvash A; Ahrar K; Wallace MJ; Nachiappan AC; Gupta S
    Cardiovasc Intervent Radiol; 2015 Dec; 38(6):1595-602. PubMed ID: 25920917
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Utilization of the track embolization technique to improve the safety of percutaneous lung biopsy and/or fiducial marker placement.
    Baadh AS; Hoffmann JC; Fadl A; Danda D; Bhat VR; Georgiou N; Hon M
    Clin Imaging; 2016; 40(5):1023-8. PubMed ID: 27348058
    [TBL] [Abstract][Full Text] [Related]  

  • 7. CT-guided Lung Biopsy: Effect of Biopsy-side Down Position on Pneumothorax and Chest Tube Placement.
    Drumm O; Joyce EA; de Blacam C; Gleeson T; Kavanagh J; McCarthy E; McDermott R; Beddy P
    Radiology; 2019 Jul; 292(1):190-196. PubMed ID: 31084480
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of preventive tract embolization with standardized gelatin sponge slurry on chest tube placement rate after CT-guided lung biopsy: a propensity score analysis.
    Grange R; Di Bisceglie M; Habert P; Resseguier N; Sarkissian R; Ferre M; Dassa M; Grange S; Izaaryene J; Piana G
    Insights Imaging; 2023 Nov; 14(1):212. PubMed ID: 38015340
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of intraparenchymal blood patching on the rate of pneumothorax in patients undergoing percutaneous CT-guided core biopsy of the lung.
    Perl RM; Risse E; Hetzel J; Bösmüller H; Kloth C; Fritz J; Horger M
    Eur J Radiol; 2019 Jul; 116():14-20. PubMed ID: 31153555
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
    Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
    Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung.
    Nakamura M; Yoshizako T; Koyama S; Kitagaki H
    J Med Imaging Radiat Oncol; 2011 Oct; 55(5):474-8. PubMed ID: 22008165
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors.
    Laurent F; Michel P; Latrabe V; Tunon de Lara M; Marthan R
    AJR Am J Roentgenol; 1999 Apr; 172(4):1049-53. PubMed ID: 10587145
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pneumothorax after computed tomography-guided lung biopsy: Utility of immediate post-procedure computed tomography and one-hour delayed chest radiography.
    Weinand JT; du Pisanie L; Ngeve S; Commander C; Yu H
    PLoS One; 2023; 18(4):e0284145. PubMed ID: 37075048
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.
    Ahrar JU; Gupta S; Ensor JE; Mahvash A; Sabir SH; Steele JR; McRae SE; Avritscher R; Huang SY; Odisio BC; Murthy R; Ahrar K; Wallace MJ; Tam AL
    Cardiovasc Intervent Radiol; 2017 Feb; 40(2):270-276. PubMed ID: 27826786
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.
    Nour-Eldin NE; Alsubhi M; Emam A; Lehnert T; Beeres M; Jacobi V; Gruber-Rouh T; Scholtz JE; Vogl TJ; Naguib NN
    Cardiovasc Intervent Radiol; 2016 Feb; 39(2):261-70. PubMed ID: 26148648
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gelfoam slurry tract occlusion after computed tomography-guided percutaneous lung biopsy: Does it prevent major pneumothorax?
    Sum R; Lau T; Paul E; Lau K
    J Med Imaging Radiat Oncol; 2021 Oct; 65(6):678-685. PubMed ID: 34121343
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Usual Interstitial Pneumonia: Associations With Complications After Percutaneous Transthoracic Needle Lung Biopsy.
    Park J; Lee JH; Hong W; Hwang EJ; Yoon SH; Goo JM; Park CM
    AJR Am J Roentgenol; 2024 Feb; 222(2):e2329938. PubMed ID: 37910039
    [No Abstract]   [Full Text] [Related]  

  • 18. Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period.
    Hiraki T; Mimura H; Gobara H; Shibamoto K; Inoue D; Matsui Y; Kanazawa S
    AJR Am J Roentgenol; 2010 Mar; 194(3):809-14. PubMed ID: 20173164
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of quantitative pulmonary emphysema score on the rate of pneumothorax and chest tube insertion in CT-guided lung biopsies.
    Theilig D; Petschelt D; Mayerhofer A; Hamm B; Gebauer B; Geisel D
    Sci Rep; 2020 Jul; 10(1):10978. PubMed ID: 32620852
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulmonary Intraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications following Percutaneous CT-Guided Needle Biopsy.
    Graffy P; Loomis SB; Pickhardt PJ; Lubner MG; Kitchin DR; Lee FT; Hinshaw JL
    J Vasc Interv Radiol; 2017 Apr; 28(4):608-613.e1. PubMed ID: 28185770
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.