124 related articles for article (PubMed ID: 31796249)
1. Multifunctional isotopic standards based steroidomics strategy: Exploration of cancer screening model.
Zhang Q; Liu R; Xu H; Yang X; Zhang Y; Wang Q; Gao P; Bi K; Han T; Li Q
J Chromatogr A; 2020 Mar; 1614():460723. PubMed ID: 31796249
[TBL] [Abstract][Full Text] [Related]
2. "Modeling-Prediction" Strategy for Deep Profiling of Lysophosphatidic Acids by Liquid Chromatography-Mass Spectrometry: Exploration Biomarkers of Breast Cancer.
Zhang Q; Yang X; Wang Q; Zhang Y; Gao P; Li Z; Liu R; Xu H; Bi K; Li Q
J Chromatogr A; 2020 Dec; 1634():461634. PubMed ID: 33176220
[TBL] [Abstract][Full Text] [Related]
3. A Novel Strategy for Targeted Lipidomics Based on LC-Tandem-MS Parameters Prediction, Quantification, and Multiple Statistical Data Mining: Evaluation of Lysophosphatidylcholines as Potential Cancer Biomarkers.
Zhang Q; Xu H; Liu R; Gao P; Yang X; Jin W; Zhang Y; Bi K; Li Q
Anal Chem; 2019 Mar; 91(5):3389-3396. PubMed ID: 30689358
[TBL] [Abstract][Full Text] [Related]
4. Highly Sensitive Quantification Method for Amine Submetabolome Based on AQC-Labeled-LC-Tandem-MS and Multiple Statistical Data Mining: A Potential Cancer Screening Approach.
Zhang Q; Xu H; Liu R; Gao P; Yang X; Li P; Wang X; Zhang Y; Bi K; Li Q
Anal Chem; 2018 Oct; 90(20):11941-11948. PubMed ID: 30208276
[TBL] [Abstract][Full Text] [Related]
5. Isotope Inversion Experiment evaluating the suitability of calibration in surrogate matrix for quantification via LC-MS/MS-Exemplary application for a steroid multi-method.
Suhr AC; Vogeser M; Grimm SH
J Pharm Biomed Anal; 2016 May; 124():309-318. PubMed ID: 26974483
[TBL] [Abstract][Full Text] [Related]
6. Across-polarity quantification method for broad metabolome coverage based on consecutive nanoconfined liquid phase nanoextraction technology: Application in discovering the plasma potential biomarkers of different types of cancer.
Yu C; Zhang Q; Zou Y; Liu R; Zhao J; Bi K; Li D; Li Q
Anal Chim Acta; 2021 Jul; 1167():338577. PubMed ID: 34049631
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of steroidomics by liquid chromatography hyphenated to mass spectrometry as a powerful analytical strategy for measuring human steroid perturbations.
Jeanneret F; Tonoli D; Rossier MF; Saugy M; Boccard J; Rudaz S
J Chromatogr A; 2016 Jan; 1430():97-112. PubMed ID: 26195035
[TBL] [Abstract][Full Text] [Related]
8. From a single steroid to the steroidome: Trends and analytical challenges.
Olesti E; Boccard J; Visconti G; González-Ruiz V; Rudaz S
J Steroid Biochem Mol Biol; 2021 Feb; 206():105797. PubMed ID: 33259940
[TBL] [Abstract][Full Text] [Related]
9. Multiplexed MRM-Based Protein Quantitation Using Two Different Stable Isotope-Labeled Peptide Isotopologues for Calibration.
LeBlanc A; Michaud SA; Percy AJ; Hardie DB; Yang J; Sinclair NJ; Proudfoot JI; Pistawka A; Smith DS; Borchers CH
J Proteome Res; 2017 Jul; 16(7):2527-2536. PubMed ID: 28516774
[TBL] [Abstract][Full Text] [Related]
10. Comparison of a stable isotope labeled (SIL) peptide and an extended SIL peptide as internal standards to track digestion variability of an unstable signature peptide during quantification of a cancer biomarker, human osteopontin, from plasma using capillary microflow LC-MS/MS.
Faria M; Halquist MS; Yuan M; Mylott W; Jenkins RG; Karnes HT
J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Sep; 1001():156-68. PubMed ID: 26279007
[TBL] [Abstract][Full Text] [Related]
11. Stable isotope N-phosphoryl amino acids labeling for quantitative profiling of amine-containing metabolites using liquid chromatography mass spectrometry.
Zhang S; Shi J; Shan C; Huang C; Wu Y; Ding R; Xue Y; Liu W; Zhou Q; Zhao Y; Xu P; Gao X
Anal Chim Acta; 2017 Jul; 978():24-34. PubMed ID: 28595723
[TBL] [Abstract][Full Text] [Related]
12. Comprehensive lipidomics of mouse plasma using class-specific surrogate calibrants and SWATH acquisition for large-scale lipid quantification in untargeted analysis.
Drotleff B; Illison J; Schlotterbeck J; Lukowski R; Lämmerhofer M
Anal Chim Acta; 2019 Dec; 1086():90-102. PubMed ID: 31561798
[TBL] [Abstract][Full Text] [Related]
13. Steroid profile analysis by LC-HRMS in human seminal fluid.
Olesti E; Garcia A; Rahban R; Rossier MF; Boccard J; Nef S; González-Ruiz V; Rudaz S
J Chromatogr B Analyt Technol Biomed Life Sci; 2020 Jan; 1136():121929. PubMed ID: 31841978
[TBL] [Abstract][Full Text] [Related]
14. Matrix effect management in liquid chromatography mass spectrometry: the internal standard normalized matrix effect.
De Nicolò A; Cantù M; D'Avolio A
Bioanalysis; 2017 Jul; 9(14):1093-1105. PubMed ID: 28737421
[TBL] [Abstract][Full Text] [Related]
15. UHPLC-HRMS Analysis for Steroid Profiling in Serum (Steroidomics).
Ponzetto F; Boccard J; Nicoli R; Kuuranne T; Saugy M; Rudaz S
Methods Mol Biol; 2018; 1738():261-278. PubMed ID: 29654596
[TBL] [Abstract][Full Text] [Related]
16. Surrogate matrix and surrogate analyte approaches for definitive quantitation of endogenous biomolecules.
Jones BR; Schultz GA; Eckstein JA; Ackermann BL
Bioanalysis; 2012 Oct; 4(19):2343-56. PubMed ID: 23088461
[TBL] [Abstract][Full Text] [Related]
17. Quantification of endogenous steroids in human urine by gas chromatography mass spectrometry using a surrogate analyte approach.
Ahmadkhaniha R; Shafiee A; Rastkari N; Khoshayand MR; Kobarfard F
J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Apr; 878(11-12):845-52. PubMed ID: 20189891
[TBL] [Abstract][Full Text] [Related]
18. Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard.
Jemal M; Schuster A; Whigan DB
Rapid Commun Mass Spectrom; 2003; 17(15):1723-34. PubMed ID: 12872277
[TBL] [Abstract][Full Text] [Related]
19. Validation of a multiplexed LC-MS/MS clinical assay to quantify insulin-like growth factor-binding proteins in human serum and its application in a clinical study.
Liu N; Tengstrand E; Boernsen KO; Bek S; Hsieh F
Toxicol Appl Pharmacol; 2019 May; 371():74-83. PubMed ID: 30926377
[TBL] [Abstract][Full Text] [Related]
20. Stable isotope labeling - dispersive solid phase extraction - liquid chromatography - tandem mass spectrometry for quantitative analysis of transsulfuration pathway thiols in human serum.
Wang YL; Zhu QF; Cheng LM; Wang ST; Qin SS; Zheng SJ; Xiao HM; Li JJ; Liu SM; Yuan BF; Feng YQ
J Chromatogr B Analyt Technol Biomed Life Sci; 2018 Apr; 1083():12-19. PubMed ID: 29518632
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]