These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
599 related articles for article (PubMed ID: 31797062)
1. Carbon nanotube hollow polyhedrons derived from ZIF-8@ZIF-67 coupled to electro-deposited gold nanoparticles for voltammetric determination of acetaminophen. Jin Y; Li X; Ge C; Ma J; Li Y; Zhao E; Yao S; Xu G; Li D Mikrochim Acta; 2019 Dec; 187(1):6. PubMed ID: 31797062 [TBL] [Abstract][Full Text] [Related]
2. Au-Co nanoparticles-embedded N-doped carbon nanotube hollow polyhedron modified electrode for electrochemical determination of quercetin. Luo G; Deng Y; Zhu L; Liu J; Zhang B; Zhang Y; Sun W; Li G Mikrochim Acta; 2020 Sep; 187(10):546. PubMed ID: 32886168 [TBL] [Abstract][Full Text] [Related]
3. An electrochemical sensor based on electro-polymerization of caffeic acid and Zn/Ni-ZIF-8-800 on glassy carbon electrode for the sensitive detection of acetaminophen. Zhang W; Zong L; Liu S; Pei S; Zhang Y; Ding X; Jiang B; Zhang Y Biosens Bioelectron; 2019 Apr; 131():200-206. PubMed ID: 30844596 [TBL] [Abstract][Full Text] [Related]
4. Nitrogen-rich core-shell structured particles consisting of carbonized zeolitic imidazolate frameworks and reduced graphene oxide for amperometric determination of hydrogen peroxide. Li Z; Jiang Y; Wang Z; Wang W; Yuan Y; Wu X; Liu X; Li M; Dilpazir S; Zhang G; Wang D; Liu C; Jiang J Mikrochim Acta; 2018 Oct; 185(11):501. PubMed ID: 30302565 [TBL] [Abstract][Full Text] [Related]
5. A metal-free and preconcentration-free method for non-enzymatic amperometric determination of pentachlorophenol using a ZIF-derived hollow carbon material. Zhu X; Zhao H; Shen J; Chen H; Cai X; Xu J; Wang X; Wang L; Lan M Mikrochim Acta; 2020 Mar; 187(4):224. PubMed ID: 32170431 [TBL] [Abstract][Full Text] [Related]
6. Electrochemical determination of dopamine and uric acid using a glassy carbon electrode modified with a composite consisting of a Co(II)-based metalorganic framework (ZIF-67) and graphene oxide. Tang J; Jiang S; Liu Y; Zheng S; Bai L; Guo J; Wang J Mikrochim Acta; 2018 Oct; 185(10):486. PubMed ID: 30276484 [TBL] [Abstract][Full Text] [Related]
7. One-step electrodeposition of graphene loaded nickel oxides nanoparticles for acetaminophen detection. Liu GT; Chen HF; Lin GM; Ye PP; Wang XP; Jiao YZ; Guo XY; Wen Y; Yang HF Biosens Bioelectron; 2014 Jun; 56():26-32. PubMed ID: 24462827 [TBL] [Abstract][Full Text] [Related]
8. Core-Shell ZIF-8@ZIF-67-Derived CoP Nanoparticle-Embedded N-Doped Carbon Nanotube Hollow Polyhedron for Efficient Overall Water Splitting. Pan Y; Sun K; Liu S; Cao X; Wu K; Cheong WC; Chen Z; Wang Y; Li Y; Liu Y; Wang D; Peng Q; Chen C; Li Y J Am Chem Soc; 2018 Feb; 140(7):2610-2618. PubMed ID: 29341596 [TBL] [Abstract][Full Text] [Related]
9. Nitrogen-doped carbon dodecahedron embedded with cobalt nanoparticles for the direct electro-oxidation of glucose and efficient nonenzymatic glucose sensing. Mo G; Zheng X; Ye N; Ruan Z Talanta; 2021 Apr; 225():121954. PubMed ID: 33592709 [TBL] [Abstract][Full Text] [Related]
10. Preparation of reduced graphite oxide loaded with cobalt(II) and nitrogen co-doped carbon polyhedrons from a metal-organic framework (type ZIF-67), and its application to electrochemical determination of metronidazole. Chen H; Wu X; Zhao R; Zheng Z; Yuan Q; Dong Z; Gan W Mikrochim Acta; 2019 Aug; 186(9):623. PubMed ID: 31414250 [TBL] [Abstract][Full Text] [Related]
11. A composite material based on nanoparticles of yttrium (III) oxide for the selective and sensitive electrochemical determination of acetaminophen. Baytak AK; Teker T; Duzmen S; Aslanoglu M Mater Sci Eng C Mater Biol Appl; 2016 Sep; 66():278-284. PubMed ID: 27207064 [TBL] [Abstract][Full Text] [Related]
12. Ultra-sensitive film sensor based on Al2O3-Au nanoparticles supported on PDDA-functionalized graphene for the determination of acetaminophen. Li J; Sun W; Wang X; Duan H; Wang Y; Sun Y; Ding C; Luo C Anal Bioanal Chem; 2016 Aug; 408(20):5567-76. PubMed ID: 27255103 [TBL] [Abstract][Full Text] [Related]
13. Electropolymerized surface ion imprinting films on a gold nanoparticles/single-wall carbon nanotube nanohybrids modified glassy carbon electrode for electrochemical detection of trace mercury(II) in water. Fu XC; Wu J; Nie L; Xie CG; Liu JH; Huang XJ Anal Chim Acta; 2012 Mar; 720():29-37. PubMed ID: 22365117 [TBL] [Abstract][Full Text] [Related]
14. Magnetic molecularly imprinting polymers, reduced graphene oxide, and zeolitic imidazolate frameworks modified electrochemical sensor for the selective and sensitive detection of catechin. Fu Y; You Z; Xiao A; Liu L Mikrochim Acta; 2021 Feb; 188(3):71. PubMed ID: 33547976 [TBL] [Abstract][Full Text] [Related]
15. Electrochemical immunoassay for the carcinoembryonic antigen based on Au NPs modified zeolitic imidazolate framework and ordered mesoporous carbon. Zhang Y; Zhang Z; Rong S; Yu H; Gao H; Ding P; Chang D; Pan H Mikrochim Acta; 2020 Apr; 187(5):264. PubMed ID: 32270338 [TBL] [Abstract][Full Text] [Related]
16. Rapid synthesis of a hybrid of rGO/AuNPs/MWCNTs for sensitive sensing of 4-aminophenol and acetaminophen simultaneously. Dou N; Qu J Anal Bioanal Chem; 2021 Jan; 413(3):813-820. PubMed ID: 32783127 [TBL] [Abstract][Full Text] [Related]
17. Ketjen black/ferrocene dual-doped MOFs and aptamer-coupling gold nanoparticles used as a novel ratiometric electrochemical aptasensor for vanillin detection. Sun Y; Jiang X; Jin H; Gui R Anal Chim Acta; 2019 Nov; 1083():101-109. PubMed ID: 31493800 [TBL] [Abstract][Full Text] [Related]
18. A hybrid material composed of reduced graphene oxide and porous carbon prepared by carbonization of a zeolitic imidazolate framework (type ZIF-8) for voltammetric determination of chloramphenicol. Yuan Y; Xu X; Xia J; Zhang F; Wang Z; Liu Q Mikrochim Acta; 2019 Feb; 186(3):191. PubMed ID: 30778741 [TBL] [Abstract][Full Text] [Related]
19. An electrochemical daunorubicin sensor based on the use of platinum nanoparticles loaded onto a nanocomposite prepared from nitrogen decorated reduced graphene oxide and single-walled carbon nanotubes. Kong FY; Li RF; Yao L; Wang ZX; Lv WX; Wang W Mikrochim Acta; 2019 May; 186(5):321. PubMed ID: 31049702 [TBL] [Abstract][Full Text] [Related]
20. A glassy carbon electrode modified with a composite consisting of gold nanoparticle, reduced graphene oxide and poly(L-arginine) for simultaneous voltammetric determination of dopamine, serotonin and L-tryptophan. Khan MZH; Liu X; Tang Y; Zhu J; Hu W; Liu X Mikrochim Acta; 2018 Aug; 185(9):439. PubMed ID: 30167981 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]