833 related articles for article (PubMed ID: 31799753)
1. A daily end-to-end quality assurance workflow for MR-guided online adaptive radiation therapy on MR-Linac.
Chen X; Ahunbay E; Paulson ES; Chen G; Li XA
J Appl Clin Med Phys; 2020 Jan; 21(1):205-212. PubMed ID: 31799753
[TBL] [Abstract][Full Text] [Related]
2. Technical Note: Development and performance of a software tool for quality assurance of online replanning with a conventional Linac or MR-Linac.
Chen GP; Ahunbay E; Li XA
Med Phys; 2016 Apr; 43(4):1713. PubMed ID: 27036569
[TBL] [Abstract][Full Text] [Related]
3. MR-linac daily semi-automated end-to-end quality control verification.
Malkov VN; Winter JD; Mateescu D; Létourneau D
J Appl Clin Med Phys; 2023 May; 24(5):e13916. PubMed ID: 36763085
[TBL] [Abstract][Full Text] [Related]
4. Characterization and longitudinal assessment of daily quality assurance for an MR-guided radiotherapy (MRgRT) linac.
Mittauer KE; Dunkerley DAP; Yadav P; Bayouth JE
J Appl Clin Med Phys; 2019 Nov; 20(11):27-36. PubMed ID: 31633882
[TBL] [Abstract][Full Text] [Related]
5. Real-time motion-including dose estimation of simulated multi-leaf collimator-tracked magnetic resonance-guided radiotherapy.
Persson E; Goodwin E; Eiben B; Wetscherek A; Nill S; Oelfke U
Med Phys; 2024 Mar; 51(3):2221-2229. PubMed ID: 37898109
[TBL] [Abstract][Full Text] [Related]
6. Characterization of positional accuracy of a double-focused and double-stack multileaf collimator on an MR-guided radiotherapy (MRgRT) Linac using an IC-profiler array.
Mittauer KE; Yadav P; Paliwal B; Bayouth JE
Med Phys; 2020 Feb; 47(2):317-330. PubMed ID: 31682018
[TBL] [Abstract][Full Text] [Related]
7. A virtual phantom for patient-specific QA On A 1.5T MR-linac.
Ji M; Li Z; Tian Y; Zhang K; Li M; Chen Y
J Appl Clin Med Phys; 2024 May; 25(5):e14264. PubMed ID: 38252813
[TBL] [Abstract][Full Text] [Related]
8. Measurement validation of treatment planning for a MR-Linac.
Chen X; Paulson ES; Ahunbay E; Sanli A; Klawikowski S; Li XA
J Appl Clin Med Phys; 2019 Jul; 20(7):28-38. PubMed ID: 31254376
[TBL] [Abstract][Full Text] [Related]
9. Feasibility of a GATE Monte Carlo platform in a clinical pretreatment QA system for VMAT treatment plans using TrueBeam with an HD120 multileaf collimator.
Lee B; Jeong S; Chung K; Yoon M; Park HC; Han Y; Jung SH
J Appl Clin Med Phys; 2019 Oct; 20(10):101-110. PubMed ID: 31544350
[TBL] [Abstract][Full Text] [Related]
10. Quality assurance of IMRT treatment plans for a 1.5 T MR-linac using a 2D ionization chamber array and a static solid phantom.
Mönnich D; Winter J; Nachbar M; Künzel L; Boeke S; Gani C; Dohm O; Zips D; Thorwarth D
Phys Med Biol; 2020 Aug; 65(16):16NT01. PubMed ID: 32663819
[TBL] [Abstract][Full Text] [Related]
11. Quality assurance for on-table adaptive magnetic resonance guided radiation therapy: A software tool to complement secondary dose calculation and failure modes discovered in clinical routine.
Rippke C; Schrenk O; Renkamp CK; Buchele C; Hörner-Rieber J; Debus J; Alber M; Klüter S
J Appl Clin Med Phys; 2022 Mar; 23(3):e13523. PubMed ID: 35019212
[TBL] [Abstract][Full Text] [Related]
12. Assessment of image quality and dose calculation accuracy on kV CBCT, MV CBCT, and MV CT images for urgent palliative radiotherapy treatments.
Held M; Cremers F; Sneed PK; Braunstein S; Fogh SE; Nakamura J; Barani I; Perez-Andujar A; Pouliot J; Morin O
J Appl Clin Med Phys; 2016 Mar; 17(2):279-290. PubMed ID: 27074487
[TBL] [Abstract][Full Text] [Related]
13. A method to reconstruct and apply 3D primary fluence for treatment delivery verification.
Liu S; Mazur TR; Li H; Curcuru A; Green OL; Sun B; Mutic S; Yang D
J Appl Clin Med Phys; 2017 Jan; 18(1):128-138. PubMed ID: 28291913
[TBL] [Abstract][Full Text] [Related]
14. Technical Note: End-to-end verification of an MR-Linac using a dynamic motion phantom.
Liu X; Li C; Zhu J; Gong G; Sun H; Li X; Sun M; Zhang Z; Li B; Yin Y; Li Z
Med Phys; 2021 Sep; 48(9):5479-5489. PubMed ID: 34174099
[TBL] [Abstract][Full Text] [Related]
15. End-to-end validation of the geometric dose delivery performance of MR linac adaptive radiotherapy.
Bernchou U; Christiansen RL; Bertelsen A; Tilly D; Riis HL; Jensen HR; Mahmood F; Hansen CR; Hansen VN; Schytte T; Brink C
Phys Med Biol; 2021 Feb; 66(4):045034. PubMed ID: 33321475
[TBL] [Abstract][Full Text] [Related]
16. Development and clinical application of a GPU-based Monte Carlo dose verification module and software for 1.5 T MR-LINAC.
Cheng B; Xu Y; Li S; Ren Q; Pei X; Men K; Dai J; Xu XG
Med Phys; 2023 May; 50(5):3172-3183. PubMed ID: 36862110
[TBL] [Abstract][Full Text] [Related]
17. Dosimetric performance of the Elekta Unity MR-linac system: 2D and 3D dosimetry in anthropomorphic inhomogeneous geometry.
Pappas E; Kalaitzakis G; Boursianis T; Zoros E; Zourari K; Pappas EP; Makris D; Seimenis I; Efstathopoulos E; Maris TG
Phys Med Biol; 2019 Nov; 64(22):225009. PubMed ID: 31665709
[TBL] [Abstract][Full Text] [Related]
18. The Quality Assurance of a 1.5 T MR-Linac.
Riis HL; Chick J; Dunlop A; Tilly D
Semin Radiat Oncol; 2024 Jan; 34(1):120-128. PubMed ID: 38105086
[TBL] [Abstract][Full Text] [Related]
19. Longitudinal assessment of quality assurance measurements in a 1.5T MR-linac: Part I-Linear accelerator.
Subashi E; Lim SB; Gonzalez X; Tyagi N
J Appl Clin Med Phys; 2021 Oct; 22(10):190-201. PubMed ID: 34505349
[TBL] [Abstract][Full Text] [Related]
20. Commissioning of a 1.5T Elekta Unity MR-linac: A single institution experience.
Snyder JE; St-Aubin J; Yaddanapudi S; Boczkowski A; Dunkerley DAP; Graves SA; Hyer DE
J Appl Clin Med Phys; 2020 Jul; 21(7):160-172. PubMed ID: 32432405
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]