  • 1. Failure mechanisms of metal-backed patellar components.
    Stulberg SD; Stulberg BN; Hamati Y; Tsao A
    Clin Orthop Relat Res; 1988 Nov; (236):88-105. PubMed ID: 3180591
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Failure of the metal-backed patellar component after total knee replacement.
    Bayley JC; Scott RD; Ewald FC; Holmes GB
    J Bone Joint Surg Am; 1988 Jun; 70(5):668-74. PubMed ID: 3392059
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Isolated metal-backed patellar component revision following total knee arthroplasty.
    Chan WH; Yeo SJ; Lee BP; Tay BK; Tan SK
    Singapore Med J; 1998 Jul; 39(7):303-5. PubMed ID: 9885691
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Isolated revision of failed metal-backed patellar components: outcome with minimum 4-year follow-up.
    Burke WV; Ammeen DJ; Engh GA
    J Arthroplasty; 2005 Dec; 20(8):998-1001. PubMed ID: 16376254
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Further observations on metal-backed patellar component failure.
    Bayley JC; Scott RD
    Clin Orthop Relat Res; 1988 Nov; (236):82-7. PubMed ID: 3180590
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces.
    Feng EL; Stulberg SD; Wixson RL
    Clin Orthop Relat Res; 1994 Feb; (299):60-71. PubMed ID: 8119038
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Retention of superficially damaged femoral components after metal-backed patella component failure.
    Garcia RM; Kraay MJ; Goldberg VM
    J Arthroplasty; 2008 Sep; 23(6):850-8. PubMed ID: 18534531
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of metal-backed patellar prostheses in total knee arthroplasty.
    Laskin RS; Bucknell A
    Clin Orthop Relat Res; 1990 Nov; (260):52-5. PubMed ID: 2225642
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Polyethylene failure of metal-backed patellar components. 111 AGC total knees followed for 7-22 months.
    Andersen HN; Ernst C; Frandsen PA
    Acta Orthop Scand; 1991 Feb; 62(1):1-3. PubMed ID: 2003379
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A metal-backed, rotating-bearing patellar prosthesis to lower contact stress. An 11-year clinical study.
    Buechel FF; Rosa RA; Pappas MJ
    Clin Orthop Relat Res; 1989 Nov; (248):34-49. PubMed ID: 2805494
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Isolated all-polyethylene patellar revisions for metal-backed patellar failure.
    Garcia RM; Kraay MJ; Goldberg VM
    Clin Orthop Relat Res; 2008 Nov; 466(11):2784-9. PubMed ID: 18688690
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patellar component failure in cementless total knee arthroplasty.
    Rosenberg AG; Andriacchi TP; Barden R; Galante JO
    Clin Orthop Relat Res; 1988 Nov; (236):106-14. PubMed ID: 3180561
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Total knee replacement: radiologic findings in failure of porous-coated metal-backed patellar component.
    Piraino D; Richmond B; Freed H; Belhobek G; Schils J; Stulberg B
    AJR Am J Roentgenol; 1990 Sep; 155(3):555-8. PubMed ID: 2117356
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Patellar tilt and subluxation in total knee arthroplasty. Relationship to pain, fixation, and design.
    Bindelglass DF; Cohen JL; Dorr LD
    Clin Orthop Relat Res; 1993 Jan; (286):103-9. PubMed ID: 8425330
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Midterm results in metal-backed patella revisions for metallosis.
    Arredondo J; Worland RL; Jessup DE; Angles F
    Am J Orthop (Belle Mead NJ); 1997 Sep; 26(9):598-600. PubMed ID: 9316720
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Press-fit metal-backed rotating patella: seven- to 14-year followup.
    Hartford JM; Herfel C; Kaufer H
    Clin Orthop Relat Res; 2002 Oct; (403):153-60. PubMed ID: 12360021
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Isolated patellar revisions for failed metal-backed components: 2- to 9-year follow-up.
    Koh JS; Yeo SJ; Lo NN; Tan SK; Tay BK; Seow KH
    J Arthroplasty; 2004 Oct; 19(7):880-6. PubMed ID: 15483805
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The clinical and roentgenographic results of cementless porous-coated patellar fixation.
    Firestone TP; Teeny SM; Krackow KA; Hungerford DS
    Clin Orthop Relat Res; 1991 Dec; (273):184-9. PubMed ID: 1959269
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fracture/dissociation of the polyethylene in metal-backed patellar components in total knee arthroplasty.
    Lombardi AV; Engh GA; Volz RG; Albrigo JL; Brainard BJ
    J Bone Joint Surg Am; 1988 Jun; 70(5):675-9. PubMed ID: 3392060
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Metal-Backed Patella Implants in Knee Arthroplasty: Can the Past Predict the Future?
    Gustke KA; Simon P; Meheux CJ
    J Arthroplasty; 2023 Jun; 38(6S):S131-S136. PubMed ID: 36791886
    [TBL] [Abstract][Full Text] [Related]  