These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 31806245)

  • 1. Evaluation of two chemiluminescent assays compared with radioimmunoassay for serum progesterone measurement in bitches.
    Tal S; Mazaki-Tovi M; Druker S; Novak S; Raz T; Aroch I
    Theriogenology; 2020 Apr; 147():116-123. PubMed ID: 31806245
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparing the values of progesterone in the blood of bitches as measured with a chemiluminescence immunoassay and a radioimmunoassay.
    Nöthling JO; De Cramer KGM
    Reprod Domest Anim; 2018 Oct; 53(5):1136-1141. PubMed ID: 29938844
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Blood periovulatory progesterone quantification using different techniques in the dog.
    Gloria A; Contri A; Carluccio A; Robbe D
    Anim Reprod Sci; 2018 May; 192():179-184. PubMed ID: 29545003
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of a Chemiluminescent Immunoassay for Measurement of Equine Insulin.
    Carslake HB; Pinchbeck GL; McGowan CM
    J Vet Intern Med; 2017 Mar; 31(2):568-574. PubMed ID: 28124389
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of progesterone assay by chemiluminescence or radioimmunoassay for clinical decision-making in canine reproduction.
    Nöthling JO; De Cramer KGM
    J S Afr Vet Assoc; 2019 Oct; 90(0):e1-e6. PubMed ID: 31714111
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of the Immulite and RIA assay methods for measuring peripheral blood progesterone levels in Greyhound bitches.
    Chapwanya A; Clegg T; Stanley P; Vaughan L
    Theriogenology; 2008 Sep; 70(5):795-9. PubMed ID: 18579195
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Aldosterone determination: comparison of a RIA assay and a CLIA assay.
    Belaidi N; Georges A; Brossaud J; Corcuff JB
    Clin Biochem; 2015 Jan; 48(1-2):89-92. PubMed ID: 25445229
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of three different methods for the quantification of equine insulin.
    Warnken T; Huber K; Feige K
    BMC Vet Res; 2016 Sep; 12(1):196. PubMed ID: 27613127
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The optimal mating time in the bitch based on the progesterone concentration in peripheral blood. A comparison of reliability between three ELISA test kits and a 125-iodine radioimmunoassay].
    van Klaveren NJ; Kooistra HS; Dieleman SJ; van Lith HA; Schaefers-Okkens AC
    Tijdschr Diergeneeskd; 2001 Nov; 126(21):680-5. PubMed ID: 11723806
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of two methods for measurement of equine insulin.
    Banse HE; McCann J; Yang F; Wagg C; McFarlane D
    J Vet Diagn Invest; 2014 Jul; 26(4):527-530. PubMed ID: 24928598
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of a Point-of-Care Analyzer With a Chemiluminescent Immunoassay for Serum Progesterone Measurement in Breeding Management of the Bitch.
    Zuercher J; Boes KM; Balogh O; Helms AB; Cecere JT
    Front Vet Sci; 2021; 8():660923. PubMed ID: 34055950
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of a commercially available radioimmunoassay and enzyme immunoassay for the analysis of progesterone and estradiol and the comparison of two extraction efficiency methods.
    Skenandore CS; Pineda A; Bahr JM; Newell-Fugate AE; Cardoso FC
    Domest Anim Endocrinol; 2017 Jul; 60():61-66. PubMed ID: 28454055
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Free thyroxine concentrations by equilibrium dialysis and chemiluminescent immunoassays in 13 hypothyroid dogs positive for thyroglobulin antibody.
    Randolph JF; Lamb SV; Cheraskin JL; Schanbacher BJ; Salerno VJ; Mack KM; Scarlett JM; Place NJ
    J Vet Intern Med; 2015; 29(3):877-81. PubMed ID: 25858585
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of surface plasmon field-enhanced fluorescence spectroscopy for rapid measurement of progesterone concentration in bitches.
    Fontbonne A; Maenhoudt C; Thoumire S; Roos J; Niewiadomska Z; Robiteau G; Rousselière E; Buronfosse T
    Am J Vet Res; 2021 May; 82(5):417-424. PubMed ID: 33904802
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variability in testosterone measurement between radioimmunoassay (RIA), chemiluminescence assay (CLIA) and liquid chromatography-tandem mass spectrometry (MS) among prostate cancer patients on androgen deprivation therapy (ADT).
    Tiwari R; Lajkosz K; Berjaoui M; Qaoud Y; Kenk M; Woffendin C; Caron P; Guillemette C; Fleshner N
    Urol Oncol; 2022 May; 40(5):193.e15-193.e20. PubMed ID: 35437219
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical and laboratory evaluation of specific chemiluminescence assays for intact and total proinsulin.
    Pfützner A; Kunt T; Langenfeld M; Löbig M; Knesovic M; Forst T
    Clin Chem Lab Med; 2003 Sep; 41(9):1234-8. PubMed ID: 14598875
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of radioimmunoassay and chemiluminescent assay methods to estimate canine blood cortisol concentrations.
    Russell NJ; Foster S; Clark P; Robertson ID; Lewis D; Irwin PJ
    Aust Vet J; 2007 Dec; 85(12):487-94. PubMed ID: 18042154
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of 2 enzyme immunoassays and a radioimmunoassay for measurement of progesterone concentrations in bovine plasma, skim milk, and whole milk.
    Colazo MG; Ambrose DJ; Kastelic JP; Small JA
    Can J Vet Res; 2008 Jan; 72(1):32-6. PubMed ID: 18214159
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effects of storage time and temperature and anticoagulant on laboratory measurements of canine blood progesterone concentrations.
    Volkmann DH
    Theriogenology; 2006 Oct; 66(6-7):1583-6. PubMed ID: 16480764
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical and financial evaluation of assays for progesterone in canine practice in the UK.
    Moxon R; Copley D; England GC
    Vet Rec; 2010 Oct; 167(14):528-31. PubMed ID: 21257399
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.