122 related articles for article (PubMed ID: 31808372)
1. Scattered Dose to Ovary From Radiotherapy for Neuroblastoma in Female Children.
Shen Y; Zhu C; Jiang M; Zhang S; Tu Y; Wang W; Zha Y
Technol Cancer Res Treat; 2019; 18():1533033819887985. PubMed ID: 31808372
[TBL] [Abstract][Full Text] [Related]
2. Scattered dose to gonads and associated risks from radiotherapy for common pediatric malignancies : a phantom study.
Mazonakis M; Zacharopoulou F; Kachris S; Varveris C; Damilakis J; Gourtsoyiannis N
Strahlenther Onkol; 2007 Jun; 183(6):332-7. PubMed ID: 17520188
[TBL] [Abstract][Full Text] [Related]
3. Proton radiotherapy for high-risk pediatric neuroblastoma: early outcomes and dose comparison.
Hattangadi JA; Rombi B; Yock TI; Broussard G; Friedmann AM; Huang M; Chen YL; Lu HM; Kooy H; MacDonald SM
Int J Radiat Oncol Biol Phys; 2012 Jul; 83(3):1015-22. PubMed ID: 22138463
[TBL] [Abstract][Full Text] [Related]
4. Dose fall-off patterns with volumetric modulated arc therapy and three-dimensional conformal radiotherapy including the "organ at risk" effect. Experience of linear accelerator-based frameless radiosurgery from a single institution.
Munshi A; Sarkar B; Roy S; Ganesh T; Mohanti BK
Cancer Radiother; 2019 Apr; 23(2):138-146. PubMed ID: 30797691
[TBL] [Abstract][Full Text] [Related]
5. Dosimetric characteristics of 6 and 10MV unflattened photon beams.
Kragl G; af Wetterstedt S; Knäusl B; Lind M; McCavana P; Knöös T; McClean B; Georg D
Radiother Oncol; 2009 Oct; 93(1):141-6. PubMed ID: 19592123
[TBL] [Abstract][Full Text] [Related]
6. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses.
Kragl G; Baier F; Lutz S; Albrich D; Dalaryd M; Kroupa B; Wiezorek T; Knöös T; Georg D
Z Med Phys; 2011 May; 21(2):91-101. PubMed ID: 20888199
[TBL] [Abstract][Full Text] [Related]
7. Exposure Risks Among Children Undergoing Radiation Therapy: Considerations in the Era of Image Guided Radiation Therapy.
Hess CB; Thompson HM; Benedict SH; Seibert JA; Wong K; Vaughan AT; Chen AM
Int J Radiat Oncol Biol Phys; 2016 Apr; 94(5):978-92. PubMed ID: 27026304
[TBL] [Abstract][Full Text] [Related]
8. Impact of grid size on uniform scanning and IMPT plans in XiO treatment planning system for brain cancer.
Rana S; Zheng Y
J Appl Clin Med Phys; 2015 Sep; 16(5):447–456. PubMed ID: 26699310
[TBL] [Abstract][Full Text] [Related]
9. Dose Sculpting Intensity Modulated Radiation Therapy for Vertebral Body Sparing in Children With Neuroblastoma.
Ng LW; Wong KK; Ally Wu CL; Sposto R; Olch AJ
Int J Radiat Oncol Biol Phys; 2018 Jul; 101(3):550-557. PubMed ID: 29680256
[TBL] [Abstract][Full Text] [Related]
10. Dosimetric comparison of three-dimensional conformal proton radiotherapy, intensity-modulated proton therapy, and intensity-modulated radiotherapy for treatment of pediatric craniopharyngiomas.
Boehling NS; Grosshans DR; Bluett JB; Palmer MT; Song X; Amos RA; Sahoo N; Meyer JJ; Mahajan A; Woo SY
Int J Radiat Oncol Biol Phys; 2012 Feb; 82(2):643-52. PubMed ID: 21277111
[TBL] [Abstract][Full Text] [Related]
11. Ovarian transposition before radiotherapy in cervical cancer patients: functional outcome and the adequate dose constraint.
Yin L; Lu S; Zhu J; Zhang W; Ke G
Radiat Oncol; 2019 Jun; 14(1):100. PubMed ID: 31182114
[TBL] [Abstract][Full Text] [Related]
12. Evaluating out-of-field doses during radiotherapy of paediatric brain tumours using lead shielding and flattening-filter free beams.
Beierholm AR; Nygaard DE; Juhl EL; Hansen R; Hansen J
Phys Med; 2019 Apr; 60():1-6. PubMed ID: 31000068
[TBL] [Abstract][Full Text] [Related]
13. Abdominal cancer during early childhood: a dosimetric comparison of proton beams to standard and advanced photon radiotherapy.
Hillbrand M; Georg D; Gadner H; Pötter R; Dieckmann K
Radiother Oncol; 2008 Nov; 89(2):141-9. PubMed ID: 18692928
[TBL] [Abstract][Full Text] [Related]
14. A comparison of out-of-field dose and its constituent components for intensity-modulated radiation therapy versus conformal radiation therapy: implications for carcinogenesis.
Ruben JD; Lancaster CM; Jones P; Smith RL
Int J Radiat Oncol Biol Phys; 2011 Dec; 81(5):1458-64. PubMed ID: 20950947
[TBL] [Abstract][Full Text] [Related]
15. Potential for reduced radiation-induced toxicity using intensity-modulated arc therapy for whole-brain radiotherapy with hippocampal sparing.
Pokhrel D; Sood S; Lominska C; Kumar P; Badkul R; Jiang H; Wang F
J Appl Clin Med Phys; 2015 Sep; 16(5):131–141. PubMed ID: 26699321
[TBL] [Abstract][Full Text] [Related]
16. Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels.
Onal C; Arslan G; Dolek Y; Efe E
Med Dosim; 2016 Winter; 41(4):310-314. PubMed ID: 27623736
[TBL] [Abstract][Full Text] [Related]
17. Second cancer risk after radiation therapy of ependymoma using the flattening filter free irradiation mode of a linear accelerator.
Alvarez Moret J; Obermeier T; Pohl F; Loeschel R; Koelbl O; Dobler B
J Appl Clin Med Phys; 2018 Sep; 19(5):632-639. PubMed ID: 30125453
[TBL] [Abstract][Full Text] [Related]
18. Peripheral doses from pediatric IMRT.
Klein EE; Maserang B; Wood R; Mansur D
Med Phys; 2006 Jul; 33(7):2525-31. PubMed ID: 16898456
[TBL] [Abstract][Full Text] [Related]
19. Lowering whole-body radiation doses in pediatric intensity-modulated radiotherapy through the use of unflattened photon beams.
Cashmore J; Ramtohul M; Ford D
Int J Radiat Oncol Biol Phys; 2011 Jul; 80(4):1220-7. PubMed ID: 21167659
[TBL] [Abstract][Full Text] [Related]
20. Reliable Radiation Technique to Minimize Ovarian Dose During Radiation Prophylaxis of Heterotopic Ossification.
Mourad WF; Packianathan S; Yan W; Pishgou M; Ma JK; Shaaban SG; Marchan EM; He R; Mobit PN; Yang CC; Vijayakumar S
Anticancer Res; 2017 Dec; 37(12):6929-6935. PubMed ID: 29187475
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]