These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 31808504)

  • 21. Aortic Dissection After Previous Aortic Valve Replacement for Bicuspid Aortic Valve Disease.
    Girdauskas E; Rouman M; Disha K; Espinoza A; Misfeld M; Borger MA; Kuntze T
    J Am Coll Cardiol; 2015 Sep; 66(12):1409-11. PubMed ID: 26383730
    [No Abstract]   [Full Text] [Related]  

  • 22. Bicuspid aortic valve repair by complete conversion from "raphe'd" (type 1) to "symmetric" (type 0) morphology.
    Gleason TG
    J Thorac Cardiovasc Surg; 2014 Dec; 148(6):2862-8.e1-2. PubMed ID: 24930615
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Prognostic Implications of Raphe in Bicuspid Aortic Valve Anatomy.
    Kong WK; Delgado V; Poh KK; Regeer MV; Ng AC; McCormack L; Yeo TC; Shanks M; Parent S; Enache R; Popescu BA; Liang M; Yip JW; Ma LC; Kamperidis V; van Rosendael PJ; van der Velde ET; Ajmone Marsan N; Bax JJ
    JAMA Cardiol; 2017 Mar; 2(3):285-292. PubMed ID: 28052146
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The De Kerchove/El Khoury/Schäfers' classification: a contemporary repair-oriented categorization of bicuspid aortic valves.
    Jahanyar J; Said SM; Tsai PI
    Eur J Cardiothorac Surg; 2023 May; 63(5):. PubMed ID: 37099716
    [No Abstract]   [Full Text] [Related]  

  • 25. Bicuspid aortic valve sparing root replacement.
    Patel PM; Wei JW; McPherson L; Binongo J; Leshnower BG; Chen EP
    J Card Surg; 2021 Jan; 36(1):118-123. PubMed ID: 33225511
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Stage B Aortic Regurgitation in Bicuspid Aortic Valve: New Observations on Progression Rate and Predictors.
    Yang LT; Pellikka PA; Enriquez-Sarano M; Maalouf JF; Scott CG; Michelena HI
    JACC Cardiovasc Imaging; 2020 Jun; 13(6):1442-1445. PubMed ID: 32192931
    [No Abstract]   [Full Text] [Related]  

  • 27. Corroborative Autopsy Findings for Current Concerns After Implantation of Self-Expandable Transcatheter Heart Valve.
    Ninomiya K; Yahagi K; Asami M; Tanaka T; Tomii D; Tanaka J; Komiyama K; Yokozuka M; Miura S; Aoki J; Tanabe K
    JACC Cardiovasc Interv; 2020 Jan; 13(2):261-262. PubMed ID: 31883722
    [No Abstract]   [Full Text] [Related]  

  • 28. The echocardiographic evaluation of a bicuspid aortic valve: the effect of jet eccentricity and left ventricular outflow tract geometry on the effective orifice area.
    Naseem T; Song M; Ianchulev S; Rastegar H; Cobey FC
    J Cardiothorac Vasc Anesth; 2014 Apr; 28(2):423-7. PubMed ID: 24485562
    [No Abstract]   [Full Text] [Related]  

  • 29. Isolated bicuspid aortic valve repair with double annuloplasty: The French approach.
    Camporrotondo M; Manuel Clusa N; Angel Chiappe M; Mariano Vrancic J; Piccinini F; Navia D
    Multimed Man Cardiothorac Surg; 2020 May; 2020():. PubMed ID: 32436662
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Acute aortic regurgitation in a bicuspid aortic valve due to the rupture of an anomalous cord.
    Watanabe H; Shimbo M; Iino K; Yamamoto H; Ito H
    Anatol J Cardiol; 2017 Jun; 17(6):E5. PubMed ID: 28617301
    [No Abstract]   [Full Text] [Related]  

  • 31. Repair of regurgitant bicuspid aortic valves: a systematic approach.
    Boodhwani M; de Kerchove L; Glineur D; Rubay J; Vanoverschelde JL; Noirhomme P; El Khoury G
    J Thorac Cardiovasc Surg; 2010 Aug; 140(2):276-284.e1. PubMed ID: 20488466
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Quadricuspid aortic valve detected by three-dimensional transesophageal echocardiography.
    Kanda H; Kunisawa T; Iida T; Kanao M; Toyama Y; Iwasaki H
    J Cardiothorac Vasc Anesth; 2015; 29(3):e33-5. PubMed ID: 25847413
    [No Abstract]   [Full Text] [Related]  

  • 33. Aortic root destruction after aortic valvuloplasty for bicuspid aortic valve.
    Nakao M; Yoshitake M; Matsumura Y; Takagi T; Arimura S; Nagahori R; Bando K; Masuzawa A; Ono M; Kunihara T
    Gen Thorac Cardiovasc Surg; 2021 Feb; 69(2):350-352. PubMed ID: 32712754
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Transcatheter repair of aortic leaflet perforation in a patient with prior surgical bicuspid aortic valve repair.
    Lim W; Smith T; Rogers JH
    Catheter Cardiovasc Interv; 2015 Nov; 86(6):1136-40. PubMed ID: 25914034
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Aortic shear stress in patients with bicuspid aortic valve with stenosis and insufficiency.
    Shan Y; Li J; Wang Y; Wu B; Barker AJ; Markl M; Wang C; Wang X; Shu X
    J Thorac Cardiovasc Surg; 2017 Jun; 153(6):1263-1272.e1. PubMed ID: 28268004
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Modified reimplantation of bicuspid aortic valve.
    Jasinski M
    Multimed Man Cardiothorac Surg; 2018 Feb; 2018():. PubMed ID: 29485775
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Replacement of Regurgitant Bicuspid Aortic Valve in a Dilated, Non-Compacted Left Ventricle.
    Schenone AL; Cohen A; Pettersson G; Majdalany D
    World J Pediatr Congenit Heart Surg; 2016 May; 7(3):389-93. PubMed ID: 26701622
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Park's stitch for a bicuspid aortic valve in a patient on LVAD support.
    Maoz-Metzl D; Morsy M; Khalife WI; Lick SD
    J Card Surg; 2014 Nov; 29(6):843-5. PubMed ID: 25100071
    [TBL] [Abstract][Full Text] [Related]  

  • 39. TAVR for Stenotic Bicuspid Aortic Valve: Feasible, Continuously Improving Results With Another Red Flag.
    Radermecker MA; Sprynger M; Hans G
    J Am Coll Cardiol; 2020 Dec; 76(22):2591-2594. PubMed ID: 33243379
    [No Abstract]   [Full Text] [Related]  

  • 40. The surgical correction of aortic regurgitation; bicuspid conversion.
    BAILEY CP; ZIMMERMAN J
    Am J Cardiol; 1959 Jan; 3(1):6-21. PubMed ID: 13606059
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.