These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

261 related articles for article (PubMed ID: 31808855)

  • 1. Bleeding in critical care associated with left ventricular assist devices: pathophysiology, symptoms, and management.
    Leebeek FWG; Muslem R
    Hematology Am Soc Hematol Educ Program; 2019 Dec; 2019(1):88-96. PubMed ID: 31808855
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Acquired coagulopathy in patients with left ventricular assist devices.
    Muslem R; Caliskan K; Leebeek FWG
    J Thromb Haemost; 2018 Mar; 16(3):429-440. PubMed ID: 29274191
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Acquired von Willebrand syndrome in patients with a centrifugal or axial continuous flow left ventricular assist device.
    Meyer AL; Malehsa D; Budde U; Bara C; Haverich A; Strueber M
    JACC Heart Fail; 2014 Apr; 2(2):141-5. PubMed ID: 24720921
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anticoagulant treatment and bleeding complications in patients with left ventricular assist devices.
    den Exter PL; Beeres SLMA; Eikenboom J; Klok FA; Huisman MV
    Expert Rev Cardiovasc Ther; 2020 Jun; 18(6):363-372. PubMed ID: 32449431
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Understanding Left Ventricular Assist Devices.
    Aissaoui N; Jouan J; Gourjault M; Diebold B; Ortuno S; Hamdan A; Latremouille C; Pirracchio R; Morshuis M
    Blood Purif; 2018; 46(4):292-300. PubMed ID: 30048974
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.
    Birschmann I; Dittrich M; Eller T; Wiegmann B; Reininger AJ; Budde U; Strüber M
    J Heart Lung Transplant; 2014 Jan; 33(1):80-7. PubMed ID: 24418734
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bleeding with the artificial heart: Gastrointestinal hemorrhage in CF-LVAD patients.
    Gurvits GE; Fradkov E
    World J Gastroenterol; 2017 Jun; 23(22):3945-3953. PubMed ID: 28652649
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Survival of HeartMate II Patients Despite Cessation of Anticoagulation - Outcomes and Hemostatic Analysis.
    Zayat R; Khattab MA; Grottke O; Honickel M; Goetzenich A; Moza A; Stoppe C; Autschbach R; Tewarie L
    Circ J; 2018 Apr; 82(5):1309-1318. PubMed ID: 29237991
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Platelet dysfunction and acquired von Willebrand syndrome in patients with left ventricular assist devices.
    Baghai M; Heilmann C; Beyersdorf F; Nakamura L; Geisen U; Olschewski M; Zieger B
    Eur J Cardiothorac Surg; 2015 Sep; 48(3):421-7. PubMed ID: 25543177
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Acquired von Willebrand syndrome in continuous-flow ventricular assist device recipients.
    Crow S; Chen D; Milano C; Thomas W; Joyce L; Piacentino V; Sharma R; Wu J; Arepally G; Bowles D; Rogers J; Villamizar-Ortiz N
    Ann Thorac Surg; 2010 Oct; 90(4):1263-9; discussion 1269. PubMed ID: 20868825
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of anticoagulation and nonsurgical major bleeding in recipients of continuous-flow left ventricular assist devices.
    Veasey TM; Floroff CK; Strout SE; McElray KL; Brisco-Bacik MA; Cook JL; Toole JM; Craig ML; Van Bakel AB; Meadows HB; Uber WE
    Artif Organs; 2019 Aug; 43(8):736-744. PubMed ID: 30868618
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pre-operative risk factors of bleeding and stroke during left ventricular assist device support: an analysis of more than 900 HeartMate II outpatients.
    Boyle AJ; Jorde UP; Sun B; Park SJ; Milano CA; Frazier OH; Sundareswaran KS; Farrar DJ; Russell SD;
    J Am Coll Cardiol; 2014 Mar; 63(9):880-8. PubMed ID: 24316083
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Gastrointestinal Bleeding Following LVAD Placement from Top to Bottom.
    Cushing K; Kushnir V
    Dig Dis Sci; 2016 Jun; 61(6):1440-7. PubMed ID: 27017225
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gastrointestinal bleeding and subsequent risk of thromboembolic events during support with a left ventricular assist device.
    Stulak JM; Lee D; Haft JW; Romano MA; Cowger JA; Park SJ; Aaronson KD; Pagani FD
    J Heart Lung Transplant; 2014 Jan; 33(1):60-4. PubMed ID: 24021944
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Development of acquired von Willebrand syndrome during short-term micro axial pump support: implications for bleeding in a patient bridged to a long-term continuous-flow left ventricular assist device.
    Davis ME; Haglund NA; Tricarico NM; Keebler ME; Maltais S
    ASAIO J; 2014; 60(3):355-7. PubMed ID: 24614358
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Low-molecular-weight heparin for anti-coagulation after left ventricular assist device implantation.
    Sandner SE; Riebandt J; Haberl T; Mahr S; Rajek A; Schima H; Wieselthaler GM; Laufer G; Zimpfer D
    J Heart Lung Transplant; 2014 Jan; 33(1):88-93. PubMed ID: 24239003
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device.
    Meyer AL; Malehsa D; Bara C; Budde U; Slaughter MS; Haverich A; Strueber M
    Circ Heart Fail; 2010 Nov; 3(6):675-81. PubMed ID: 20739614
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of HeartWare ventricular assist device on the von Willebrand factor: results of an academic Belgian center.
    Esmaeilzadeh F; Wauters A; Wijns W; Argacha JF; van de Borne P
    BMC Cardiovasc Disord; 2016 Aug; 16(1):155. PubMed ID: 27485105
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy.
    Slaughter MS; Naka Y; John R; Boyle A; Conte JV; Russell SD; Aaronson KD; Sundareswaran KS; Farrar DJ; Pagani FD
    J Heart Lung Transplant; 2010 Jun; 29(6):616-24. PubMed ID: 20400335
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices.
    Suarez J; Patel CB; Felker GM; Becker R; Hernandez AF; Rogers JG
    Circ Heart Fail; 2011 Nov; 4(6):779-84. PubMed ID: 22086831
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.