These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

189 related articles for article (PubMed ID: 31811490)

  • 1. Comparison of multi-delay FAIR and pCASL labeling approaches for renal perfusion quantification at 3T MRI.
    Harteveld AA; de Boer A; Franklin SL; Leiner T; van Stralen M; Bos C
    MAGMA; 2020 Feb; 33(1):81-94. PubMed ID: 31811490
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurement of arterial transit time and renal blood flow using pseudocontinuous ASL MRI with multiple post-labeling delays: Feasibility, reproducibility, and variation.
    Kim DW; Shim WH; Yoon SK; Oh JY; Kim JK; Jung H; Matsuda T; Kim D
    J Magn Reson Imaging; 2017 Sep; 46(3):813-819. PubMed ID: 28092411
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pancreatic perfusion and arterial-transit-time quantification using pseudocontinuous arterial spin labeling at 3T.
    Taso M; Guidon A; Zhao L; Mortele KJ; Alsop DC
    Magn Reson Med; 2019 Jan; 81(1):542-550. PubMed ID: 30229559
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Test-retest reliability and reproducibility of long-label pseudo-continuous arterial spin labeling.
    Lin T; Qu J; Zuo Z; Fan X; You H; Feng F
    Magn Reson Imaging; 2020 Nov; 73():111-117. PubMed ID: 32717203
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Robust kidney perfusion mapping in pediatric chronic kidney disease using single-shot 3D-GRASE ASL with optimized retrospective motion correction.
    Nery F; De Vita E; Clark CA; Gordon I; Thomas DL
    Magn Reson Med; 2019 May; 81(5):2972-2984. PubMed ID: 30536817
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multi-organ comparison of flow-based arterial spin labeling techniques: Spatially non-selective labeling for cerebral and renal perfusion imaging.
    Franklin SL; Bones IK; Harteveld AA; Hirschler L; van Stralen M; Qin Q; de Boer A; Hoogduin JM; Bos C; van Osch MJP; Schmid S
    Magn Reson Med; 2021 May; 85(5):2580-2594. PubMed ID: 33251644
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging.
    Shimizu K; Kosaka N; Fujiwara Y; Matsuda T; Yamamoto T; Tsuchida T; Tsuchiyama K; Oyama N; Kimura H
    Magn Reson Med Sci; 2017 Jan; 16(1):38-44. PubMed ID: 27170422
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Exploring label dynamics of velocity-selective arterial spin labeling in the kidney.
    Bones IK; Franklin SL; Harteveld AA; van Osch MJP; Schmid S; Hendrikse J; Moonen C; van Stralen M; Bos C
    Magn Reson Med; 2021 Jul; 86(1):131-142. PubMed ID: 33538350
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of Three-Dimensional Arterial Spin Labeling to Evaluate Renal Perfusion in Patients With Chronic Kidney Disease.
    Lu F; Yang J; Yang S; Bernd K; Fu C; Yang C; Xu H; Liu M; Zhan S; Wang C; Guo R; Wu Y
    J Magn Reson Imaging; 2021 Oct; 54(4):1152-1163. PubMed ID: 33769645
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Assessment of Renal Perfusion in Transplanted Kidney Patients Using Pseudo-Continuous Arterial Spin Labeling with Multiple Post-Labeling Delays.
    Ahn HS; Yu HC; Kwak HS; Park SH
    Eur J Radiol; 2020 Sep; 130():109200. PubMed ID: 32739781
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Diagnostic value of renal perfusion in patients with chronic kidney disease using 3D arterial spin labeling.
    Cai YZ; Li ZC; Zuo PL; Pfeuffer J; Li YM; Liu F; Liu RB
    J Magn Reson Imaging; 2017 Aug; 46(2):589-594. PubMed ID: 28181335
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multi-phase 3D arterial spin labeling brain MRI in assessing cerebral blood perfusion and arterial transit times in children at 3T.
    Hu HH; Rusin JA; Peng R; Shao X; Smith M; Krishnamurthy R; Selvaraj B; Wang DJJ
    Clin Imaging; 2019; 53():210-220. PubMed ID: 30439588
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Demonstration of velocity selective myocardial arterial spin labeling perfusion imaging in humans.
    Jao TR; Nayak KS
    Magn Reson Med; 2018 Jul; 80(1):272-278. PubMed ID: 29106745
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla.
    Gillis KA; McComb C; Foster JE; Taylor AH; Patel RK; Morris ST; Jardine AG; Schneider MP; Roditi GH; Delles C; Mark PB
    BMC Nephrol; 2014 Jan; 15():23. PubMed ID: 24484613
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fast imaging strategies for mouse kidney perfusion measurement with pseudocontinuous arterial spin labeling (pCASL) at ultra high magnetic field (11.75 tesla).
    Prevost VH; Girard OM; Callot V; Cozzone PJ; Duhamel G
    J Magn Reson Imaging; 2015 Oct; 42(4):999-1008. PubMed ID: 25712197
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of background suppression and retrospective realignment on free-breathing renal perfusion measurement using pseudo-continuous ASL.
    Taso M; Guidon A; Alsop DC
    Magn Reson Med; 2019 Apr; 81(4):2439-2449. PubMed ID: 30474312
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Motion-corrected multiparametric renal arterial spin labelling at 3 T: reproducibility and effect of vasodilator challenge.
    Shirvani S; Tokarczuk P; Statton B; Quinlan M; Berry A; Tomlinson J; Weale P; Kühn B; O'Regan DP
    Eur Radiol; 2019 Jan; 29(1):232-240. PubMed ID: 29992384
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volumetric Arterial Spin-labeled Perfusion Imaging of the Kidneys with a Three-dimensional Fast Spin Echo Acquisition.
    Robson PM; Madhuranthakam AJ; Smith MP; Sun MR; Dai W; Rofsky NM; Pedrosa I; Alsop DC
    Acad Radiol; 2016 Feb; 23(2):144-54. PubMed ID: 26521186
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantification of liver perfusion using multidelay pseudocontinuous arterial spin labeling.
    Pan X; Qian T; Fernandez-Seara MA; Smith RX; Li K; Ying K; Sung K; Wang DJ
    J Magn Reson Imaging; 2016 May; 43(5):1046-54. PubMed ID: 26445928
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accelerated 3D-GRASE imaging improves quantitative multiple post labeling delay arterial spin labeling.
    Boland M; Stirnberg R; Pracht ED; Kramme J; Viviani R; Stingl J; Stöcker T
    Magn Reson Med; 2018 Dec; 80(6):2475-2484. PubMed ID: 29770492
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.