These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 31815069)

  • 21. Volar locking plate fixation of distal radius fractures: use of an intra-operative 'carpal shoot through' view to identify dorsal compartment and distal radioulnar joint screw penetration.
    Marsland D; Hobbs CM; Sauvé PS
    Hand (N Y); 2014 Dec; 9(4):516-21. PubMed ID: 25414615
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Use of Computed Tomography in Determining the Occurrence of Dorsal and Intra-articular Screw Penetration in Volar Locking Plate Osteosynthesis of Distal Radius Fracture.
    Diong TW; Haflah NHM; Kassim AYM; Habshi SMIA; Shukur MH
    J Hand Surg Asian Pac Vol; 2018 Mar; 23(1):26-32. PubMed ID: 29409409
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparing Dorsal Tangential and Lateral Views of the Wrist for Detecting Dorsal Screw Penetration after Volar Plating of Distal Radius Fractures.
    Giugale JM; Fourman MS; Bielicka DL; Fowler JR
    Adv Orthop; 2017; 2017():1402517. PubMed ID: 28831312
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Distal Radius Skyline View: How to Prevent Dorsal Cortical Penetration.
    Taylor BC; Malarkey AR; Eschbaugh RL; Gentile J
    J Surg Orthop Adv; 2017 Nov; 26(3):183-186. PubMed ID: 29130881
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dorsal Screw Penetration With the Use of Volar Plating of Distal Radius Fractures: How Can You Best Detect?
    Hill BW; Shakir I; Cannada LK
    J Orthop Trauma; 2015 Oct; 29(10):e408-13. PubMed ID: 26402306
    [TBL] [Abstract][Full Text] [Related]  

  • 26. How effective is skyline view for avoiding dorsal cortex penetration in volar plate fixation of intra-articular and dorsal cortex comminuted distal radius fractures.
    Özbek EA; Ayanoğlu T; Armangil M
    Injury; 2019 Oct; 50(10):1684-1688. PubMed ID: 31371169
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Influence of training on dorsal tangential radiographic view to detect screw protrusion after anterior plating of the distal radius: a cadaveric study.
    Bergsma M; Obdeijn MC; Janssen SJ; Bain GI; Jaarsma RL; Doornberg JN
    J Hand Surg Eur Vol; 2020 Oct; 45(8):864-870. PubMed ID: 32041470
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Intraoperative evaluation of dorsal screw prominence after polyaxial volar plate fixation of distal radius fractures utilizing the Hoya view: a cadaveric study.
    Dolce D; Goodwin D; Ludwig M; Edwards S
    Hand (N Y); 2014 Dec; 9(4):511-5. PubMed ID: 25414614
    [TBL] [Abstract][Full Text] [Related]  

  • 29. What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian M; Simkovic P; Zamborsky R; Skoda A; Labas P
    Bratisl Lek Listy; 2019; 120(7):505-509. PubMed ID: 31602985
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration.
    Gurbuz Y; Kucuk L; Gunay H; Ozaksar K; Sugun TS; Bilge O
    Acta Orthop Traumatol Turc; 2017 Dec; 51(6):448-450. PubMed ID: 29092760
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A Prospective Observational Assessment of Unicortical Distal Screw Placement During Volar Plate Fixation of Distal Radius Fractures.
    Dardas AZ; Goldfarb CA; Boyer MI; Osei DA; Dy CJ; Calfee RP
    J Hand Surg Am; 2018 May; 43(5):448-454. PubMed ID: 29395586
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The utility of the fluoroscopic skyline view during volar locking plate fixation of distal radius fractures.
    Vaiss L; Ichihara S; Hendriks S; Taleb C; Liverneaux P; Facca S
    J Wrist Surg; 2014 Nov; 3(4):245-9. PubMed ID: 25364637
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Assessment of penetration of dorsal screws after fixation of the distal radius using ultrasound: cadaveric study.
    Williams D; Singh J; Heidari N; Ahmad M; Noorani A; Di Mascio L
    Ann R Coll Surg Engl; 2016 Feb; 98(2):138-42. PubMed ID: 26829667
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Pronated oblique view in assessing proximal scaphoid articular cannulated screw penetration.
    Kim RY; Lijten EC; Strauch RJ
    J Hand Surg Am; 2008 Oct; 33(8):1274-7. PubMed ID: 18929188
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Volar versus dorsal plating in the management of intra-articular distal radius fractures.
    Ruch DS; Papadonikolakis A
    J Hand Surg Am; 2006 Jan; 31(1):9-16. PubMed ID: 16443097
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Does skyline view prevent extensor tendon pathologies during volar plating of distal radius? An ultrasonographic evaluation.
    Yüksel S; Güröz AN; Öztürk A; Bilgetekin YG; Ersan Ö; Ceylan AH
    Jt Dis Relat Surg; 2023 Apr; 34(2):331-337. PubMed ID: 37462636
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Ultrasound Imaging Improves Identification of Prominent Hardware in the Surgical Treatment of Distal Radius Fractures: A Cadaveric and Prospective Clinical Study.
    Watchmaker JD; Daley RA; Watchmaker GP; Grindel SI
    J Wrist Surg; 2016 Mar; 5(1):36-41. PubMed ID: 26855834
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Anatomic tilt x-rays of the distal radius: an ex vivo analysis of surgical fixation.
    Boyer MI; Korcek KJ; Gelberman RH; Gilula LA; Ditsios K; Evanoff BA
    J Hand Surg Am; 2004 Jan; 29(1):116-22. PubMed ID: 14751114
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vivo confirmation of the reliability of the dorsal tangential view of the wrist.
    Kiyak G
    Hand Surg Rehabil; 2018 Feb; 37(1):56-59. PubMed ID: 29229540
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Detection of penetration of the dorsal cortex by epiphyseal screws of distal radius volar plates: Anatomical study comparing ultrasound and fluoroscopy.
    Vernet P; Durry A; Nicolau X; D'Ambrosio A; Collinet A; Botero Salazar S; Liverneaux P; Hidalgo Diaz JJ
    Orthop Traumatol Surg Res; 2017 Oct; 103(6):911-913. PubMed ID: 28416461
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.