These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
151 related articles for article (PubMed ID: 31819337)
1. Pilot study: Internally cooled orthopedic drills - standard sterilization is not enough? Bruketa T; Augustin G; Pintarić S; Šeol-Martinec B; Dobrić I; Bakota B Acta Clin Croat; 2019 Jun; 58(2):379-385. PubMed ID: 31819337 [TBL] [Abstract][Full Text] [Related]
2. Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill. Augustin G; Davila S; Udilljak T; Staroveski T; Brezak D; Babic S Int Orthop; 2012 Jul; 36(7):1449-56. PubMed ID: 22290154 [TBL] [Abstract][Full Text] [Related]
3. Is retained bone debris in cannulated orthopedic instruments sterile after autoclaving? Smith K; Araoye I; Gilbert S; Waites K; Camins B; Conklin M; Ponce B Am J Infect Control; 2018 Sep; 46(9):1009-1013. PubMed ID: 29661627 [TBL] [Abstract][Full Text] [Related]
5. Distribution of coolant during drilling with open type internally cooled medical steel drill. Bruketa T; Augustin G; Staroveški T; Klaić M; Brezak D; Capak H; Dobrić I Injury; 2021 Sep; 52 Suppl 5():S32-S37. PubMed ID: 32958340 [TBL] [Abstract][Full Text] [Related]
6. Design and performance analysis of low damage anti-skid crescent drills for bone drilling. Zhao J; Wu D; Wu X; Zhang Z; Wen Z; Liu S J Orthop Surg Res; 2024 Aug; 19(1):489. PubMed ID: 39153973 [TBL] [Abstract][Full Text] [Related]
7. Comparison of cortical bone drilling induced heat production among common drilling tools. Palmisano AC; Tai BL; Belmont B; Irwin TA; Shih A; Holmes JR J Orthop Trauma; 2015 May; 29(5):e188-93. PubMed ID: 25233167 [TBL] [Abstract][Full Text] [Related]
8. Heat production by 3 implant drill systems after repeated drilling and sterilization. Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899 [TBL] [Abstract][Full Text] [Related]
9. Improved accuracy of navigated drilling using a drill alignment device. Kendoff D; Citak M; Gardner MJ; Stübig T; Krettek C; Hüfner T J Orthop Res; 2007 Jul; 25(7):951-7. PubMed ID: 17415775 [TBL] [Abstract][Full Text] [Related]
10. Thermal damage of osteocytes during pig bone drilling: an in vivo comparative study of currently available and modified drills. Kanaya H; Enokida M; Uehara K; Ueki M; Nagashima H Arch Orthop Trauma Surg; 2019 Nov; 139(11):1599-1605. PubMed ID: 31289845 [TBL] [Abstract][Full Text] [Related]
11. Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: A comparative in vitro study in a standardised bovine bone model. Tur D; Giannis K; Unger E; Mittlböck M; Rausch-Fan X; Strbac GD Clin Oral Implants Res; 2021 Feb; 32(2):154-166. PubMed ID: 33220104 [TBL] [Abstract][Full Text] [Related]
13. Recommended Drilling Parameters of Tungsten Carbide Round Drills for the Most Optimal Bone Removals in Oral Surgery. Szalma J; Klein O; Lovász BV; Lempel E; Jeges S; Olasz L Biomed Res Int; 2018; 2018():3108581. PubMed ID: 30581849 [TBL] [Abstract][Full Text] [Related]
14. Compressed-air power tools in orthopaedic surgery: exhaust air is a potential source of contamination. Sagi HC; DiPasquale T; Sanders R; Herscovici D J Orthop Trauma; 2002; 16(10):696-700. PubMed ID: 12439192 [TBL] [Abstract][Full Text] [Related]
15. Drill wear monitoring in cortical bone drilling. Staroveski T; Brezak D; Udiljak T Med Eng Phys; 2015 Jun; 37(6):560-6. PubMed ID: 25922212 [TBL] [Abstract][Full Text] [Related]
16. 3-Fluted orthopaedic drills exhibit superior bending stiffness to their 2-fluted rivals: clinical implications for targeting ability and the incidence of drill-bit failure. Bertollo N; Gothelf TK; Walsh WR Injury; 2008 Jul; 39(7):734-41. PubMed ID: 18490018 [TBL] [Abstract][Full Text] [Related]
17. Effect of drill quality on biological damage in bone drilling. Alam K; Qamar SZ; Iqbal M; Piya S; Al-Kindi M; Qureshi A; Al-Ghaithi A; Al-Sumri B; Silberschmidt VV Sci Rep; 2023 Apr; 13(1):6234. PubMed ID: 37069203 [TBL] [Abstract][Full Text] [Related]
18. Effects of sterilization procedures on the cutting efficiency of stainless steel and carbon steel Gates Glidden drills. Zettlemoyer TL; Goerig AC; Nagy WW; Grabow W J Endod; 1989 Nov; 15(11):522-5. PubMed ID: 2517952 [TBL] [Abstract][Full Text] [Related]
19. A comparison of the thermal properties of 2- and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model. Bertollo N; Milne HR; Ellis LP; Stephens PC; Gillies RM; Walsh WR Clin Biomech (Bristol); 2010 Jul; 25(6):613-7. PubMed ID: 20359798 [TBL] [Abstract][Full Text] [Related]
20. The Effects of Liquid Disinfection and Heat Sterilization Processes on Implant Drill Roughness: Energy Dispersion X-ray Microanalysis and Infrared Thermography. Scarano A; Petrini M; Mastrangelo F; Noumbissi S; Lorusso F J Clin Med; 2020 Apr; 9(4):. PubMed ID: 32260343 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]