BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 31830630)

  • 21. Rapid 3D breath-hold MR cholangiopancreatography using deep learning-constrained compressed sensing reconstruction.
    Zhang Y; Peng W; Xiao Y; Ming Y; Ma K; Hu S; Zeng W; Zeng L; Liang Z; Zhang X; Xia C; Li Z
    Eur Radiol; 2023 Apr; 33(4):2500-2509. PubMed ID: 36355200
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Navigator-triggered and breath-hold 3D MRCP using compressed sensing: image quality and method selection factor assessment.
    Morimoto D; Hyodo T; Kamata K; Kadoba T; Itoh M; Fukushima H; Chiba Y; Takenaka M; Mochizuki T; Ueda Y; Miyagoshi K; Kudo M; Ishii K
    Abdom Radiol (NY); 2020 Oct; 45(10):3081-3091. PubMed ID: 31925493
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Magnetic resonance cholangiopancreatography with compressed sensing at 1.5 T: clinical application for the evaluation of branch duct IPMN of the pancreas.
    Henninger B; Steurer M; Plaikner M; Weiland E; Jaschke W; Kremser C
    Eur Radiol; 2020 Nov; 30(11):6014-6021. PubMed ID: 32556465
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optimized Breath-Hold Compressed-Sensing 3D MR Cholangiopancreatography at 3T: Image Quality Analysis and Clinical Feasibility Assessment.
    Song JS; Kim SH; Kuehn B; Paek MY
    Diagnostics (Basel); 2020 Jun; 10(6):. PubMed ID: 32517113
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Three-dimensional MR Cholangiopancreatography in a Breath Hold with Sparsity-based Reconstruction of Highly Undersampled Data.
    Chandarana H; Doshi AM; Shanbhogue A; Babb JS; Bruno MT; Zhao T; Raithel E; Zenge MO; Li G; Otazo R
    Radiology; 2016 Aug; 280(2):585-94. PubMed ID: 26982678
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Clinical usefulness of free-breathing navigator-triggered 3D MRCP in non-cooperative patients: comparison with conventional breath-hold 2D MRCP.
    Kim JH; Hong SS; Eun HW; Han JK; Choi BI
    Eur J Radiol; 2012 Apr; 81(4):e513-8. PubMed ID: 21700409
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluating the Quality of Optimal MRCP Image Using RT-2D-Compressed SENSE(CS)Turbo Spin Echo: Comparing Respiratory Triggering(RT)-2D-SENSE Turbo Spin Echo and Breath Hold-2D-Single-Shot Turbo Spin Echo.
    Goo EH; Kim SS
    Tomography; 2022 May; 8(3):1374-1385. PubMed ID: 35645397
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Clinical Feasibility of Abbreviated Magnetic Resonance With Breath-Hold 3-Dimensional Magnetic Resonance Cholangiopancreatography for Surveillance of Pancreatic Intraductal Papillary Mucinous Neoplasm.
    Kang HJ; Lee DH; Lee JM; Yoo J; Weiland E; Kim E; Son Y
    Invest Radiol; 2020 May; 55(5):262-269. PubMed ID: 32073419
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of Compressed Sensing and Gradient and Spin-Echo in Breath-Hold 3D MR Cholangiopancreatography: Qualitative and Quantitative Analysis.
    Jang W; Song JS; Kim SH; Yang JD
    Diagnostics (Basel); 2021 Apr; 11(4):. PubMed ID: 33915832
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison between Conventional Breath-hold and Respiratory-triggered Magnetic Resonance Cholangiopancreatography with and without Compressed Sensing: Cross-sectional Study.
    Kim Y; Lee ES; Park HJ; Park SB; Kuehn B; Sung JK; Lim Y; Kim C
    Curr Med Imaging; 2023 Mar; ():. PubMed ID: 37018526
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Patient-adapted respiratory training: Effect on navigator-triggered 3D MRCP in painful pancreatobiliary disorders.
    Zhu L; Sun ZY; Xue HD; Liu D; Qian TY; Asbach P; Jin ZY
    Magn Reson Imaging; 2018 Jan; 45():43-50. PubMed ID: 28963048
    [TBL] [Abstract][Full Text] [Related]  

  • 32. How reliable is MRCP with an SS-FSE sequence at 3.0 T: comparison between SS-FSE BH and 3D-FSE BH ASSET sequences.
    Lavdas E; Vlychou M; Arikidis N; Kapsalaki E; Roka V; Arvanitis DL; Fezoulidis I; Vassiou K
    Clin Imaging; 2013; 37(4):697-703. PubMed ID: 23522790
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Rapid 3D navigator-triggered MR cholangiopancreatography with SPACE sequence at 3T: only one-third acquisition time of conventional 3D SPACE navigator-triggered MRCP.
    Sun B; Chen Z; Duan Q; Xue Y; Zheng E; He Y; Lin L; Li G; Zhang Z
    Abdom Radiol (NY); 2020 Jan; 45(1):134-140. PubMed ID: 31781898
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Comparison between gradient and spin-echo (GRASE) and compressed sensing sequences for single breath-hold three-dimensional magnetic resonance cholangiopancreatography in patients with T
    Morimoto-Ishikawa D; Hyodo T; Takenaka M; Matsukubo Y; Numoto I; Itoh M; Ohmi M; Kamata K; Ueda Y; Wakana M; Kudo M; Saito S; Ishii K
    Eur J Radiol; 2022 May; 150():110279. PubMed ID: 35364450
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Clinical Feasibility of Free-Breathing Dynamic T1-Weighted Imaging With Gadoxetic Acid-Enhanced Liver Magnetic Resonance Imaging Using a Combination of Variable Density Sampling and Compressed Sensing.
    Yoon JH; Yu MH; Chang W; Park JY; Nickel MD; Son Y; Kiefer B; Lee JM
    Invest Radiol; 2017 Oct; 52(10):596-604. PubMed ID: 28492418
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Feasibility of 3D navigator-triggered magnetic resonance cholangiopancreatography with combined parallel imaging and compressed sensing reconstruction at 3T.
    Seo N; Park MS; Han K; Kim D; King KF; Choi JY; Kim H; Kim HJ; Lee M; Bae H; Kim MJ
    J Magn Reson Imaging; 2017 Nov; 46(5):1289-1297. PubMed ID: 28295827
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Clinical impact of 3-dimensional balanced turbo-field-echo magnetic resonance cholangiopancreatography at 3 T: prospective intraindividual comparison with 3-dimensional turbo-spin-echo magnetic resonance cholangiopancreatography.
    Itatani R; Namimoto T; Takaoka H; Katahira K; Noda S; Toyonari N; Yamashita Y
    J Comput Assist Tomogr; 2015; 39(1):19-24. PubMed ID: 25299796
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Parallel imaging improves the image quality and duct visibility of breathhold two-dimensional thick-slab MR cholangiopancreatography.
    Lee JH; Lee SS; Kim JY; Kim IS; Byun JH; Park SH; Lee MG
    J Magn Reson Imaging; 2014 Feb; 39(2):269-75. PubMed ID: 23596083
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Two-dimensional XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration.
    Piekarski E; Chitiboi T; Ramb R; Latson LA; Bhatla P; Feng L; Axel L
    MAGMA; 2018 Feb; 31(1):49-59. PubMed ID: 29067539
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Abbreviated Magnetic Resonance Imaging With Breath-Hold Three-Dimensional Magnetic Resonance Cholangiopancreatography: Assessment of Malignant Risk of Pancreatic Intraductal Papillary Mucinous Neoplasm.
    Yoo J; Min JH; Lee DH; Hur BY; Kim SW; Kim E
    J Magn Reson Imaging; 2021 Oct; 54(4):1177-1186. PubMed ID: 33779024
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.