BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

267 related articles for article (PubMed ID: 31833893)

  • 41. Reducing donor-site complications in DIEP flap breast reconstruction with closed incisional negative pressure therapy: A cost-benefit analysis.
    Munro SP; Dearden A; Joseph M; O'Donoghue JM
    J Plast Reconstr Aesthet Surg; 2023 Mar; 78():13-18. PubMed ID: 36739647
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Randomized clinical trial investigating the use of drains and fibrin sealant following surgery for breast cancer.
    Jain PK; Sowdi R; Anderson AD; MacFie J
    Br J Surg; 2004 Jan; 91(1):54-60. PubMed ID: 14716794
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The Effect of Drains and Compressive Garments Versus Progressive Tensioning Sutures on Seroma Formation in Abdominoplasty.
    Brown T; Murphy K; Murphy T
    Aesthetic Plast Surg; 2023 Oct; 47(5):1905-1910. PubMed ID: 36596923
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Prevention of Seroma Formation Following Abdominoplasty: A Systematic Review and Meta-Analysis.
    Seretis K; Goulis D; Demiri EC; Lykoudis EG
    Aesthet Surg J; 2017 Mar; 37(3):316-323. PubMed ID: 28158391
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Effects of Quilting Suture Interval on Donor Site Seromas After Breast Reconstruction With Latissimus Dorsi Muscle Flap: A Randomized Trial.
    Lee J; Bae Y; Jung JH; Kim WW; Hwang SO; Kwon TJ; Chung JH; Park HY; Lee S; Jung Y
    Clin Breast Cancer; 2016 Dec; 16(6):e159-e164. PubMed ID: 27364307
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Fibrin sealant decreases postoperative drainage in immediate breast reconstruction by deep inferior epigastric perforator flap after mastectomy with axillary dissection.
    Hivelin M; Heusse JL; Matar N; Lepage C; Lantieri L
    Microsurgery; 2011 Jan; 31(1):18-25. PubMed ID: 20878653
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Progressive tension sutures in the prevention of postabdominoplasty seroma: a prospective, randomized, double-blind clinical trial.
    Andrades P; Prado A; Danilla S; Guerra C; Benitez S; Sepulveda S; Sciarraffia C; De Carolis V
    Plast Reconstr Surg; 2007 Sep; 120(4):935-946. PubMed ID: 17805122
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Fibrin Sealant Artiss Compared to Progressive Tension Sutures With Stratafix in the Management of Wound Drainage Following Post-Bariatric Body-Contouring Surgery.
    Zeplin PH; Langer S; Schwarzenberger S; Spindler N
    Plast Surg (Oakv); 2021 Aug; 29(3):146-152. PubMed ID: 34568229
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Randomized Single-Center Study of Effectiveness and Safety of a Resorbable Lysine-Based Urethane Adhesive for a Drain-Free Closure of the Abdominal Donor Site in a DIEP Flap Breast Reconstruction Procedure.
    Fertsch S; Michalak M; Andree C; Munder B; Hagouan M; Schulz T; Stambera P; Steammler K; Grueter L; Kornetka J; Wolter A
    J Invest Surg; 2022 Jun; 35(6):1404-1414. PubMed ID: 35263551
    [TBL] [Abstract][Full Text] [Related]  

  • 50. No-drain abdominoplasty with progressive tension sutures.
    Pollock TA; Pollock H
    Clin Plast Surg; 2010 Jul; 37(3):515-24. PubMed ID: 20624550
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Utility of autologous fibrin glue in the donor site of free abdominal flap for breast reconstruction: A randomized controlled study.
    Tokumoto H; Akita S; Kubota Y; Mitsukawa N
    J Plast Reconstr Aesthet Surg; 2021 Nov; 74(11):2870-2875. PubMed ID: 33992561
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Closed incision negative pressure therapy following abdominoplasty after breast reconstruction with deep inferior epigastric perforator flaps.
    Fang CL; Changchien CH; Chen MS; Hsu CH; Tsai CB
    Int Wound J; 2020 Apr; 17(2):326-331. PubMed ID: 31777164
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Increased Production of Abdominal Donor Site Fluid Following Microsurgical Breast Reconstruction With Superficial Inferior Epigastric Artery Versus Deep Inferior Epigastric Artery Perforator Flaps.
    Carslaw CH; Samudrala H; Kerrison J; Brooker JE; Rabey NG; Malata CM
    Cureus; 2023 May; 15(5):e38942. PubMed ID: 37313097
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Reducing seroma in outpatient abdominoplasty: analysis of 516 consecutive cases.
    Antonetti JW; Antonetti AR
    Aesthet Surg J; 2010; 30(3):418-25. PubMed ID: 20601568
    [TBL] [Abstract][Full Text] [Related]  

  • 55. The effect of fibrin sealant on the prevention of seroma formation after postbariatric abdominoplasty.
    Lee JC; Teitelbaum J; Shajan JK; Naram A; Chao J
    Can J Plast Surg; 2012; 20(3):178-80. PubMed ID: 23997585
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Do progressive tension sutures really decrease complications in abdominoplasty?
    Khan S; Teotia SS; Mullis WF; Jacobs WE; Beasley ME; Smith KL; Eaves FF; Finical SJ; Watterson PA
    Ann Plast Surg; 2006 Jan; 56(1):14-20; discussion 20-1. PubMed ID: 16374089
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The effects of low-thrombin fibrin sealant on wound serous drainage, seroma formation and length of postoperative stay in patients undergoing axillary node dissection for breast cancer. A randomized controlled trial.
    Benevento R; Santoriello A; Pellino G; Sciaudone G; Candilio G; De Fatico GS; Selvaggi F; ; Canonico S
    Int J Surg; 2014 Nov; 12(11):1210-5. PubMed ID: 25462702
    [TBL] [Abstract][Full Text] [Related]  

  • 58. No-drain Technique in Abdominal Closure for Breast Reconstruction: Lower Complication Rate, Shorter Hospitalization Stay.
    Chan SLS; Rutherford C; Kong TY
    Plast Reconstr Surg Glob Open; 2020 Feb; 8(2):e2637. PubMed ID: 32309084
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Efficacy of Low Power, Pure Cut Mode of Monopolar Electrosurgery and Quilting Sutures for Preventing Seroma Formation After Latissimus Dorsi Myocutaneous Flap Harvest.
    Tashima H; Tomita K; Kurita T; Kubo T
    Ann Plast Surg; 2021 Mar; 86(3):265-267. PubMed ID: 33555680
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Safety of Drainless Donor Closure in DIEP Flap-Based Breast Reconstruction: A Prospective Analysis Using Ultrasound.
    Kim J; Lee KT; Mun GH
    J Reconstr Microsurg; 2024 Feb; 40(2):123-131. PubMed ID: 37137340
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.