241 related articles for article (PubMed ID: 31837022)
1. Automated 3D geometry segmentation of the healthy and diseased carotid artery in free-hand, probe tracked ultrasound images.
de Ruijter J; van Sambeek M; van de Vosse F; Lopata R
Med Phys; 2020 Mar; 47(3):1034-1047. PubMed ID: 31837022
[TBL] [Abstract][Full Text] [Related]
2. Semiautomatic segmentation of atherosclerotic carotid artery wall volume using 3D ultrasound imaging.
Hossain MM; AlMuhanna K; Zhao L; Lal BK; Sikdar S
Med Phys; 2015 Apr; 42(4):2029-43. PubMed ID: 25832093
[TBL] [Abstract][Full Text] [Related]
3. Three-dimensional segmentation of three-dimensional ultrasound carotid atherosclerosis using sparse field level sets.
Ukwatta E; Yuan J; Buchanan D; Chiu B; Awad J; Qiu W; Parraga G; Fenster A
Med Phys; 2013 May; 40(5):052903. PubMed ID: 23635296
[TBL] [Abstract][Full Text] [Related]
4. Three-dimensional ultrasound of carotid atherosclerosis: semiautomated segmentation using a level set-based method.
Ukwatta E; Awad J; Ward AD; Buchanan D; Samarabandu J; Parraga G; Fenster A
Med Phys; 2011 May; 38(5):2479-93. PubMed ID: 21776783
[TBL] [Abstract][Full Text] [Related]
5. Carotid plaque segmentation from three-dimensional ultrasound images by direct three-dimensional sparse field level-set optimization.
Cheng J; Chen Y; Yu Y; Chiu B
Comput Biol Med; 2018 Mar; 94():27-40. PubMed ID: 29407996
[TBL] [Abstract][Full Text] [Related]
6. Freehand three-dimensional ultrasound imaging of carotid artery using motion tracking technology.
Chung SW; Shih CC; Huang CC
Ultrasonics; 2017 Feb; 74():11-20. PubMed ID: 27721196
[TBL] [Abstract][Full Text] [Related]
7. Semiautomatic quantification of carotid plaque volume with three-dimensional ultrasound imaging.
Khan AA; Koudelka C; Goldstein C; Zhao L; Yokemick J; Dux M; Sikdar S; Lal BK
J Vasc Surg; 2017 May; 65(5):1407-1417. PubMed ID: 28274755
[TBL] [Abstract][Full Text] [Related]
8. Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound.
Carvalho DD; Klein S; Akkus Z; ten Kate GL; Schinkel AF; Bosch JG; van der Lugt A; Niessen WJ
Int J Comput Assist Radiol Surg; 2012 Mar; 7(2):207-15. PubMed ID: 21713367
[TBL] [Abstract][Full Text] [Related]
9. Carotid artery lumen segmentation in 3D free-hand ultrasound images using surface graph cuts.
Lorza AM; Carvalho DD; Petersen J; van Dijk AC; van der Lugt A; Niessen WJ; Klein S; de Bruijne M
Med Image Comput Comput Assist Interv; 2013; 16(Pt 2):542-9. PubMed ID: 24579183
[TBL] [Abstract][Full Text] [Related]
10. Quantification of carotid vessel wall and plaque thickness change using 3D ultrasound images.
Chiu B; Egger M; Spence JD; Parraga G; Fenster A
Med Phys; 2008 Aug; 35(8):3691-710. PubMed ID: 18777929
[TBL] [Abstract][Full Text] [Related]
11. Deep learning-based carotid media-adventitia and lumen-intima boundary segmentation from three-dimensional ultrasound images.
Zhou R; Fenster A; Xia Y; Spence JD; Ding M
Med Phys; 2019 Jul; 46(7):3180-3193. PubMed ID: 31071228
[TBL] [Abstract][Full Text] [Related]
12. Segmentation of common and internal carotid arteries from 3D ultrasound images based on adaptive triple loss.
Jiang M; Zhao Y; Chiu B
Med Phys; 2021 Sep; 48(9):5096-5114. PubMed ID: 34309866
[TBL] [Abstract][Full Text] [Related]
13. Automated registration of multispectral MR vessel wall images of the carotid artery.
van 't Klooster R; Staring M; Klein S; Kwee RM; Kooi ME; Reiber JH; Lelieveldt BP; van der Geest RJ
Med Phys; 2013 Dec; 40(12):121904. PubMed ID: 24320515
[TBL] [Abstract][Full Text] [Related]
14. Learning-based automated segmentation of the carotid artery vessel wall in dual-sequence MRI using subdivision surface fitting.
Gao S; van 't Klooster R; Kitslaar PH; Coolen BF; van den Berg AM; Smits LP; Shahzad R; Shamonin DP; de Koning PJH; Nederveen AJ; van der Geest RJ
Med Phys; 2017 Oct; 44(10):5244-5259. PubMed ID: 28715090
[TBL] [Abstract][Full Text] [Related]
15. Fast segmentation of the femoral arteries from 3D MR images: A tool for rapid assessment of peripheral arterial disease.
Chen W; Xu J; Chiu B
Med Phys; 2015 May; 42(5):2431-48. PubMed ID: 25979037
[TBL] [Abstract][Full Text] [Related]
16. An integrated system for the segmentation of atherosclerotic carotid plaque ultrasound video.
Loizou C; Petroudi S; Pantziaris M; Nicolaides A; Pattichis C
IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jan; 61(1):86-101. PubMed ID: 24402898
[TBL] [Abstract][Full Text] [Related]
17. A Voxel-Based Fully Convolution Network and Continuous Max-Flow for Carotid Vessel-Wall-Volume Segmentation From 3D Ultrasound Images.
Zhou R; Guo F; Azarpazhooh MR; Spence JD; Ukwatta E; Ding M; Fenster A
IEEE Trans Med Imaging; 2020 Sep; 39(9):2844-2855. PubMed ID: 32142426
[TBL] [Abstract][Full Text] [Related]
18. State-of-the-art review on automated lumen and adventitial border delineation and its measurements in carotid ultrasound.
Kumar PK; Araki T; Rajan J; Laird JR; Nicolaides A; Suri JS;
Comput Methods Programs Biomed; 2018 Sep; 163():155-168. PubMed ID: 30119850
[TBL] [Abstract][Full Text] [Related]
19. 3D reconstruction of a carotid bifurcation from 2D transversal ultrasound images.
Yeom E; Nam KH; Jin C; Paeng DG; Lee SJ
Ultrasonics; 2014 Dec; 54(8):2184-92. PubMed ID: 24965564
[TBL] [Abstract][Full Text] [Related]
20. Single sweep three-dimensional carotid ultrasound: reproducibility in plaque and artery volume measurements.
Kalashyan H; Shuaib A; Gibson PH; Romanchuk H; Saqqur M; Khan K; Osborne J; Becher H
Atherosclerosis; 2014 Feb; 232(2):397-402. PubMed ID: 24468154
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]