BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 31837935)

  • 1. How to convert a square knot or surgeon's knot into a sliding knot and an assessment of their sliding and re-locking properties?
    Zhang W; Wu X
    Surgeon; 2020 Dec; 18(6):327-334. PubMed ID: 31837935
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Knot Security- How is it Affected by Suture Technique, Material, Size, and Number of Throws?
    Silver E; Wu R; Grady J; Song L
    J Oral Maxillofac Surg; 2016 Jul; 74(7):1304-12. PubMed ID: 26979258
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Arthroscopic knots: determining the optimal balance of loop security and knot security.
    Lo IK; Burkhart SS; Chan KC; Athanasiou K
    Arthroscopy; 2004 May; 20(5):489-502. PubMed ID: 15122139
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanical performance of square knots and sliding knots in surgery: comparative study.
    van Rijssel EJ; Trimbos JB; Booster MH
    Am J Obstet Gynecol; 1990 Jan; 162(1):93-7. PubMed ID: 2154104
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Initial loop and knot security of arthroscopic knots using high-strength sutures.
    Shah MR; Strauss EJ; Kaplan K; Jazrawi L; Rosen J
    Arthroscopy; 2007 Aug; 23(8):884-8. PubMed ID: 17681211
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimization of the racking hitch knot: how many half hitches and which suture material provide the greatest security?
    Kelly JD; Vaishnav S; Saunders BM; Schrumpf MA
    Clin Orthop Relat Res; 2014 Jun; 472(6):1930-5. PubMed ID: 24515401
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice.
    Avoine X; Lussier B; Brailovski V; Inaekyan K; Beauchamp G
    Can J Vet Res; 2016 Apr; 80(2):162-70. PubMed ID: 27127344
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In Vitro Evaluation of the Size, Knot Holding Capacity, and Knot Security of the Forwarder Knot Compared to Square and Surgeon's Knots Using Large Gauge Suture.
    Gillen AM; Munsterman AS; Hanson RR
    Vet Surg; 2016 Nov; 45(8):1034-1040. PubMed ID: 27685840
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tensile strength of a surgeon's or a square knot.
    Muffly TM; Boyce J; Kieweg SL; Bonham AJ
    J Surg Educ; 2010; 67(4):222-6. PubMed ID: 20816357
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimal configuration of arthroscopic sliding knots backed up with multiple half-hitches.
    Jo CH; Lee JH; Kang SB; Lee JH; Han HS; Bae TS; Choi K; Lee C; Lee MC; Yoon KS
    Knee Surg Sports Traumatol Arthrosc; 2008 Aug; 16(8):787-93. PubMed ID: 18320170
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of four sliding knots and three high-strength sutures: Loop security is much different between each combination.
    Kuptniratsaikul S; Weerawit P; Kongrukgreatiyos K; Promsang T
    J Orthop Res; 2016 Oct; 34(10):1804-1807. PubMed ID: 26861812
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The best knot and suture configurations for high-strength suture material. An in vitro biomechanical study.
    Meyer DC; Bachmann E; Lädermann A; Lajtai G; Jentzsch T
    Orthop Traumatol Surg Res; 2018 Dec; 104(8):1277-1282. PubMed ID: 30327262
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In Vitro Evaluation of the Aberdeen Knot for Continuous Suture Patterns with Large Gauge Suture.
    Gillen AM; Munsterman AS; Farag R; Coleridge MO; Reid Hanson R
    Vet Surg; 2016 Oct; 45(7):955-961. PubMed ID: 27604910
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro holding security of four friction knots of monofilament or multifilament suture used as a first throw for vascular ligation.
    Tremolada G; Hazenfield KM; Smeak DD
    Am J Vet Res; 2020 Oct; 81(10):821-826. PubMed ID: 32969726
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Knot properties of alternating sliding knots with different patterns in comparison to alternating and simple sliding knots.
    Babetty Z; Sümer A; Altintaş S
    J Am Coll Surg; 1998 Apr; 186(4):485-9. PubMed ID: 9544964
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Arthroscopic suture material and knot type: an updated biomechanical analysis.
    Swan KG; Baldini T; McCarty EC
    Am J Sports Med; 2009 Aug; 37(8):1578-85. PubMed ID: 19470946
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of knotting method on the structural properties of large diameter nonabsorbable monofilament sutures.
    Huber DJ; Egger EL; James SP
    Vet Surg; 1999; 28(4):260-7. PubMed ID: 10424706
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Security of knots tied with ethibond, fiberwire, orthocord, or ultrabraid.
    Ilahi OA; Younas SA; Ho DM; Noble PC
    Am J Sports Med; 2008 Dec; 36(12):2407-14. PubMed ID: 18827068
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Tensile Properties and Knot Security of Surgical Sutures: An In Vitro Mechanical Study.
    Wang M; Xiang X; Wang Y; Ren Y; Yang L; Zhang Y
    J Oral Maxillofac Surg; 2022 Jul; 80(7):1215-1222. PubMed ID: 35452601
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of sliding knots in monofilament and multifilament suture material.
    Trimbos JB; Van Rijssel EJ; Klopper PJ
    Obstet Gynecol; 1986 Sep; 68(3):425-30. PubMed ID: 3016627
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.